Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HAL 600-SSENSOR CURRENT HALL 600A AC/DC |
28 |
|
|
HAL | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 600A | 1 | Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | ±15V | 3µs | 25mA | -25°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
AT 20 B5SENSOR CURRENT XFMR 20A AC |
129 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0V ~ 5V | - | 50/60Hz | ±0.5% | ±1.5% | Self Powered | 300ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4644X052CURRENT SENSOR, 500A, PRI OPEN, |
81 |
|
|
- | Module, Single Pass Through | Box | Active | - | - | 500A | 1 | Ratiometric, Current | - | DC ~ 50kHz | ±0.1% | ±0.5% | 14.75V ~ 15.25V | - | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
T60404N4644X054CURRENT SENSOR, 700A, PRI OPEN, |
199 |
|
|
- | Module, Single Pass Through | Box | Active | - | - | 700A | 1 | Ratiometric, Current | - | DC ~ 50kHz | ±0.1% | ±0.5% | 14.75V ~ 15.25V | 1µs | 45mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
CSNV700N-354CSNV700 CURRENT SENSOR |
142 |
|
|
CSNV700 | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate | 700A | 1 | CAN Bus | - | - | ±0.1% | ±0.5% | 7V ~ 18V | - | 180mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 600-SSENSOR CURRENT HALL 600A AC/DC |
38 |
|
|
HAX | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AT 100 B10SENSOR CURRENT XFMR 100A AC |
284 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 0V ~ 10V | - | 50/60Hz | ±0.5% | ±1.5% | Self Powered | 300ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
CAB 1500-000AUTOMOTIVE GRADE CURRENT SENSOR |
62 |
|
|
CAB | Module, Single Pass Through | Box | Active | DC | Flux Gate | 1500A | 1 | CAN Bus | - | DC ~ 20Hz | ±0.1% | ±0.5% | 9V ~ 16V | - | 1.4A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CAB 1500-001AUTOMOTIVE GRADE CURRENT SENSOR |
61 |
|
|
CAB | Module, Single Pass Through | Box | Active | DC | Flux Gate | 1500A | 1 | CAN Bus | - | DC ~ 20Hz | ±0.1% | ±0.5% | 9V ~ 16V | - | 1.4A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
APR 200 B10SENSOR CURRENT 100A, 150A, 200A |
47 |
|
|
APR | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
APR 100 B10SENSOR CURRENT 50A, 75A, 100A |
34 |
|
|
APR | Module | Bulk | Active | AC | Transformer w/Conditioning | 50A, 75A, 100A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
CAB-SF 1500-006TRANSDUCER |
57 |
|
|
CAB | Module, Single Pass Through | Bulk | Active | DC | Flux Gate | 1500A | 1 | CAN Bus | - | DC ~ 20Hz | ±0.1% | ±0.5% | 9V ~ 16V | - | 1.4A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
SSD-250A-C100A - 24BIT ISOLATED SHUNT CUR |
53 |
|
|
SSD | Module | Bulk | Active | DC | Current Sensor | 250A | 1 | CAN Bus | - | - | ±0.1% | ±0.1% | 5V ~ 60V | - | 55mA (Typ) | -40°C ~ 115°C | - | - | Bidirectional | Chassis Mount | - |
|
SSD-500A-R100A - 24BIT ISOLATED SHUNT CUR |
30 |
|
|
SSD | Module | Bulk | Active | DC | Current Sensor | 500A | 1 | RS485 | - | - | ±0.1% | ±0.1% | 24V ~ 60V | - | 15mA (Typ) | -40°C ~ 115°C | - | - | Bidirectional | Chassis Mount | - |
|
MNS2-9-W2-CM-150ALTA WIRELESS AC CURRENT METER - |
34 |
|
|
- | IoT Finished Device | Bulk | Active | AC | Current Sensor | 150A | - | - | - | 50Hz ~ 100Hz | - | ±2% | 2V ~ 3.8V | - | 22.6mA | -18°C ~ 55°C | - | - | - | Chassis Mount | - |
|
DHR 100 C5SENSOR CURRENT HALL 100A AC/DC |
27 |
|
|
DHR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, 0V ~ 5V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Panel Mount | - |
|
ICD-A-500-CAN2-12CURRENT SENSOR - ISA-SCALE DC CO |
65 |
|
|
ICD | Module | Tray | Active | DC | Shunt | 500A | 1 | - | - | - | ±0.1% | ±0.8% | 5.5V ~ 26V | - | 50mA | -40°C ~ 105°C | Automotive | - | Bidirectional | Chassis Mount | - |
|
KIT-ICD-A-300-CAN2-12CURRENT SENSOR WITH CONNECTOR |
32 |
|
|
ICD | Module | Tray | Active | DC | Shunt | 300A | 1 | - | - | - | ±0.1% | ±0.8% | 5.5V ~ 26V | - | 50mA | -40°C ~ 105°C | Automotive | - | Bidirectional | Chassis Mount | - |
|
IVT-3-1K-U0-I-CAN1-12CURRENT SENSOR - ISA-SCALE IVT 3 |
42 |
|
|
- | Module | Tray | Active | DC | Shunt | 1000A | 1 | - | - | - | - | ±0.4% | 12V | - | - | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-300-U0-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
33 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 300A | - | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.