Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LA37S050S05KMCURRENT SENSOR (50A; 5V) -40 105 |
145 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 50A | 1 | Analog Voltage | 12.5mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S100S05KMCURRENT SENSOR (100A; 5V) -40 10 |
142 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 100A | 1 | Analog Voltage | 6.25mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
|
CSDA1BASENSOR CURRENT SWITCH 1A AC/DC |
310 |
|
|
CSDA | Module, Single Pass Through | Bulk | Active | AC/DC | Current Switch | 1A | 1 | NPN | - | - | - | ±0.5% | 6V ~ 16V | 100µs | 12mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HY 10-PSENSOR CURRENT HALL 10A AC/DC |
363 |
|
|
HY | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 10mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
HY 15-PSENSOR CURRENT HALL 15A AC/DC |
145 |
|
|
HY | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 10mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HO 250-SSENSOR CURRENT HALL 250A AC/DC |
106 |
|
|
HO-S | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 250A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HAIS 150-PSENSOR CURRENT HALL 150A AC/DC |
115 |
|
|
HAIS | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAIS 400-PSENSOR CURRENT HALL 400A AC/DC |
101 |
|
|
HAIS | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
HTB 200-PSENSOR CURRENT HALL 200A AC/DC |
398 |
|
|
HTB | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 15mA | -40°C ~ 80°C | - | - | Bidirectional | - | - |
|
L34S500D15TCURRENT SENSOR (500A; 15V) |
115 |
|
|
L34S D15T | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.5% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HSNDR 900-R00TRANSDUCER |
145 |
|
|
HSNDR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 900A | 1 | Ratiometric, Voltage | 2.22mV/A | DC ~ 50kHz | ±0.5% | ±3% | 4.75V ~ 5.25V | 6µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
T60404N4641X903DIFFERENTIAL CURRENT SENSOR FOR |
494 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate | 100A, 150A, 200A (Selectable) | 1 | Open Collector | - | DC ~ 2kHz | - | - | 4.9V ~ 5.1V | - | 45mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
FG-R01-4AFLUX GATE TYPE RESIDUAL CURRENT |
510 |
|
|
FG | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Open Loop | 50mA | 1 | Ratiometric, Voltage | 40V/A | 55Hz | - | - | 4.75V ~ 5.25V | 250ms (AC), 1s (DC) | 13mA (Typ) | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
CSNE151-100SENSOR CURRENT HALL 36A AC/DC |
267 |
|
|
CSN | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 36A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
FG-R02-4AFLUX GATE TYPE RESIDUAL CURRENT |
238 |
|
|
FG | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Open Loop | 50mA | 1 | Ratiometric, Voltage | 40V/A | 55Hz | - | - | 4.75V ~ 5.25V | 250ms (AC), 1s (DC) | 13mA (Typ) | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
RCM14-01RESIDUAL CURRENT MONITOR, 6MA DC |
128 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | DC ~ 60Hz | - | - | 10.8V ~ 13.2V | - | 40mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
CSNV500M-154CSNV500 SERIES HALL-BASED CLOSED |
73 |
|
|
CSNV500 | Module | Box | Active | AC/DC | Hall Effect, Closed Loop | 25A | 3 | CAN Bus | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 200ns | 12mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
RCM14-04RESIDUAL CURRENT MONITOR, 56MA D |
101 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 56mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
HAH3DR 600-S0ETRANSDUCER |
40 |
|
|
HAH3DR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | 3.33mV/A | 40kHz | ±3% | ±3.5% | 4.75V ~ 5.25V | 6µs | 60mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HAL 300-SSENSOR CURRENT HALL 300A AC/DC |
34 |
|
|
HAL | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 300A | 1 | Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | ±15V | 3µs | 25mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.