Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
T60404N4648X300CURRENT SENSOR, 25A, 5 PRI PINS, |
2,150 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 25A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 1µs | 22mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HO 6-P/SP33SENSOR CURRENT HALL 6A AC/DC |
279 |
|
|
HO-P/SP33 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1.4% | 3.3V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 25-P/SP33SENSOR CURRENT HALL 25A AC/DC |
297 |
|
|
HO-P/SP33 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1.4% | 3.3V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 25-PSENSOR CURRENT HALL 25A AC/DC |
271 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1.4% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 10-PSENSOR CURRENT HALL 10A AC/DC |
167 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1.4% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L01Z600S05SENSOR CURRENT HALL 600A AC/DC |
2,216 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 10µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P025S05LSENSOR |
400 |
|
|
F02P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±1% | 5V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P025S05LSENSOR |
1,248 |
|
|
F03P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±0.1% | - | 4.75V ~ 5.25V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P050S05LSENSOR |
547 |
|
|
F03P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±0.1% | - | 4.75V ~ 5.25V | 0.3µs | 55mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L01Z100S05SENSOR CURRENT HALL 100A AC/DC |
172 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 10µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4646X100CURRENT SENSOR, 100A, PRI OPEN, |
2,324 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 1µs | 18mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
L37S300D15MSENSOR |
157 |
|
|
L37S D155 | Module | Tray | Active | DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
LXSR 15-NPSSENSOR CURRENT HALL 15A UNIPOLAR |
321 |
|
|
LXSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LXS 15-NPSSENSOR CURRENT HALL 15A UNIPOLAR |
298 |
|
|
LXS | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±2.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LXSR 25-NPSSENSOR CURRENT HALL 25A UNIPOLAR |
259 |
|
|
LXSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 32.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LES 15-NPSENSOR CURRENT HALL 15A UNIPOLAR |
226 |
|
|
LES | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±2.25% | 4.75V ~ 5.25V | 400ns | 20.8mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LESR 6-NPSENSOR CURRENT HALL 6A UNIPOLAR |
202 |
|
|
LESR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
HX 20-PSENSOR CURRENT HALL 20A AC/DC |
483 |
|
|
HX | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
HX 05-PSENSOR CURRENT HALL 5A AC/DC |
297 |
|
|
HX | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HOB 130-P1 MHZ OPEN-LOOP CURRENT SENSOR 1 |
282 |
|
|
HOB-P | Module | Bulk | Active | AC/DC | Open Loop | 130A | 1 | Voltage | 8mV/A | 1MHz | ±0.45% | - | 4.6V ~ 5.5V | 200ns | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.