| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
HOYL 600-S-0100600A 5V OL BUS BAR MOUNT |
43 |
|
|
HOYL-S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | 1.333mV/A | DC ~ 140kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HOYL 200-S-0100200A 5V OL BUS BAR MOUNT |
32 |
|
|
HOYL-S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 4mV/A | DC ~ 140kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 55-TP/SP27SENSOR CURRENT HALL 50A AC/DC |
33 |
|
|
LA | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.65% | ±12V ~ 15V | 1µs | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LF 305-SSENSOR CURRENT HALL 300A AC/DC |
61 |
|
|
LF | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | 12V ~ 20V | 1µs | 176mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
LA 125-P/SP4SENSOR CURRENT HALL 125A AC/DC |
43 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 0.5µs | 10mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
SSA2-250ASMART CURRENT SENSE SHUNT 250 AM |
161 |
|
|
SSA2 | Module | Bulk | Active | AC/DC | Shunt | 250A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.2% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
|
LF 310-SC/L, ASIC 300A PANEL MOUNT |
118 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | 0.5mA/A | 100kHz | ±0.05% | ±0.2% | 11.4V ~ 21V | 0.5µs | 38mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
SSA2-500ASMART CURRENT SENSE SHUNT 500 AM |
197 |
|
|
SSA2 | Module | Bulk | Active | AC/DC | Shunt | 500A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.2% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
SSA2-1000ASMART CURRENT SENSE SHUNT 1000 A |
164 |
|
|
SSA2 | Module | Bulk | Active | AC/DC | Shunt | 1000A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.2% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 205-SSENSOR CURRENT HALL 200A AC/DC |
119 |
|
|
LA | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | 20mA | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 1500-SSENSOR CURRENT HALL 1500A AC/DC |
38 |
|
|
HAX | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AT 100 B420LSENSOR CURRENT XFMR 100A AC |
193 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | 50/60Hz | ±0.5% | ±1.5% | 20V ~ 30V | 100ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
APR 50 B10SENSOR CURRENT 10A, 25A, 50A |
53 |
|
|
APR | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A, 25A, 50A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 305-SSENSOR CURRENT HALL 300A AC/DC |
47 |
|
|
LA | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | 140mA | 0°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
APR 400 B420LSENSOR CURRENT 200A, 300A, 400A |
53 |
|
|
APR | Module | Bulk | Active | AC | Transformer w/Conditioning | 200A, 300A, 400A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 12V ~ 24V | 400ms | 25mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-SC/L, ASIC 1000A PANEL MOUNT |
32 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | 0.2mA/A | 200kHz | ±0.15% | ±0.2% | 14.25V ~ 25.2V | 0.5µs | 49mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
CR5211-10SENSOR CURRENT MAGNETIC 10A DC |
51 |
|
|
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 10A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
LF 505-SSENSOR CURRENT HALL 500A AC/DC |
112 |
|
|
LF | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | 124mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CR5220-10SENSOR CURRENT MAGNETIC 10A DC |
35 |
|
|
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 10A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 100mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
SSD-100A-C100A - 24BIT ISOLATED SHUNT CUR |
30 |
|
|
SSD | Module | Bulk | Active | DC | Current Sensor | 100A | 1 | CAN Bus | - | - | ±0.1% | ±0.1% | 5V ~ 60V | - | 55mA (Typ) | -40°C ~ 115°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.