| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
ACS758LCB-100B-PFF-TSENSOR CURRENT HALL 100A 5-CB |
1,680 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1.25% | ±2.4% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS758ECB-200U-PFF-TSENSOR CURRENT HALL 200A 5-CB |
1,668 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±1.2% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 85°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS758LCB-100U-PFF-TSENSOR CURRENT HALL 100A 5-CB |
1,265 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1.25% | ±2.4% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS758LCB-050U-PFF-TSENSOR CURRENT HALL 50A 5-CB |
1,162 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 60mV/A | DC ~ 120kHz | ±1% | ±2% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS756KCB-050B-PFF-TSENSOR CURRENT HALL |
189 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1.8% | ±7.5% | 3V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-100U-PFF-TSENSOR CURRENT HALL 100A DC |
11,890 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-050B-PFF-TSENSOR CURRENT HALL 50A AC/DC |
11,486 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS759ECB-200B-PFF-TSENSOR CURRENT HALL 200A AC/DC |
5,393 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 6.6mV/A | DC ~ 120kHz | ±1% | ±4% | 3V ~ 3.6V | 4µs | 13.5mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770KCB-150B-PFF-TSENSOR CURRENT HALL 150A AC/DC |
4,043 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | 13.3mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770ECB-200B-PFF-TSENSOR CURRENT HALL 200A AC/DC |
3,135 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 10mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-100B-PFF-TSENSOR CURRENT HALL 100A AC/DC |
2,336 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770KCB-150U-PFF-TSENSOR CURRENT HALL 150A DC |
2,022 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | 26.7mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS770ECB-200U-PFF-TSENSOR CURRENT HALL 200A DC |
1,657 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS759LCB-050B-PFF-TSENSOR CURRENT HALL 50A AC/DC |
748 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 26.4mV/A | DC ~ 120kHz | ±1% | ±3.5% | 3V ~ 3.6V | 4µs | 13.5mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-050U-PFF-TSENSOR CURRENT HALL 50A DC |
690 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 80mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
T60404N4646X651CURRENT SENSOR, 25A, 3 PRI PINS, |
1,765 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
HXS 20-NPSENSOR CURRENT HALL 5A, 10A, 20A |
1,578 |
|
|
HXS | Module | Tube | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A, 10A, 20A (Selectable) | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
HXS 50-NPSENSOR CURRENT 12.5A, 25A, 50A |
399 |
|
|
HXS | Module | Tube | Not For New Designs | AC/DC | Hall Effect, Open Loop | 12.5A, 25A, 50A (Selectable) | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 6-PSENSOR CURRENT HALL 6A AC/DC |
283 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1.4% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4646X412CURRENT SENSOR, 100A, 3 PRI PINS |
1,357 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 50A, 100A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 500ns | 18.5mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.