Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR4110-20SENSOR CURRENT XFMR 20A AC |
28 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
|
DHR 100 C10SENSOR CURRENT HALL 100A AC/DC |
87 |
|
|
DHR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Panel Mount | - |
|
|
DHR 200 C420SENSOR CURRENT HALL 200A AC/DC |
64 |
|
|
DHR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Panel Mount | - |
|
|
LF 2010-SC/L, ASIC 2000A PANEL MOUNT |
90 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Ratiometric, Current | 0.2mA/A | 150kHz | ±0.1% | ±0.2% | 14.25V ~ 25.2V | 0.5µs | 48mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
IVT-3-1K-U0-I-CAN2-12CURRENT SENSOR - ISA-SCALE IVT 3 |
34 |
|
|
- | Module | Tray | Active | DC | Shunt | 1000A | 1 | - | - | - | - | ±0.4% | 12V | - | - | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-1K-U0-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
61 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 1000A | - | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
KIT - IVT-S-2K5-U3-I-CAN1-12/24 W/ CONNECTORKIT - IVT-S-2K5-U3-I-CAN1-12/24 |
35 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 2500A | 3 | CAN Bus | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-100-U3-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
74 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 100A | 3 | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-300-U3-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
132 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 300A | 3 | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-1K-U3-I-CAN1-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
54 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 1000A | 3 | CAN Bus | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-500-U3-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
210 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 500A | 3 | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-1K-U3-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
152 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 1000A | 3 | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
KIT - IVT-S-100-U3-I-CAN1-12/24 W/ CONNECTORKIT - IVT-S-100-U3-I-CAN1-12/24 |
45 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 100A | 3 | CAN Bus | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
KIT - IVT-S-300-U3-I-CAN2-12/24 W/ CONNECTORKIT - IVT-S-300-U3-I-CAN2-12/24 |
48 |
|
|
- | - | Tray | Active | - | Shunt | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4150-10SENSOR CURRENT XFMR 10A AC |
29 |
|
|
CR4100 | Module, Dual Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 10A | 2 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 75mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
IVT-S-2K5-U3-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
101 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 2500A | 3 | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
KIT - IVT-S-1K-U3-I-CAN2-12/24 W/ CONNECTORKIT - IVT-S-1K-U3-I-CAN2-12/24 W |
56 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 1000A | 3 | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
ISOBLOCK I-ST-1C (10A 10V)TRANSDUCER CURRENT 9-28VDC |
26 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 10A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 2.8µs | - | -25°C ~ 70°C | - | - | - | DIN Rail | - |
|
ACS71240KEXBLT-010B3-115SENSOR CURRENT HALL 10A 12PWRQFN |
2,600 |
|
|
- | 12-PowerWFQFN | Tape & Reel (TR) | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Voltage | 132mV/A | 120kHz | ±1% | ±6% | 3V ~ 3.6V | 4µs | 12mA | -40°C ~ 125°C | Automotive | AEC-Q100 | Bidirectional | Surface Mount | - |
|
CT220BMV-IS5XTREMESENSE HIGH LINEARITY, HIGH |
2,832 |
|
|
XtremeSense™ Crocus | SC-74A, SOT-753 | Tape & Reel (TR) | Active | AC/DC | Magnetoresistive | - | 1 | Ratiometric, Voltage and Current | 1500mV/mT | DC ~ 200kHz | ±0.15% | ±0.5% | 2.7V ~ 5.5V | 20µs | 2.5mA | -40°C ~ 85°C | - | - | Bidirectional | Surface Mount | SOT-23-5 |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.