Einzeldioden
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Technologie | Spannung - Gleichstromsperrspannung (Vr) (Max) | Strom - Durchschnittlich gleichgerichtet (Io) | Spannung - Vorwärtsspannung (Vf) (Max) @ If | Geschwindigkeit | Sperrerholungszeit (trr) | Strom - Sperrleck @ Vr | Kapazität @ Vr, F | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket | Betriebstemperatur - Sperrschicht |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
UT262DIODE GEN PURP 200V 2A A AXIAL |
3,590 |
|
|
- | A, Axial | Bulk | Active | Standard | 200 V | 2A | 1 V @ 900 mA | Standard Recovery >500ns, > 200mA (Io) | - | 2 µA @ 200 V | - | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR11DIODE GEN PURP 100V 1A A AXIAL |
7,579 |
|
|
- | A, Axial | Bulk | Active | Standard | 100 V | 1A | 1.1 V @ 500 mA | Fast Recovery =< 500ns, > 200mA (Io) | 250 ns | 3 µA @ 100 V | 100pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR31DIODE GEN PURP 300V 1A A AXIAL |
9,123 |
|
|
- | A, Axial | Bulk | Active | Standard | 300 V | 1A | 1.1 V @ 500 mA | Fast Recovery =< 500ns, > 200mA (Io) | 300 ns | 3 µA @ 300 V | 70pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR22DIODE GEN PURP 200V 2A A AXIAL |
4,878 |
|
|
- | A, Axial | Bulk | Active | Standard | 200 V | 2A | 1.1 V @ 1 A | Fast Recovery =< 500ns, > 200mA (Io) | 250 ns | 3 µA @ 200 V | 80pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR12DIODE GEN PURP 100V 2A A AXIAL |
3,022 |
|
|
- | A, Axial | Bulk | Active | Standard | 100 V | 2A | 1.1 V @ 1 A | Fast Recovery =< 500ns, > 200mA (Io) | 250 ns | 3 µA @ 100 V | 100pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR32DIODE GEN PURP 300V 2A A AXIAL |
6,476 |
|
|
- | A, Axial | Bulk | Active | Standard | 300 V | 2A | 1.1 V @ 1 A | Fast Recovery =< 500ns, > 200mA (Io) | 300 ns | 3 µA @ 300 V | 70pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UT261DIODE GEN PURP 100V 2A A AXIAL |
5,316 |
|
|
- | A, Axial | Bulk | Active | Standard | 100 V | 2A | 1 V @ 400 mA | Standard Recovery >500ns, > 200mA (Io) | - | 2 µA @ 100 V | - | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR51DIODE GEN PURP 500V 1A A AXIAL |
5,151 |
|
|
- | A, Axial | Bulk | Active | Standard | 500 V | 1A | 1.1 V @ 500 mA | Fast Recovery =< 500ns, > 200mA (Io) | 400 ns | 3 µA @ 500 V | 50pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UT4005DIODE GEN PURP 50V 4A B |
7,806 |
|
|
- | Axial | Bulk | Active | Standard | 50 V | 4A | 1 V @ 3 A | Standard Recovery >500ns, > 200mA (Io) | - | 5 µA @ 50 V | - | - | - | Through Hole | B | -195°C ~ 175°C |
|
UT3010DIODE GEN PURP 100V 3A B |
5,580 |
|
|
- | Axial | Bulk | Active | Standard | 100 V | 3A | 1 V @ 2 A | Standard Recovery >500ns, > 200mA (Io) | - | 5 µA @ 100 V | - | - | - | Through Hole | B | -195°C ~ 175°C |
|
UT255DIODE GEN PURP 500V 1A A AXIAL |
2,480 |
|
|
- | A, Axial | Bulk | Active | Standard | 500 V | 1A | 1 V @ 750 mA | Standard Recovery >500ns, > 200mA (Io) | - | 2 µA @ 500 V | - | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR10DIODE GP 100V 500MA A AXIAL |
9,661 |
|
|
- | A, Axial | Bulk | Active | Standard | 100 V | 500mA | 1.1 V @ 200 mA | Fast Recovery =< 500ns, > 200mA (Io) | 250 ns | 3 µA @ 100 V | 100pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR61DIODE GEN PURP 600V 1A A AXIAL |
6,866 |
|
|
- | A, Axial | Bulk | Active | Standard | 600 V | 1A | 1.1 V @ 500 mA | Fast Recovery =< 500ns, > 200mA (Io) | 400 ns | 3 µA @ 600 V | 40pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR419DIODE GEN PURP 400V 9A A AXIAL |
3,347 |
|
|
- | A, Axial | Bulk | Active | Standard | 400 V | 9A | - | Fast Recovery =< 500ns, > 200mA (Io) | - | - | - | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR42DIODE GEN PURP 400V 2A A AXIAL |
2,136 |
|
|
- | A, Axial | Bulk | Active | Standard | 400 V | 2A | 1.1 V @ 1 A | Fast Recovery =< 500ns, > 200mA (Io) | 350 ns | 3 µA @ 400 V | 60pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR41DIODE GEN PURP 400V 1A A AXIAL |
6,640 |
|
|
- | A, Axial | Bulk | Active | Standard | 400 V | 1A | 1.1 V @ 500 mA | Fast Recovery =< 500ns, > 200mA (Io) | 350 ns | 3 µA @ 400 V | 60pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR21DIODE GEN PURP 200V 1A A AXIAL |
8,793 |
|
|
- | A, Axial | Bulk | Active | Standard | 200 V | 1A | 1.1 V @ 500 mA | Fast Recovery =< 500ns, > 200mA (Io) | 250 ns | 3 µA @ 200 V | 80pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR40DIODE GP 400V 500MA A AXIAL |
6,047 |
|
|
- | A, Axial | Bulk | Active | Standard | 400 V | 500mA | 1.1 V @ 200 mA | Fast Recovery =< 500ns, > 200mA (Io) | 350 ns | 3 µA @ 400 V | 60pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UT267DIODE GEN PURP 600V 2A A AXIAL |
9,855 |
|
|
- | A, Axial | Bulk | Active | Standard | 600 V | 2A | 1 V @ 900 mA | Standard Recovery >500ns, > 200mA (Io) | - | 2 µA @ 600 V | - | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
|
UTR50DIODE GP 500V 500MA A AXIAL |
5,137 |
|
|
- | A, Axial | Bulk | Active | Standard | 500 V | 500mA | 1.1 V @ 200 mA | Fast Recovery =< 500ns, > 200mA (Io) | 400 ns | 3 µA @ 500 V | 50pF @ 0V, 1MHz | - | - | Through Hole | A, Axial | -65°C ~ 175°C |
Kategorieübersicht
Einzeldioden Produkte und Auswahlhilfe
Einzeldioden werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Einzeldioden nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Einzeldioden aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.
