Einzel-IGBTs
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | IGBT-Typ | Spannung - Kollektor-Emitter-Durchbruch (Max) | Strom - Kollektor (Ic) (Max) | Strom - Kollektor gepulst (Icm) | Vce(ein) (Max) @ Vge, Ic | Leistung – Max | Schaltenergie | Eingabetyp | Gate-Ladung | Td (ein/aus) @ 25°C | Testbedingung | Sperrerholungszeit (trr) | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
IRG7PH35UD-EPIGBT |
4,605 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FGPF120N30TUN-CHANNEL IGBT |
3,985 |
|
|
- | TO-220-3 Full Pack | Tube | Obsolete | - | 300 V | 120 A | 180 A | 1.4V @ 15V, 25A | 60 W | - | Standard | 112 nC | - | - | - | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-220F-3 |
|
IRG7PH35UD-EPIGBT 1200V 50A COPAK247 |
3,068 |
|
|
- | TO-247-3 | Bulk | Obsolete | Trench | 1200 V | 50 A | 60 A | 2.2V @ 15V, 20A | 180 W | 1.06mJ (on), 620µJ (off) | Standard | 85 nC | 30ns/160ns | 600V, 20A, 10Ohm, 15V | 105 ns | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-247AD |
|
STGFW40V60FIGBT 600V 80A 62.5W TO-3PF |
196 |
|
|
- | TO-3P-3 Full Pack | Tube | Obsolete | Trench Field Stop | 600 V | 80 A | 160 A | 2.3V @ 15V, 40A | 62.5 W | 456µJ (on), 411µJ (off) | Standard | 226 nC | 52ns/208ns | 400V, 40A, 10Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-3PF |
|
IRG7PH44K10D-EPBFIGBT W/ULTRAFAST SOFT RECOVERY D |
4,250 |
|
|
- | TO-247-3 | Bulk | Active | - | 1200 V | 70 A | 100 A | 2.4V @ 15V, 25A | 320 W | 2.1mJ (on), 1.3mJ (off) | Standard | 200 nC | 75ns/315ns | 600V, 25A, 10Ohm, 15V | 130 ns | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-247AD |
|
AIKB15N65DF5ATMA1DISCRETE SWITCHES |
2,000 |
|
|
- | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Not For New Designs | NPT | 650 V | 15 A | - | - | - | - | Standard | - | - | - | - | - | - | - | Surface Mount | PG-TO263-3-2 |
|
IRGP4263DPBFIGBT W/ULTRAFAST SOFT RECOVERY D |
250 |
|
|
- | TO-247-3 | Bulk | Active | - | 650 V | 90 A | 192 A | 2.1V @ 15V, 48A | 325 W | 2.9mJ (on), 1.4mJ (off) | Standard | 145 nC | 70ns/140ns | 400V, 48A, 10Ohm, 15V | 170 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247AC |
|
HGTG12N60C3DUFS SERIES N-CH IGBT |
236 |
|
|
- | TO-247-3 | Tube | Obsolete | - | 600 V | 24 A | 96 A | 2.2V @ 15V, 15A | 104 W | 380µJ (on), 900µJ (off) | Standard | 48 nC | - | - | 42 ns | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-247 |
|
FGH75T65SHDTLN4FS3 T TO247 75A 650V 4WL |
4,970 |
|
|
- | TO-247-4 | Bulk | Obsolete | Trench Field Stop | 650 V | 150 A | 300 A | 2.1V @ 15V, 75A | 455 W | 1.06mJ (on), 1.56mJ (off) | Standard | 126 nC | 55ns/189ns | 400V, 75A, 15Ohm, 15V | 36 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-4 |
|
HGT4E30N60B3SIGBT 60A, 600V, N CHANNEL, TO 26 |
450 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
IRGP4650D-EPBFIGBT 600V 76A 268W TO247AD |
5,643 |
|
|
- | TO-247-3 | Bulk | Obsolete | - | 600 V | 76 A | 105 A | 1.9V @ 15V, 35A | 268 W | 390µJ (on), 632µJ (off) | Standard | 104 nC | 46ns/105ns | 400V, 35A, 10Ohm, 15V | 120 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247AD |
|
IRGP4263D-EPBFIGBT W/ULTRAFAST SOFT RECOVERY D |
2,905 |
|
|
- | TO-247-3 | Bulk | Active | - | 650 V | 90 A | 192 A | 2.1V @ 15V, 48A | 325 W | 2.9mJ (on), 1.4mJ (off) | Standard | 145 nC | 70ns/140ns | 400V, 48A, 10Ohm, 15V | 170 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247AD |
|
CT30VM-8#G01N CHANNEL IGBT, 400V, FOR STROBE |
1,148 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
MGY40N60DTRANS IGBT CHIP N-CH 600V 66A 3P |
1,588 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
RGTH50TS65DGC11IGBT TRNCH FIELD 650V 50A TO247N |
178 |
|
|
- | TO-247-3 | Tube | Not For New Designs | Trench Field Stop | 650 V | 50 A | 100 A | 2.1V @ 15V, 25A | 174 W | - | Standard | 49 nC | 27ns/94ns | 400V, 25A, 10Ohm, 15V | 58 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RJH3047DPK-80#T2IGBT |
4,981 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HGTG10N120BNDIGBT NPT 1200V 35A TO247-3 |
11,031 |
|
|
- | TO-247-3 | Tube | Obsolete | NPT | 1200 V | 35 A | 80 A | 2.7V @ 15V, 10A | 298 W | 850µJ (on), 800µJ (off) | Standard | 100 nC | 23ns/165ns | 960V, 10A, 10Ohm, 15V | 70 ns | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-247-3 |
|
IRG8P40N120KDPBFIGBT 1200V 60A TO247AC |
7,936 |
|
|
- | TO-247-3 | Bulk | Obsolete | - | 1200 V | 60 A | 75 A | 2V @ 15V, 25A | 305 W | 1.6mJ (on), 1.8mJ (off) | Standard | 240 nC | 40ns/245ns | 600V, 25A, 10Ohm, 15V | 80 ns | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-247AC |
|
HGT4E30N60C3SIGBT 60A, 600V, N CHANNEL, TO 26 |
750 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SGF80N60UFTUIGBT, 80A, 600V, N-CHANNEL |
21,273 |
|
|
- | TO-3P-3 Full Pack | Bulk | Active | - | 600 V | 80 A | 220 A | 2.6V @ 15V, 40A | 110 W | 570µJ (on), 590µJ (off) | Standard | 175 nC | 23ns/90ns | 300V, 40A, 5Ohm, 15V | - | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-3PF |
Kategorieübersicht
Einzel-IGBTs Produkte und Auswahlhilfe
Einzel-IGBTs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Einzel-IGBTs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Einzel-IGBTs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.