IGBT Module
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | IGBT-Typ | Konfiguration | Spannung - Kollektor-Emitter-Durchbruch (Max) | Strom - Kollektor (Ic) (Max) | Leistung – Max | Vce(ein) (Max) @ Vge, Ic | Strom - Kollektor-Abschaltung (Max) | Eingangskapazität (Cies) @ Vce | Eingang | NTC-Thermistor | Betriebstemperatur | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
APTGT600U120D4GIGBT MODULE 1200V 900A 2500W D4 |
5,551 |
|
|
- | D4 | Bulk | Active | Trench Field Stop | Single | 1200 V | 900 A | 2500 W | 2.1V @ 15V, 600A | 5 mA | 40 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | D4 |
|
CM100TF-28HIGBT MOD 1400V 100A 780W |
9,121 |
|
|
IGBTMOD™ | Module | Bulk | Obsolete | - | Three Phase Inverter | 1400 V | 100 A | 780 W | 4.2V @ 15V, 100A | 1 mA | 20 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
CM100TF-24HIGBT MOD 1200V 100A 780W |
2,955 |
|
|
IGBTMOD™ | Module | Bulk | Discontinued at Digi-Key | - | Three Phase Inverter | 1200 V | 100 A | 780 W | 3.4V @ 15V, 100A | 1 mA | 20 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
|
APTGT300TL60GIGBT MODULE 600V 400A 935W SP6 |
9,411 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Three Level Inverter | 600 V | 400 A | 935 W | 1.9V @ 15V, 300A | 350 µA | 18.4 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | SP6 |
|
FS660R08A6P2FLBBPSA1HYBRID PACK DRIVE |
4,190 |
|
|
HybridPACK™ | Module | Tray | Active | Trench Field Stop | Three Phase Inverter | 750 V | 450 A | 1053 W | 1.35V @ 15V, 450A | 1 mA | 80 nF @ 50 V | Standard | Yes | -40°C ~ 150°C (TJ) | Chassis Mount | AG-HYBRIDD-1 |
|
QID1210005IGBT MODULE 1200V 100A 730W |
6,719 |
|
|
- | - | Bulk | Discontinued at Digi-Key | - | 2 Independent | 1200 V | 100 A | 730 W | 6.5V @ 15V, 100A | 1 mA | 16 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | - | - |
|
APTGT150H120GIGBT MODULE 1200V 220A 690W SP6 |
3,023 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Full Bridge Inverter | 1200 V | 220 A | 690 W | 2.1V @ 15V, 150A | 350 µA | 10.7 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | SP6 |
|
CM400DU-24FIGBT MOD 1200V 400A 1100W |
8,958 |
|
|
IGBTMOD™ | Module | Bulk | Discontinued at Digi-Key | - | Half Bridge | 1200 V | 400 A | 1100 W | 2.4V @ 15V, 400A | 2 mA | 160 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
|
BSM50GP120BOSA1IGBT MODULE 1200V 50A |
9,725 |
|
|
- | Module | Tray | Obsolete | - | 3 Phase Inverter | 1200 V | 80 A | - | 2.55V @ 15V, 50A | 500 µA | 3.3 pF @ 25 V | Three Phase Bridge Rectifier | Yes | -40°C ~ 125°C | Chassis Mount | Module |
|
APTGL700DA120D3GIGBT MODULE 1200V 840A 3000W D3 |
3,748 |
|
|
- | Module | Bulk | Active | Trench Field Stop | Single | 1200 V | 840 A | 3000 W | 2.2V @ 15V, 600A | 5 mA | 37.2 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | D3 |
|
APTGL700SK120D3GIGBT MODULE 1200V 840A 3000W D3 |
3,566 |
|
|
- | Module | Bulk | Active | Trench Field Stop | Single | 1200 V | 840 A | 3000 W | 2.2V @ 15V, 600A | 5 mA | 37.2 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | D3 |
|
FF450R12IE4BOSA2IGBT MOD 1200V 450A 2550W |
4,587 |
|
|
PrimePACK™2 | Module | Tray | Active | Trench Field Stop | 2 Independent | 1200 V | 450 A | 2550 W | 2.05V @ 15V, 450A | 5 mA | 27 nF @ 25 V | Standard | Yes | -40°C ~ 150°C | Chassis Mount | Module |
|
APTGT300A120D3GIGBT MODULE 1200V 440A 1250W D3 |
2,236 |
|
|
- | D-3 Module | Bulk | Active | Trench Field Stop | Half Bridge | 1200 V | 440 A | 1250 W | 2.1V @ 15V, 300A | 8 mA | 20 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | D3 |
|
APTGT400U170D4GIGBT MODULE 1700V 800A 2080W D4 |
3,420 |
|
|
- | D4 | Bulk | Active | Trench Field Stop | Single | 1700 V | 800 A | 2080 W | 2.4V @ 15V, 400A | 1 mA | 33 nF @ 25 V | Standard | No | - | Chassis Mount | D4 |
|
APTGL325A120D3GIGBT MODULE 1200V 420A 1500W D3 |
8,395 |
|
|
- | D-3 Module | Bulk | Active | Trench Field Stop | Half Bridge | 1200 V | 420 A | 1500 W | 2.2V @ 15V, 300A | 5 mA | 18.6 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | D3 |
|
CM600DU-24NFHIGBT MOD 1200V 600A 1550W |
5,713 |
|
|
IGBTMOD™ | Module | Bulk | Discontinued at Digi-Key | - | Half Bridge | 1200 V | 600 A | 1550 W | 6.5V @ 15V, 600A | 1 mA | 95 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
FS75R12KS4BOSA1IGBT MOD 1200V 100A 500W |
9,381 |
|
|
- | Module | Tray | Obsolete | - | Three Phase Inverter | 1200 V | 100 A | 500 W | 3.7V @ 15V, 75A | 5 mA | 5.1 nF @ 25 V | Standard | No | -40°C ~ 125°C | Chassis Mount | Module |
|
FS400R07A1E3BOSA1IGBT MOD 650V 500A 1250W |
3,765 |
|
|
- | Module | Tray | Obsolete | - | Three Phase Inverter | 650 V | 500 A | 1250 W | 1.9V @ 15V, 400A | 1 mA | 26 nF @ 25 V | Standard | Yes | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
NVH820S75L4SPCAUTOMOTIVE 750V, 820A SSDC POWER |
4,685 |
|
|
- | Module | Bulk | Active | - | Three Phase Inverter | 750 V | 820 A | 1000 W | 1.55V @ 15V, 600A | 500 µA | - | Standard | Yes | -40°C ~ 175°C (TJ) | Chassis Mount | SSDC33 |
|
NVH820S75L4SPMAUTOMOTIVE 750V, 820A SSDC POWER |
2,131 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
IGBT Module Produkte und Auswahlhilfe
IGBT Module werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie IGBT Module nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden IGBT Module aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.