IGBT Module
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | IGBT-Typ | Konfiguration | Spannung - Kollektor-Emitter-Durchbruch (Max) | Strom - Kollektor (Ic) (Max) | Leistung – Max | Vce(ein) (Max) @ Vge, Ic | Strom - Kollektor-Abschaltung (Max) | Eingangskapazität (Cies) @ Vce | Eingang | NTC-Thermistor | Betriebstemperatur | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
APTGT225SK170GIGBT MODULE 1700V 340A 1250W SP6 |
9,017 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Single | 1700 V | 340 A | 1250 W | 2.4V @ 15V, 225A | 500 µA | 20 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | SP6 |
|
CM100TU-24FIGBT MOD 1200V 100A 500W |
8,922 |
|
|
IGBTMOD™ | Module | Bulk | Discontinued at Digi-Key | Trench | Three Phase Inverter | 1200 V | 100 A | 500 W | 2.4V @ 15V, 100A | 1 mA | 39 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
CM600HU-24FIGBT MOD 1200V 600A 2400W |
7,560 |
|
|
IGBTMOD™ | Module | Bulk | Discontinued at Digi-Key | Trench | Single | 1200 V | 600 A | 2400 W | 2.4V @ 15V, 600A | 2 mA | 230 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
FF600R12ME4PBOSA1IGBT MODULE VCES 600V 600A |
9,036 |
|
|
EconoDUAL™ 3 | - | Tray | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FF600R12ME4PB11BOSA1IGBT MODULE VCES 600V 600A |
4,500 |
|
|
EconoDUAL™ 3 | - | Tray | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
MG17300WB-BN4MMIGBT MODULE 1700V 375A 1650W WB |
9,392 |
|
|
- | Module | Bulk | Obsolete | Trench Field Stop | Half Bridge | 1700 V | 375 A | 1650 W | 2.45V @ 15V, 300A | 3 mA | 27 nF @ 25 V | Standard | Yes | -40°C ~ 125°C (TJ) | Chassis Mount | WB |
|
|
CM600DY-24SIGBT MOD 1200V 600A 4050W |
7,460 |
|
|
- | Module | Bulk | Discontinued at Digi-Key | - | Half Bridge | 1200 V | 600 A | 4050 W | 2.25V @ 15V, 600A | 1 mA | 60 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
FF600R12ME4CB11BPSA1MEDIUM POWER ECONO AG-ECONOD-411 |
7,124 |
|
|
EconoDUAL™ 3 | Module | Tray | Not For New Designs | Trench Field Stop | 2 Independent | 1200 V | 1060 A | 4050 W | 2.1V @ 15V, 600A | 3 mA | 37 nF @ 25 V | Standard | Yes | -40°C ~ 150°C (TJ) | Chassis Mount | AG-ECONOD |
|
APTGT300DH60GIGBT MODULE 600V 430A 1150W SP6 |
3,242 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Asymmetrical Bridge | 600 V | 430 A | 1150 W | 1.8V @ 15V, 300A | 350 µA | 24 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | SP6 |
|
APTGT400DA120GIGBT MODULE 1200V 560A 1785W SP6 |
8,839 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Single | 1200 V | 560 A | 1785 W | 2.1V @ 15V, 400A | 750 µA | 28 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | SP6 |
|
APTGT400SK120GIGBT MODULE 1200V 560A 1785W SP6 |
8,470 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Single | 1200 V | 560 A | 1785 W | 2.1V @ 15V, 400A | 750 µA | 28 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | SP6 |
|
|
FS200R07A1E3BOSA1IGBT MOD 650V 250A 790W |
5,833 |
|
|
- | Module | Tray | Obsolete | - | Three Phase Inverter | 650 V | 250 A | 790 W | 1.9V @ 15V, 200A | 1 mA | 13 nF @ 25 V | Standard | Yes | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
CM400DU-24NFHIGBT MOD 1200V 400A 1040W |
9,754 |
|
|
IGBTMOD™ | Module | Bulk | Discontinued at Digi-Key | - | Half Bridge | 1200 V | 400 A | 1040 W | 6.5V @ 15V, 400A | 1 mA | 63 nF @ 10 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
|
|
APTGL475U120D4GIGBT MODULE 1200V 610A 2082W D4 |
5,273 |
|
|
- | D4 | Bulk | Active | Trench Field Stop | Single | 1200 V | 610 A | 2082 W | 2.2V @ 15V, 400A | 4 mA | 24.6 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | D4 |
|
APTGLQ200HR120GIGBT MODULE 1200V 300A 1000W SP6 |
3,102 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | - | 1200 V | 300 A | 1000 W | 2.4V @ 15V, 160A | 200 µA | 9.2 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Through Hole | SP6 |
|
APTGT150TA60PGIGBT MODULE 600V 225A 480W SP6P |
5,692 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Three Phase | 600 V | 225 A | 480 W | 1.9V @ 15V, 150A | 250 µA | 9.2 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | SP6-P |
|
APTGT150TDU60PGIGBT MODULE 600V 225A 480W SP6P |
9,156 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Triple, Dual - Common Source | 600 V | 225 A | 480 W | 1.9V @ 15V, 150A | 250 µA | 9.2 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | SP6-P |
|
|
APTGT75TA120PGIGBT MODULE 1200V 100A 350W SP6P |
2,704 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Three Phase | 1200 V | 100 A | 350 W | 2.1V @ 15V, 75A | 250 µA | 5.34 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | SP6-P |
|
|
APTGT75TDU120PGIGBT MODULE 1200V 100A 350W SP6P |
8,051 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Triple, Dual - Common Source | 1200 V | 100 A | 350 W | 2.1V @ 15V, 75A | 250 µA | 5.34 nF @ 25 V | Standard | No | - | Chassis Mount | SP6-P |
|
|
APTGL475U120DAGIGBT MODULE 1200V 610A 2307W SP6 |
6,142 |
|
|
- | SP6 | Bulk | Active | Trench Field Stop | Single | 1200 V | 610 A | 2307 W | 2.2V @ 15V, 400A | 4 mA | 24.6 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | SP6 |
Kategorieübersicht
IGBT Module Produkte und Auswahlhilfe
IGBT Module werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie IGBT Module nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden IGBT Module aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.