Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HAH3DR 900-S07SENSOR CURRENT |
0 |
|
|
- | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 510-S/SP2SENSOR CURRENT HALL |
0 |
|
|
- | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DHR 300 C420/SP5SENSOR CURRENT HALL |
0 |
|
|
DHR | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Current Sensor | 300A | 1 | Current | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | - | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LH 100-P/SP10SENSOR CURRENT HALL |
0 |
|
|
- | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LA 205-S/SP11SENSOR CURRENT HALL |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Closed Loop | 200A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.8% | ±24V | 1µs | 35mA | -30°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-S/SP1SENSOR CURRENT HALL |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Closed Loop | 1000A | 1 | Current | - | DC ~ 200kHz | ±0.15% | - | 14.25V ~ 25.2V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
RAZNC-305XUNF3,000A Current Sensor |
0 |
|
|
RAZNC | - | Retail Package | Active | AC/DC | Hall Effect, Open Loop | 3000A | 1 | Analog Voltage | 0.75mV/A | 210kHz | ±0.2% | ±1% | 5V | 1µs | 100mA | -40°C ~ 100°C | - | - | Bidirectional | Free Hanging | - |
|
RAZC-173XTAN17A Current Sensor |
0 |
|
|
RAZC | - | Tray | Active | AC/DC | Hall Effect, Open Loop | 17A | 1 | Analog Voltage | 99mV/A | 100kHz | 1% | - | 5V | 3µs | 15mA | -40°C ~ 120°C | - | - | Bidirectional | Through Hole | - |
|
RAZP-20002000A Current Probe |
0 |
|
|
* | - | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | 1mV/A | 350kHz | ±0.1% | ±1% | 5V | 0.1µs | 25mA | -40°C ~ 100°C | - | - | Bidirectional | Screw | - |
|
A/MCSMini, Fixed Current Switch, Soli |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Switch | 150A | 1 | Relay, NO | - | 50/60Hz | - | - | 600VAC | 50ms | - | -30°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
A/MSCSMini, Fixed Current Switch, Spli |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Switch | 150A | 1 | Relay, NO | - | 50/60Hz | - | - | 600VAC | 40ms | - | -30°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
4LS-400A:333mV-1.5x1.5 (1.0%)1.5" SPLIT-CORE 400A:333mV 1% |
1 |
|
|
4LS | - | Case | Active | AC | Current Sensor | 400A | 1 | Ratiometric, 0V ~ 0.333V | - | - | - | ±1% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
A/CS2Fixed Current Switch, DIN Rail, |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Switch | 250A | 1 | Relay, NO | - | 40Hz ~ 1kHz | - | - | 600VAC | - | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
A/CSX2Fixed Current Switch, DIN Rail, |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Switch | 250A | 1 | Relay, NC | - | 40Hz ~ 1kHz | - | - | 600VAC | - | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
A/MSCS-AMini, Adjustable Current Switch, |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Switch | 150A | 1 | Relay, NO | - | 50/60Hz | - | - | 600VAC | 45ms | - | -30°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
4DS-250A:5VDC-1x11" SPLIT-CORE 250A:5VDC |
1 |
|
|
4DS | - | Case | Active | AC | Current Sensor | 250A | 1 | Ratiometric, 0V ~ 5V | - | - | - | - | - | - | - | -20°C ~ 55°C | - | - | - | Free Hanging | - |
|
LN2-5A:333mV(0.5%)0.5" SPLIT-CORE 5A:333mV 0.5% |
1 |
|
|
LN2 | - | Case | Active | AC | Current Sensor | 5A | 1 | Ratiometric, 0V ~ 0.333V | - | - | - | ±0.5% | - | - | - | -20°C ~ 55°C | - | - | - | Free Hanging | - |
|
A/SCSX2Fixed Current Switch, DIN Rail, |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Switch | 200A | 1 | Relay, NC | - | 40Hz ~ 1kHz | - | - | 600VAC | - | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
A/SCS2Fixed Current Switch, DIN Rail, |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Switch | 200A | 1 | Relay, NO | - | 40Hz ~ 1kHz | - | - | 600VAC | - | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
A/CTE2-150Analog Current Sensor, 0-5 VDC, |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Sensor | 50A, 100A, 150A (Selectable) | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 600Hz | - | ±1% | 600VAC | 300ms | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.