Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HLSR 100-P/SP13SENSOR CURRENT HALL AC/DC |
0 |
|
|
* | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOP 200-SB/SP1SENSOR CURRENT HALL AC/DC |
0 |
|
|
* | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20311009106CURRENT SENSOR |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | - | - | 0Hz ~ 100kHz | ±0.1% | ±0.4% | 15V ~ 24V | 1µs | 228mA | -40°C ~ 85°C | - | - | - | Panel Mount | - |
|
20312000103CURRENT SENSOR |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | - | - | 0Hz ~ 100kHz | ±0.1% | ±0.3% | 15V ~ 24V | 1µs | 520mA | -20°C ~ 85°C | - | - | - | Panel Mount | - |
|
20322000401CURRENT SENSOR |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 2000A | 1 | - | - | 0Hz ~ 50kHz | ±0.7% | ±1% | 14.25V ~ 15.75V | 3µs | 17mA | -40°C ~ 85°C | - | - | - | Panel Mount | - |
|
20311400101CURRENT SENSOR |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 1400A | 1 | - | - | 0Hz ~ 100kHz | ±0.1% | ±0.4% | 15V ~ 24V | 1µs | 492mA | 5°C ~ 60°C | - | - | - | Panel Mount | - |
|
20310200304CURRENT SENSOR |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 200A | 1 | - | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | 12V ~ 15V | 1µs | 117mA | -40°C ~ 85°C | - | - | - | Panel Mount | - |
|
37004CURRENT XDUCER 150A/4-20MA |
0 |
|
|
- | Module, Single Pass Through | Retail Package | Active | AC | Current Transducer | 150A | 1 | Ratiometric, 4mA ~ 20mA | - | 60Hz | - | ±0.04% | 21.6V ~ 26.4V | - | - | -30°C ~ 65°C | - | - | Unidirectional | Chassis Mount | - |
|
37001CURRENT XDUCER 50A/4-20MA |
0 |
|
|
- | Module, Single Pass Through | Retail Package | Active | AC | Current Transducer | 50A | 1 | Ratiometric, 4mA ~ 20mA | - | 60Hz | - | ±0.04% | 21.6V ~ 26.4V | - | - | -30°C ~ 65°C | - | - | Unidirectional | Chassis Mount | - |
|
37002CURRENT XDUCER 75A/4-20MA |
0 |
|
|
- | Module, Single Pass Through | Retail Package | Active | AC | Current Transducer | 75A | 1 | Ratiometric, 4mA ~ 20mA | - | 60Hz | - | ±0.04% | 21.6V ~ 26.4V | - | - | -30°C ~ 65°C | - | - | Unidirectional | Chassis Mount | - |
|
MLX91217LVA-ACS-001-SPSENSOR CURRENT HALL 15MV/MT 4SIP |
0 |
|
|
- | 4-SSIP Module | Tube | Active | DC | Hall Effect | - | 1 | Ratiometric, Voltage | 15mV/mT | DC ~ 250kHz | ±0.2% | - | 4.5V ~ 5.5V | 2µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | - |
|
MLX91217LVA-ACT-004-SPSENSOR CURRENT HALL 15MV/MT 4SIP |
0 |
|
|
- | 4-SSIP Module | Tube | Active | DC | Hall Effect | - | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.2% | - | 4.5V ~ 5.5V | 2µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | - |
|
MLX91217LVA-ACZ-000-SPSENSOR CURRENT HALL 10MV/MT 4SIP |
0 |
|
|
- | 4-SMD, Gull Wing | Tube | Active | DC | Hall Effect | - | 1 | Ratiometric, Voltage | 10mV/mT | DC ~ 250kHz | ±0.2% | - | 4.5V ~ 5.5V | 2µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | - |
|
MLX91217LVA-ACS-000-SPSENSOR CURRENT HALL 10MV/MT 4SIP |
0 |
|
|
- | 4-SSIP Module | Tube | Active | DC | Hall Effect | - | 1 | Ratiometric, Voltage | 10mV/mT | DC ~ 250kHz | ±0.2% | - | 4.5V ~ 5.5V | 2µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | - |
|
A/SCTV2-50Analog Current Sensor, 0-10 VDC, |
0 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Sensor | 10A, 20A, 50A (Selectable) | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 600Hz | - | ±1% | 600VAC | 300ms | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
A/CTA2-50-RMSAnalog Current Sensor, 4-20mA, D |
0 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Sensor | 10A, 20A, 50A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 15Hz ~ 100Hz | - | ±1% | 8.5V ~ 30V | 600ms | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
A/ASCS2Adjustable Current Switch, DIN R |
0 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Switch | 250A | 1 | Relay, NO | - | 40Hz ~ 1kHz | - | - | 600VAC | - | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
A/SCTE2-250Analog Current Sensor, 0-5 VDC, |
0 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Sensor | 100A, 200A, 250A (Selectable) | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 600Hz | - | ±1% | 600VAC | 300ms | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
TMR7303-010D/P1MINI TMR CURRENT SENSOR NOM 10A |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Magnetoresistive, Open Loop | 10A | 1 | Ratiometric, Voltage | 80mV/A | DC ~ 500kHz | ±0.3% | ±4% | 4.75V ~ 5.25V | 0.6µs | 4mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TMR7303-080D/P1MINI TMR CURRENT SENSOR NOM 80A |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Magnetoresistive, Open Loop | 80A | 1 | Ratiometric, Voltage | 10mV/A | DC ~ 600kHz | ±0.5% | ±3% | 4.75V ~ 5.25V | 500ps | 4mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.