Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HC5FW 600-STRANSDUCER |
0 |
|
|
HC5FW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | 3.33mV/A | 40kHz | ±1% | ±3% | 4.75V ~ 5.25V | 6µs | 25mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
LZSR 100-TPCLOSED-LOOP CURRENT SENSOR 100A |
1 |
|
|
LZSR-TP | Module | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Voltage | 6.25mV/A | DC ~ 200kHz | ±0.15% | - | 4.75V ~ 5.25V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
FG-R04-4GASENSOR CURRENT FLUX 40A UL VRT |
0 |
|
|
FG | Module | Box | Active | AC/DC | Flux Gate, Open Loop | 50mA | 1 | Ratiometric, Voltage | 40V/A | DC ~ 55Hz | - | - | 4.75V ~ 5.25V | 250ms (AC), 1s (DC) | 13mA (Typ) | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
FG-R01-4GASENSOR CURRENT FLUX 40A UL HRZ |
0 |
|
|
FG | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Open Loop | 50mA | 1 | Ratiometric, Voltage | 40V/A | DC ~ 55Hz | - | - | 4.75V ~ 5.25V | 250ms (AC), 1s (DC) | 13mA (Typ) | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
RCMP20HT-03RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-03 | Module, Single Pass Through | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20HT-01RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-01 | Module, Single Pass Through | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20VT-03RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-03 | Module, Single Pass Through | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20HC2-03RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-03 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20VC2-01RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-01 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20HC4-03RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-03 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20VT-01RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-01 | Module, Single Pass Through | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20HC2-01RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-01 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20VC2-03RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-03 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20VC3-01RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-01 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20HC3-03RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-03 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20VC4-01RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-01 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20VC3-03RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-03 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20HC3-01RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-01 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20HC4-01RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-01 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
RCMP20VC4-03RCM RESIDUAL CURRENT MONITORS |
0 |
|
|
RCMP20-03 | Module | Tray | Active | AC/DC | Current Sensor | 6mA | 1 | Current | - | 50Hz ~ 60Hz | - | - | 4.75V ~ 5.25V | 10s | 2.5mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.