Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MCQ1823GQTE-505BRNAEC-PAUTOMOTIVE-GRADE, LINEAR HALL-EF |
0 |
|
|
- | 12-PowerWFQFN | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 5A | 1 | Ratiometric, Voltage | 400mV/A | 120kHz | ±0.5% | ±2.5% | 4.5V ~ 5.5V | 4µs | 12mA | -40°C ~ 125°C (TJ) | Automotive | AEC-Q101 | Bidirectional | Surface Mount, Wettable Flank | 12-TQFN (3x3) |
|
MCQ1823GQTE-530BRNAEC-PAUTOMOTIVE-GRADE, LINEAR HALL-EF |
0 |
|
|
- | 12-PowerWFQFN | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 30A | 1 | Ratiometric, Voltage | 66mV/A | 120kHz | ±0.5% | ±2.5% | 4.5V ~ 5.5V | 4µs | 12mA | -40°C ~ 125°C (TJ) | Automotive | AEC-Q101 | Bidirectional | Surface Mount, Wettable Flank | 12-TQFN (3x3) |
|
ACS37030LLZATR-065B3CURRENT SENSOR 5 MHZ |
0 |
|
|
- | 8-SOIC (0.154", 3.90mm Width), 6 Leads | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 65A | 1 | Analog Voltage | 20.3mV/A | DC ~ 5MHz | - | - | 3V ~ 3.6V | 40ns | 30mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | 6-SOIC |
|
MLX91231KDC-BBA-000-SPMLX91231, AN INTELLIGENTSHUNT-BA |
1 |
|
|
- | - | Tray | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ACS37002LMABTR-050B5-M400KHZ CURRENT SENSOR WITH VREF |
0 |
|
|
ACS37002 | 16-SOIC (0.295", 7.50mm Width) | Tape & Reel (TR) | Active | DC | Hall Effect | 50A | 1 | Ratiometric, Voltage | 40mV/A | 400kHz | ±0.75% | ±1.75% | 4.5V ~ 5.5V | 2.5µs | 18mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | 16-SOIC |
|
HO 25-NP-0000SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
HO-NP-0000 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L37S400S05MCURRENT SENSOR (400A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CKSR 75-NPSENSOR CURRENT FLUX 75A AC/DC |
0 |
|
|
CKSR | Module | Tray | Active | AC/DC | Flux Gate, Closed Loop | 75A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±1% | ±0.8% | 4.75 ~ 5.25V | 0.3µs | 20mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 100-PW-0000DIGITAL OUTPUT OL PCB MT 100A |
0 |
|
|
HO-PW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | - | ±0.6% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 50-P/SP11 MHZ OPEN-LOOP CURRENT SENSOR 5 |
0 |
|
|
HOB-P/SP1 | Module | Bulk | Active | AC/DC | Open Loop | 50A | 1 | Voltage | 32mV/A | 1MHz | ±0.7% | - | 4.6V ~ 5.5V | - | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LA37S300S05KMCURRENT SENSOR (300A; 5V) -40 10 |
0 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 300A | 1 | Analog Voltage | 2.083mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
CTS-CS-CAX-04-0254mm Clamp-On Current Sensor 25A |
0 |
|
|
* | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CTS-CS-CAX-04-0504mm Clamp-On Current Sensor 50A |
0 |
|
|
* | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CTS-CS-CAX-04-0754mm Clamp-on Current Sensor 75A |
0 |
|
|
* | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HO 100-SW-0000DIGITAL OUTPUT OL PANEL MT 100A |
0 |
|
|
HO-SW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | - | ±0.6% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HO 60-PSENSOR CURRENT HALL 60A AC/DC |
0 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 60A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.75% | ±1.25% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 80-NPW-0000DIGITAL OUTPUT OL PCB MT 80A |
0 |
|
|
HO-NPW | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 80A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CTS-CS-CAX-10-05010mm Clamp-on Current Sensor 50A |
0 |
|
|
* | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CTS-CS-CAX-10-20010mm Clamp-on Current Sensor 200 |
0 |
|
|
* | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CTS-CS-CAX-10-10010mm Clamp-on Current Sensor 100 |
0 |
|
|
* | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.