TRIACs
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Triac-Typ | Spannung - Aus-Zustand | Strom - Einschaltzustand (It (RMS)) (Max) | Spannung - Gate-Trigger (Vgt) (Max) | Strom - Nicht-Rep.-Spannung 50, 60 Hz (Itsm) | Strom - Gate-Trigger (Igt) (Max) | Strom - Halten (Ih) (max.) | Konfiguration | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
T410-800B-TRTRIAC SENS GATE 800V 4A DPAK |
4,997 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 4 A | 1.3 V | 30A, 31A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | DPAK |
|
L0103NTRPTRIAC SENS GATE 800V 1A SOT223 |
4,454 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 1 A | 1.3 V | 10A, 12A | 3 mA | 7 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
L0109NTRPTRIAC SENS GATE 800V 1A SOT223 |
1,150 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 1 A | 1.3 V | 10A, 12A | 10 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
ACST310-8BTRIAC SENS GATE 800V 3A DPAK |
3,024 |
|
|
ACS™/A.S.D® | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Bulk | Active | Logic - Sensitive Gate | 800 V | 3 A | 1.1 V | 20A, 21A | 10 mA | 20 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | DPAK |
|
T435-600HTRIAC ALTERNISTOR 600V 4A TO251 |
2,744 |
|
|
Snubberless™ | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Alternistor - Snubberless | 600 V | 4 A | 1.3 V | 30A, 31A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-251 (IPAK) |
|
ACST435-8BTRTRIAC 800V 4A DPAK |
4,369 |
|
|
ACS™/A.S.D® | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Standard | 800 V | 4 A | 1.1 V | 30A, 32A | 35 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | DPAK |
|
LX807MBRPTRIAC SENS GATE 600V 0.8A SOT89 |
723 |
|
|
LX8 | TO-243AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 800 mA | 1.3 V | 8A, 9.5A | 5 mA | 5 mA | Single | -40°C ~ 110°C (TJ) | - | - | Surface Mount | SOT-89 |
|
L601E5TRIAC SENS GATE 600V 1A TO92 |
3,957 |
|
|
- | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.3 V | 16.7A, 20A | 5 mA | 10 mA | Single | -65°C ~ 125°C (TJ) | - | - | Through Hole | TO-92 |
|
SST24A-800BWTRIAC 800V 25A TO220AINS |
5,210 |
|
|
SST24 | TO-220-3 | Tube | Active | Standard | 800 V | 25 A | 1.3 V | 250A @ 50Hz | 50 mA | 75 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AIns |
|
|
T835T-8TTRIAC ALTERNISTOR 800V 8A TO220 |
3,820 |
|
|
Snubberless™ | TO-220-3 | Tube | Active | Alternistor - Snubberless | 800 V | 8 A | 1.3 V | 60A, 63A | 35 mA | 40 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220 |
|
|
T810T-8TTRIAC SENS GATE 800V 8A TO220 |
945 |
|
|
- | TO-220-3 | Tube | Active | Logic - Sensitive Gate | 800 V | 8 A | 1.3 V | 60A, 63A | 10 mA | 15 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220 |
|
T1235T-8G-TRTRIAC ALTERNISTOR 800V 12A D2PAK |
3,006 |
|
|
Snubberless™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 800 V | 12 A | 1.3 V | 95A, 90A | 35 mA | 40 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | D2PAK |
|
T1235T-8GTRIAC ALTERNISTOR 800V 12A D2PAK |
1,859 |
|
|
Snubberless™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Alternistor - Snubberless | 800 V | 12 A | 1.3 V | 95A, 90A | 35 mA | 40 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | D2PAK |
|
|
BTB12-600CRGTRIAC 600V 12A TO220 |
991 |
|
|
- | TO-220-3 | Tube | Active | Standard | 600 V | 12 A | 1.3 V | 120A, 126A | 25 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
|
BTB12-600SWRGTRIAC SENS GATE 600V 12A TO220 |
1,984 |
|
|
- | TO-220-3 | Tube | Active | Logic - Sensitive Gate | 600 V | 12 A | 1.3 V | 120A, 126A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
|
BTA06-800TWRGTRIAC SENS GATE 800V 6A TO220 |
1,792 |
|
|
- | TO-220-3 | Tube | Active | Logic - Sensitive Gate | 800 V | 6 A | 1.3 V | 60A, 63A | 5 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
|
T1220T-6ITRIAC ALTERNSTR 600V 12A TO220AB |
998 |
|
|
- | TO-220-3 | Tube | Active | Alternistor - Snubberless | 600 V | 12 A | 1.3 V | 90A, 95A | 20 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB Insulated |
|
|
T405-600TTRIAC SENS GATE 600V 4A TO220 |
1,966 |
|
|
- | TO-220-3 | Tube | Active | Logic - Sensitive Gate | 600 V | 4 A | 1.3 V | 30A, 31A | 5 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
MAC8MGTRIAC 600V 8A TO220AB |
616 |
|
|
- | TO-220-3 | Box | Active | Standard | 600 V | 8 A | 1.5 V | 80A @ 60Hz | 35 mA | 40 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
T810H-6GTRIAC SENS GATE 600V 8A D2PAK |
1,797 |
|
|
- | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Logic - Sensitive Gate | 600 V | 8 A | 1 V | 80A, 84A | 10 mA | 25 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | D2PAK |
Kategorieübersicht
TRIACs Produkte und Auswahlhilfe
TRIACs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie TRIACs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden TRIACs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.
