| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Triac-Typ | Spannung - Aus-Zustand | Strom - Einschaltzustand (It (RMS)) (Max) | Spannung - Gate-Trigger (Vgt) (Max) | Strom - Nicht-Rep.-Spannung 50, 60 Hz (Itsm) | Strom - Gate-Trigger (Igt) (Max) | Strom - Halten (Ih) (max.) | Konfiguration | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L4008L6TPTRIAC SENS GATE 400V 8A TO220AB |
7,887 |
|
|
- | TO-220-3 Isolated Tab | Tube | Active | Logic - Sensitive Gate | 400 V | 8 A | 1.3 V | 65A, 85A | 10 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220AB-L |
|
BTA26-800BWRGTRIAC ALTERNISTOR 800V 25A TOP3 |
779 |
|
|
Snubberless™ | TOP-3 Insulated | Tube | Active | Alternistor - Snubberless | 800 V | 25 A | 1.3 V | 250A, 260A | 50 mA | 75 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TOP3 |
|
BTA41-600BRGTRIAC 600V 40A TOP3 |
2,758 |
|
|
- | TOP-3 Insulated | Tube | Active | Standard | 600 V | 40 A | 1.3 V | 400A, 420A | 50 mA | 80 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TOP3 |
|
BTA41-800BRGTRIAC 800V 40A TOP3 |
1,754 |
|
|
- | TOP-3 Insulated | Tube | Active | Standard | 800 V | 40 A | 1.3 V | 400A, 420A | 50 mA | 80 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TOP3 |
|
T2535-800G-TRTRIAC ALTERNISTOR 800V 25A D2PAK |
20,752 |
|
|
Snubberless™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 800 V | 25 A | 1.3 V | 250A, 260A | 35 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | D2PAK |
|
T2550-12G-TRTRIAC ALTERNSTR 1.2KV 25A D2PAK |
33,150 |
|
|
Snubberless™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 1.2 kV | 25 A | 1.3 V | 240A, 252A | 50 mA | 60 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | D2PAK |
|
Q6025L6TPTRIAC ALTERNISTOR 600V 25A TO220 |
4,784 |
|
|
- | TO-220-3 Isolated Tab | Tube | Active | Alternistor - Snubberless | 600 V | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
Q6015L5TPTRIAC 600V 15A TO220 |
337 |
|
|
- | TO-220-3 Isolated Tab | Tube | Active | Standard | 600 V | 15 A | 2 V | 167A, 200A | 50 mA | 70 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
Q8016LH6TPTRIAC ALTERNSTR 800V 16A TO220AB |
2,660 |
|
|
- | TO-220-3 Isolated Tab | Tube | Active | Alternistor - Snubberless | 800 V | 16 A | 1.3 V | 167A, 200A | 80 mA | 70 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB-L |
|
Q8016NH4RPTRIAC ALTERNISTOR 800V 16A TO263 |
745 |
|
|
- | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 800 V | 16 A | 1.3 V | 167A, 200A | 35 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
Q6030LH5TPTRIAC ALTERNSTR 600V 30A TO220-3 |
2,747 |
|
|
- | TO-220-3 Isolated Tab | Tube | Active | Alternistor - Snubberless | 600 V | 30 A | 2 V | 290A, 350A | 50 mA | 75 mA | Single | -25°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
|
BTA40-600BTRIAC 600V 40A RD91 |
3,080 |
|
|
- | RD91-3 (Insulated) | Bulk | Active | Standard | 600 V | 40 A | 1.3 V | 400A, 420A | 50 mA | 80 mA | Single | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | RD91 |
|
Q4040K7TPTRIAC ALTERNISTOR 400V 40A TO218 |
278 |
|
|
- | TO-218-3 Isolated Tab, TO-218AC | Tube | Active | Alternistor - Snubberless | 400 V | 40 A | 2 V | 335A, 400A | 100 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-218 Isolated Tab |
|
|
TPDV1240RGTRIAC ALTERNISTOR 1.2KV 40A TOP3 |
1,325 |
|
|
- | TOP-3 | Tube | Active | Alternistor - Snubberless | 1.2 kV | 40 A | 1.5 V | 350A, 370A | 200 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TOP3 |
|
Z0103NN0,135TRIAC SENS GATE 800V 1A SC73 |
3,215 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 1 A | 1.3 V | 12.5A, 13.8A | 3 mA | 7 mA | Single | 125°C (TJ) | - | - | Surface Mount | SC-73 |
|
MAC97A8,412TRIAC SENS GATE 600V 0.6A TO92-3 |
73,105 |
|
|
- | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bulk | Active | Logic - Sensitive Gate | 600 V | 600 mA | 2 V | 8A, 8.8A | 5 mA | 10 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
Z0103MN 5AA4TRIAC SENS GATE 600V 1A SOT223 |
5,818 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.3 V | 8A, 8.5A | 3 mA | 7 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
Z0107MN 5AA4TRIAC SENS GATE 600V 1A SOT223 |
3,988 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.3 V | 8A, 8.5A | 5 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
Z0109NN6AA4TRIAC SENS GATE 800V 1A SOT223 |
5,216 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 1 A | 1.3 V | 8A, 8.5A | 10 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
BT131-600D,412TRIAC SENS GATE 600V 1A TO92-3 |
8,279 |
|
|
- | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bulk | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.5 V | 12.5A, 13.7A | 5 mA | 10 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
Kategorieübersicht
TRIACs Produkte und Auswahlhilfe
TRIACs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie TRIACs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden TRIACs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.