| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Triac-Typ | Spannung - Aus-Zustand | Strom - Einschaltzustand (It (RMS)) (Max) | Spannung - Gate-Trigger (Vgt) (Max) | Strom - Nicht-Rep.-Spannung 50, 60 Hz (Itsm) | Strom - Gate-Trigger (Igt) (Max) | Strom - Halten (Ih) (max.) | Konfiguration | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BCR16CM-12LC#BH0TRIAC 600V 16A TO220ABA |
3,432 |
|
|
- | TO-220-3 | Tube | Active | Standard | 600 V | 16 A | 1.5 V | 96A @ 60Hz | 50 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220ABA |
|
BCR16CM-16LH#BH0TRIAC 800V 16A TO220ABA |
9,912 |
|
|
- | TO-220-3 | Tube | Active | Standard | 800 V | 16 A | 1.5 V | 160A @ 60Hz | 50 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220ABA |
|
BCR20CM-12LB#BH0TRIAC 600V 20A TO220ABA |
5,262 |
|
|
- | TO-220-3 | Tube | Active | Standard | 600 V | 20 A | 1.5 V | 200A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220ABA |
|
BCR5CM-12LB#BH0TRIAC 600V 5A TO220ABA |
2,577 |
|
|
- | TO-220-3 | Tube | Active | Standard | 600 V | 5 A | 1.5 V | 50A @ 60Hz | 20 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220ABA |
|
BCR5CM-12RA#BH0TRIAC 600V 5A TO220ABA |
3,099 |
|
|
- | TO-220-3 | Tube | Active | Standard | 600 V | 5 A | 1.5 V | 50A @ 60Hz | 15 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220ABA |
|
BCR6CM-12RA#BH0TRIAC 600V 6A TO220ABA |
5,765 |
|
|
- | TO-220-3 | Tube | Active | Standard | 600 V | 6 A | 1.5 V | 60A @ 60Hz | 30 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220ABA |
|
BCR8CM-12LB#BH0TRIAC 600V 8A TO220ABA |
9,528 |
|
|
- | TO-220-3 | Tube | Active | Standard | 600 V | 8 A | 1.5 V | 80A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220ABA |
|
BCR4AS-16LH-1T13#B00TRIAC 800V 4A MP3A |
4,345 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Standard | 800 V | 4 A | 1.5 V | 30A @ 60Hz | 35 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | MP-3A |
|
BCR2AS-12A-T13#B00TRIAC SENSITIVE GATE SMD |
7,143 |
|
|
- | - | Tape & Reel (TR) | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
BCR2AS-12A#B00TRIAC SENSITIVE GATE SMD |
4,680 |
|
|
- | - | Tube | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
BCR2AS-14A#B00TRIAC SENS GATE 700V 2A MP3A |
7,972 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Discontinued at Digi-Key | Logic - Sensitive Gate | 700 V | 2 A | 2 V | 9A @ 50Hz | 10 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | MP-3A |
|
BCR3AS-12A#B00TRIAC 600V 3A MP3A |
7,822 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Discontinued at Digi-Key | Standard | 600 V | 3 A | 1.5 V | 30A @ 60Hz | 15 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | MP-3A |
|
BCR3AS-14B#B00TRIAC 800V 3A MP3A |
5,192 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Discontinued at Digi-Key | Standard | 800 V | 3 A | 1.5 V | 30A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | MP-3A |
|
BCR4AS-16LH#B01TRIAC 800V 4A MP3A |
8,494 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Discontinued at Digi-Key | Standard | 800 V | 4 A | 1.5 V | 30A @ 60Hz | 35 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | MP-3A |
|
BCR5AS-12A#B00TRIAC 600V 5A MP3A |
8,895 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Discontinued at Digi-Key | Standard | 600 V | 5 A | 1.5 V | 50A @ 60Hz | 30 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | MP-3A |
|
BCR5AS-12B#B01TRIAC 600V 5A MP3A |
8,994 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Discontinued at Digi-Key | Standard | 600 V | 5 A | 1.5 V | 50A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | MP-3A |
|
BCR5AS-14A#B00TRIAC 700V 5A MP3A |
8,286 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Discontinued at Digi-Key | Standard | 700 V | 5 A | 1.5 V | 50A @ 60Hz | 30 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | MP-3A |
|
BCR08AM-14A#BD0TRIAC SENS GATE 700V 0.8A TO92 |
4,450 |
|
|
- | TO-226-3, TO-92-3 (TO-226AA) | Bag | Active | Logic - Sensitive Gate | 700 V | 800 mA | 2 V | 8A @ 60Hz | 5 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92 |
|
BCR10FM-12LB#BG0TRIAC 600V 10A TO220FPA |
3,389 |
|
|
- | TO-220-3 Full Pack | Tube | Active | Standard | 600 V | 10 A | 1.5 V | 100A @ 50Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FPA |
|
BCR12FM-12LB#BG0TRIAC 600V 12A TO220FPA |
9,597 |
|
|
- | TO-220-3 Full Pack | Tube | Active | Standard | 600 V | 12 A | 1.5 V | 120A @ 50Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FPA |
Kategorieübersicht
TRIACs Produkte und Auswahlhilfe
TRIACs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie TRIACs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden TRIACs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.