TRIACs
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Triac-Typ | Spannung - Aus-Zustand | Strom - Einschaltzustand (It (RMS)) (Max) | Spannung - Gate-Trigger (Vgt) (Max) | Strom - Nicht-Rep.-Spannung 50, 60 Hz (Itsm) | Strom - Gate-Trigger (Igt) (Max) | Strom - Halten (Ih) (max.) | Konfiguration | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BCR5LM-12LB#B00TRIAC 600V 5A TO220FL |
6,571 |
|
|
- | TO-220-3 Full Pack | Tube | Active | Standard | 600 V | 5 A | 1.5 V | 50A @ 60Hz | 20 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FL |
|
BCR08AM-14A-A6#B00TRIAC SENS GATE 700V 0.8A TO92 |
4,807 |
|
|
- | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Logic - Sensitive Gate | 700 V | 800 mA | 2 V | 8A @ 60Hz | 5 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92 |
|
BT137-600/DG,127TRIAC 600V 8A TO220AB |
2,321 |
|
|
- | TO-220-3 | Tube | Discontinued at Digi-Key | Standard | 600 V | 8 A | 1.5 V | 65A, 71A | 35 mA | 20 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
BT138-800E/DG,127TRIAC SENS GATE 800V 12A TO220AB |
3,185 |
|
|
- | TO-220-3 | Tube | Discontinued at Digi-Key | Logic - Sensitive Gate | 800 V | 12 A | 1.5 V | 90A, 100A | 10 mA | 30 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
Q6016LH2TRIAC ALTERNISTOR 600V 16A TO220 |
6,964 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | Alternistor - Snubberless | 600 V | 16 A | 1.3 V | 167A, 200A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
L6008R6TRIAC SENS GATE 600V 8A TO220 |
7,266 |
|
|
- | TO-220-3 | Bulk | Discontinued at Digi-Key | Logic - Sensitive Gate | 600 V | 8 A | 1.3 V | 65A, 85A | 5 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220 Non-Isolated Tab |
|
Q6025LH5TRIAC ALTERNISTOR 600V 25A TO220 |
5,439 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | Alternistor - Snubberless | 600 V | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
L4008L659TRIAC SENS GATE 400V 8A TO220 |
3,396 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | Logic - Sensitive Gate | 400 V | 8 A | 1.3 V | 65A, 85A | 10 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
L6008L659TRIAC SENS GATE 600V 8A TO220 |
6,662 |
|
|
- | TO-220-3 Isolated Tab, Formed Leads | Bulk | Discontinued at Digi-Key | Logic - Sensitive Gate | 600 V | 8 A | 1.3 V | 65A, 85A | 10 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
Q4008RH3TRIAC ALTERNISTOR 400V 8A TO220 |
5,125 |
|
|
- | TO-220-3 | Bulk | Discontinued at Digi-Key | Alternistor - Snubberless | 400 V | 8 A | 1.3 V | 83A, 100A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Non-Isolated Tab |
|
Q4015LT58TRIAC 400V 15A TO220AB |
3,637 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | Standard | - | - | - | - | - | - | - | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
Q6006RH3TRIAC ALTERNISTOR 600V 6A TO220 |
8,812 |
|
|
- | TO-220-3 | Bulk | Discontinued at Digi-Key | Alternistor - Snubberless | 600 V | 6 A | 1.3 V | 80A, 85A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
Q6015LT58TRIAC INT TRIGGER 600V 15A TO220 |
7,148 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | Internally Triggered | 600 V | 15 A | - | 167A, 200A | - | 70 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
TIC216M-STRIAC SENS GATE 600V 6A TO220 |
7,305 |
|
|
- | TO-220-3 | Tube | Obsolete | Logic - Sensitive Gate | 600 V | 6 A | 2.2 V | 60A @ 50Hz | 5 mA | 30 mA | Single | -40°C ~ 110°C (TC) | - | - | Through Hole | TO-220 |
|
TIC225M-STRIAC SENS GATE 600V 8A TO220 |
5,080 |
|
|
- | TO-220-3 | Tube | Obsolete | Logic - Sensitive Gate | 600 V | 8 A | 2 V | 70A @ 50Hz | 5 mA | 20 mA | Single | -40°C ~ 110°C (TC) | - | - | Through Hole | TO-220 |
|
TIC226M-STRIAC 600V 8A TO220 |
9,488 |
|
|
- | TO-220-3 | Tube | Obsolete | Standard | 600 V | 8 A | 2 V | 70A @ 50Hz | 50 mA | 30 mA | Single | -40°C ~ 110°C (TC) | - | - | Through Hole | TO-220 |
|
TIC226N-STRIAC 800V 8A TO220 |
6,198 |
|
|
- | TO-220-3 | Tube | Obsolete | Standard | 800 V | 8 A | 2 V | 70A @ 50Hz | 50 mA | 30 mA | Single | -40°C ~ 110°C (TC) | - | - | Through Hole | TO-220 |
|
TIC246M-STRIAC 600V 16A TO220 |
8,529 |
|
|
- | TO-220-3 | Tube | Obsolete | Standard | 600 V | 16 A | 2 V | 125A @ 50Hz | 50 mA | 40 mA | Single | -40°C ~ 110°C (TC) | - | - | Through Hole | TO-220 |
|
TIC236D-STRIAC 400V 12A TO220 |
6,052 |
|
|
- | TO-220-3 | Tube | Obsolete | Standard | 400 V | 12 A | 2 V | 100A @ 50Hz | 50 mA | 40 mA | Single | -40°C ~ 110°C (TC) | - | - | Through Hole | TO-220 |
|
TIC246D-STRIAC 400V 16A TO220 |
2,674 |
|
|
- | TO-220-3 | Tube | Obsolete | Standard | 400 V | 16 A | 2 V | 125A @ 50Hz | 50 mA | 40 mA | Single | -40°C ~ 110°C (TC) | - | - | Through Hole | TO-220 |
Kategorieübersicht
TRIACs Produkte und Auswahlhilfe
TRIACs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie TRIACs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden TRIACs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.
