SCRs
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Spannung - Aus-Zustand | Spannung - Gate-Trigger (Vgt) (Max) | Strom - Gate-Trigger (Igt) (Max) | Spannung - Einschaltzustand (Vtm) (Max) | Strom - Einschaltzustand (It (AV)) (Max) | Strom - Einschaltzustand (It (RMS)) (Max) | Strom - Halten (Ih) (max.) | Strom - Ausschaltzustand (Max) | Strom - Nicht-Rep.-Spannung 50, 60 Hz (Itsm) | SCR-Typ | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MCR100-6ZL1GSCR 400V 800MA TO92-3 |
2,301 |
|
|
- | TO-226-3, TO-92-3 Long Body, Formed Leads | Cut Tape (CT) | Obsolete | 400 V | 800 mV | 200 µA | 1.7 V | - | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
P0102BA 1AA3SCR 200V 800MA TO92-3 |
9,654 |
|
|
- | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | 200 V | 800 mV | 200 µA | 1.95 V | 500 mA | 800 mA | 5 mA | 10 µA | 7A, 8A | Sensitive Gate | -40°C ~ 125°C | - | - | Through Hole | TO-92-3 |
|
MCR100-6RLRMGSCR 400V 800MA TO92-3 |
7,368 |
|
|
- | TO-226-3, TO-92-3 Long Body, Formed Leads | Cut Tape (CT) | Obsolete | 400 V | 800 mV | 200 µA | 1.7 V | - | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
MCR22-6RLRPGSCR 400V 1.5A TO92-3 |
5,877 |
|
|
- | TO-226-3, TO-92-3 Long Body, Formed Leads | Cut Tape (CT) | Obsolete | 400 V | 800 mV | 200 µA | 1.7 V | - | 1.5 A | 5 mA | 10 µA | 15A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
S8015L56SCR 800V 15A TO220 |
5,283 |
|
|
- | TO-220-3 Isolated Tab, Formed Leads | Bulk | Discontinued at Digi-Key | 800 V | 1.5 V | 30 mA | 1.6 V | 9.5 A | 15 A | 40 mA | 20 µA | 188A, 225A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
T106B11SCR 200V 4A TO202 |
6,786 |
|
|
- | TO-202 Long Tab | Bulk | Obsolete | 200 V | 800 mV | 200 µA | 2.2 V | 2.5 A | 4 A | 5 mA | 2 µA | 16A, 20A | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-202 |
|
T106D2SCR 400V 4A TO202 |
8,080 |
|
|
- | TO-202 Short Tab | Bulk | Obsolete | 400 V | 800 mV | 200 µA | 2.2 V | 2.5 A | 4 A | 5 mA | 2 µA | 16A, 20A | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-202 |
|
T107D2SCR 400V 4A TO202 |
2,043 |
|
|
- | TO-202 Short Tab | Bulk | Obsolete | 400 V | 800 mV | 500 µA | 2.5 V | 2.5 A | 4 A | 6 mA | 2 µA | 16A, 20A | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-202 |
|
2N5064,112SCR 200V 800MA TO92-3 |
7,975 |
|
|
- | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bag | Obsolete | 200 V | 800 mV | 200 µA | 1.71 V | 510 mA | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -65°C ~ 125°C | - | - | Through Hole | TO-92-3 |
|
VS-10TTS08PBFSCR 800V 10A TO220AB |
7,745 |
|
|
- | TO-220-3 | Tube | Discontinued at Digi-Key | 800 V | 1 V | 15 mA | 1.15 V | 6.5 A | 10 A | 30 mA | 1 mA | 95A, 110A | Standard Recovery | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
|
2N5060RLRMSCR 30V 800MA TO92-3 |
4,802 |
|
|
- | TO-226-3, TO-92-3 Long Body, Formed Leads | Tape & Box (TB) | Obsolete | 30 V | 800 mV | 200 µA | 1.7 V | 510 mA | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
2N5060RLRMGSCR 30V 800MA TO92-3 |
6,775 |
|
|
- | TO-226-3, TO-92-3 Long Body, Formed Leads | Tape & Box (TB) | Obsolete | 30 V | 800 mV | 200 µA | 1.7 V | 510 mA | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
2N5062GSCR 100V 800MA TO92-3 |
9,469 |
|
|
- | TO-226-3, TO-92-3 Long Body | Bulk | Obsolete | 100 V | 800 mV | 200 µA | 1.7 V | 510 mA | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
2N5064RLRMSCR 200V 800MA TO92-3 |
9,023 |
|
|
- | TO-226-3, TO-92-3 Long Body, Formed Leads | Tape & Box (TB) | Obsolete | 200 V | 800 mV | 200 µA | 1.7 V | 510 mA | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
2N5064RLRMGSCR 200V 800MA TO92-3 |
6,708 |
|
|
- | TO-226-3, TO-92-3 Long Body, Formed Leads | Tape & Box (TB) | Obsolete | 200 V | 800 mV | 200 µA | 1.7 V | 510 mA | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
2N6400SCR 50V 16A TO220AB |
4,469 |
|
|
- | TO-220-3 | Bulk | Obsolete | 50 V | 1.5 V | 30 mA | 1.7 V | 10 A | 16 A | 40 mA | 10 µA | 160A @ 60Hz | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220AB |
|
2N6509TSCR 800V 25A TO220AB |
8,223 |
|
|
- | TO-220-3 | Tube | Obsolete | 800 V | 1.5 V | 30 mA | 1.8 V | 16 A | 25 A | 40 mA | 10 µA | 250A @ 60Hz | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220AB |
|
C122F1SCR 50V 8A TO220AB |
9,709 |
|
|
- | TO-220-3 | Bulk | Obsolete | 50 V | 1.5 V | 25 mA | 1.83 V | - | 8 A | 30 mA | 10 µA | 90A @ 60Hz | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220AB |
|
MCR100-004SCR 200V 800MA TO92-3 |
5,876 |
|
|
- | TO-226-3, TO-92-3 Long Body | Bulk | Obsolete | 200 V | 800 mV | 200 µA | 1.7 V | - | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
|
MCR100-6GSCR 400V 800MA TO92-3 |
6,253 |
|
|
- | TO-226-3, TO-92-3 Long Body | Box | Obsolete | 400 V | 800 mV | 200 µA | 1.7 V | - | 800 mA | 5 mA | 10 µA | 10A @ 60Hz | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 (TO-226) |
Kategorieübersicht
SCRs Produkte und Auswahlhilfe
SCRs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie SCRs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden SCRs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.