SCRs
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Spannung - Aus-Zustand | Spannung - Gate-Trigger (Vgt) (Max) | Strom - Gate-Trigger (Igt) (Max) | Spannung - Einschaltzustand (Vtm) (Max) | Strom - Einschaltzustand (It (AV)) (Max) | Strom - Einschaltzustand (It (RMS)) (Max) | Strom - Halten (Ih) (max.) | Strom - Ausschaltzustand (Max) | Strom - Nicht-Rep.-Spannung 50, 60 Hz (Itsm) | SCR-Typ | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
K4005EA480SCR 4.8KV W107 |
8,281 |
|
|
- | TO-200AF | Box | Active | 4.8 kV | - | - | - | 4005 A | - | - | - | 43200A @ 50Hz | Standard Recovery | - | - | - | Chassis Mount | W107 |
|
K4005EA520SCR 5.2KV W107 |
3,949 |
|
|
- | TO-200AF | Box | Active | 5.2 kV | - | - | - | 4005 A | - | - | - | 43200A @ 50Hz | Standard Recovery | - | - | - | Chassis Mount | W107 |
|
N5910FA420SCR 4.2KV W118 |
8,901 |
|
|
- | TO-200AF | Box | Active | 4.2 kV | - | - | - | 5910 A | - | - | - | 78000A @ 50Hz | Standard Recovery | - | - | - | Chassis Mount | W118 |
|
N5320FE420SCR 4.2KV W119 |
6,658 |
|
|
- | TO-200AF | Box | Active | 4.2 kV | - | - | - | 5320 A | - | - | - | 78000A @ 50Hz | Standard Recovery | - | - | - | Chassis Mount | W119 |
|
N5320FE450SCR 4.5KV W119 |
4,590 |
|
|
- | TO-200AF | Box | Active | 4.5 kV | - | - | - | 5320 A | - | - | - | 78000A @ 50Hz | Standard Recovery | - | - | - | Chassis Mount | W119 |
|
G3000TF450SCR 4.5MV 2770A W86 |
8,976 |
|
|
- | TO-200AF | Box | Active | 4.5 kV | 1 V | 3 A | 4 V | 1381 A | 2770 A | 40 A | 60 mA | 32000A, 24000A | Standard Recovery | -40°C ~ 125°C | - | - | Chassis Mount | W86 |
|
C3100N65X122XPSA1HIGH POWER THYR / DIO BG-T12026K |
5,111 |
|
|
- | - | Tray | Active | - | - | - | - | - | - | - | - | - | Standard Recovery | - | - | - | - | - |
|
T1503NH80TOHXOSA1SCR 8KV 2770A T15040L-1 |
4,627 |
|
|
- | TO-200AF | Tray | Active | 8 kV | - | - | 3 V | 2560 A | 2770 A | 100 mA | - | 57000A @ 50Hz | Standard Recovery | 120°C (TJ) | - | - | Chassis Mount | BG-T15040L-1 |
|
T2563NH80TOHXOSA1SCR 8KV 3600A T17240L-1 |
5,802 |
|
|
- | TO-200AF | Tray | Active | 8 kV | - | - | 2.95 V | 3330 A | 3600 A | 100 mA | - | 93000A @ 50Hz | Standard Recovery | 120°C (TJ) | - | - | Chassis Mount | BG-T17240L-1 |
|
S6008LSCR 600V 8A TO220 |
5,129 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | 600 V | 1.5 V | 15 mA | 1.6 V | 5.1 A | 8 A | 30 mA | 10 µA | 83A, 100A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
2N5064SCR 200V 800MA TO92-3 |
6,240 |
|
|
- | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | 200 V | 800 mV | 200 µA | 1.7 V | 510 mA | 800 mA | 5 mA | 1 µA | 16A, 20A | Sensitive Gate | -40°C ~ 110°C | - | - | Through Hole | TO-92 |
|
S6006LSCR 600V 6A TO220 |
5,812 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | 600 V | 1.5 V | 15 mA | 1.6 V | 3.8 A | 6 A | 30 mA | 10 µA | 83A, 100A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
S4008LSCR 400V 8A TO220 |
8,341 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | 400 V | 1.5 V | 15 mA | 1.6 V | 5.1 A | 8 A | 30 mA | 10 µA | 83A, 100A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
S6020LSCR 600V 20A TO220 |
6,269 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | 600 V | 1.5 V | 30 mA | 1.6 V | 12.8 A | 20 A | 40 mA | 10 µA | 255A, 300A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
S6010LSCR 600V 10A TO220 |
4,321 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | 600 V | 1.5 V | 15 mA | 1.6 V | 6.4 A | 10 A | 30 mA | 10 µA | 83A, 100A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
S4010LSCR 400V 10A TO220 |
8,801 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | 400 V | 1.5 V | 15 mA | 1.6 V | 6.4 A | 10 A | 30 mA | 10 µA | 83A, 100A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
S6012RSCR 600V 12A TO220 |
5,043 |
|
|
- | TO-220-3 | Bulk | Discontinued at Digi-Key | 600 V | 1.5 V | 20 mA | 1.6 V | 7.6 A | 12 A | 40 mA | 10 µA | 100A, 120A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Non-Isolated Tab |
|
S4020LSCR 400V 20A TO220 |
4,812 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | 400 V | 1.5 V | 30 mA | 1.6 V | 12.8 A | 20 A | 40 mA | 10 µA | 255A, 300A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
S4015LSCR 400V 15A TO220 |
6,930 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Discontinued at Digi-Key | 400 V | 1.5 V | 30 mA | 1.6 V | 9.5 A | 15 A | 40 mA | 10 µA | 188A, 225A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
|
S2008LSCR 200V 8A TO220 |
2,214 |
|
|
- | TO-220-3 Isolated Tab | Bulk | Obsolete | 200 V | 1.5 V | 15 mA | 1.6 V | 5.1 A | 8 A | 30 mA | 10 µA | 83A, 100A | Standard Recovery | -40°C ~ 125°C | - | - | Through Hole | TO-220 Isolated Tab |
Kategorieübersicht
SCRs Produkte und Auswahlhilfe
SCRs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie SCRs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden SCRs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.