SCRs – Module
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Struktur | Anzahl der SCRs, Dioden | Spannung - Aus-Zustand | Strom - Einschaltzustand (It (AV)) (Max) | Strom - Einschaltzustand (It (RMS)) (Max) | Spannung - Gate-Trigger (Vgt) (Max) | Strom - Gate-Trigger (Igt) (Max) | Strom - Nicht-Rep.-Spannung 50, 60 Hz (Itsm) | Strom - Halten (Ih) (max.) | Betriebstemperatur | Klasse | Qualifizierung | Montageart |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
VWO80-08IO7MODULE AC CTLR 3PH 800V PWS-F |
4,735 |
|
|
- | Module | Box | Active | 3-Phase Controller - All SCRs | 6 SCRs | 800 V | 37 A | 59 A | 1 V | 100 mA | 1000A, 1100A | 150 mA | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM4208A2SCR MOD PWR-BLK 800V 25A |
9,207 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - SCR/Diode | 1 SCR, 1 Diode | 800 V | 25 A | 39 A | 3 V | 50 mA | 445A, 490A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM421255SCR MOD PWR-BLK 1200V 55A |
5,829 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - SCR/Diode | 1 SCR, 1 Diode | 1.2 kV | 55 A | 86 A | 2 V | 100 mA | 1000A, 1100A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM421655SCR MOD PWR-BLK 1600V 55A |
7,524 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - SCR/Diode | 1 SCR, 1 Diode | 1.6 kV | 55 A | 86 A | 2 V | 100 mA | 1000A, 1100A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM421690SCR MOD PWR-BLK 1600V 90A |
2,134 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - SCR/Diode | 1 SCR, 1 Diode | 1.6 kV | 90 A | 140 A | 2 V | 100 mA | 1730A, 1800A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM430855SCR MOD DUAL 800V 55A |
2,098 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - All SCRs | 2 SCRs | 800 V | 55 A | 86 A | 3 V | 100 mA | 1000A, 1100A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM430890SCR MOD DUAL 800V 90A |
2,088 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - All SCRs | 2 SCRs | 800 V | 90 A | 140 A | 3 V | 100 mA | 1730A, 1800A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM4308A2SCR MOD DUAL 800V 25A |
2,148 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - All SCRs | 2 SCRs | 800 V | 25 A | 39 A | 3 V | 50 mA | 445A, 490A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM431290SCR MOD DUAL 1200V 90A |
2,477 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - All SCRs | 2 SCRs | 1.2 kV | 90 A | 140 A | 2 V | 100 mA | 1730A, 1800A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM4312A2SCR MOD DUAL 1200V 25A |
3,942 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - All SCRs | 2 SCRs | 1.2 kV | 25 A | 39 A | 3 V | 50 mA | 445A, 490A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM431690SCR MOD DUAL 1600V 90A |
2,278 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - All SCRs | 2 SCRs | 1.6 kV | 90 A | 140 A | 2 V | 100 mA | 1730A, 1800A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CM530820SCR MOD PWR-BLOK 800V 200A |
5,567 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Series Connection - All SCRs | 2 SCRs | 800 V | 200 A | 310 A | 3 V | 100 mA | 3600A, 4000A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CSD3080HSCR MOD SGL PWR-BLOK 800V 400A |
3,000 |
|
|
- | Module | Bulk | Obsolete | Single | 1 SCR | 800 V | 400 A | 620 A | 3 V | 100 mA | 7300A, 8000A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CSD3120HSCR MOD SGL PWR-BLOK 1200V 400A |
4,298 |
|
|
- | Module | Bulk | Obsolete | Single | 1 SCR | 1.2 kV | 400 A | 620 A | 3 V | 100 mA | 7300A, 8000A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
CT230802SCR MOD SPLIT DUAL 800V 20A |
2,494 |
|
|
- | POW-R-BLOK™ Module | Bulk | Obsolete | Independent - All SCRs | 2 SCRs | 800 V | 20 A | 30 A | 3 V | 50 mA | 365A, 400A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
TM400DZ-24SCR PHSE CTRL DL MOD 1200V 400A |
5,573 |
|
|
- | Module | Bulk | Obsolete | Series Connection - SCR/Diode | 1 SCR, 1 Diode | 1.2 kV | 400 A | 620 A | 3 V | 100 mA | 8000A @ 60Hz | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
TM400DZ-2HSCR PHSE CTRL DL MOD 1600V 400A |
2,383 |
|
|
- | Module | Bulk | Obsolete | Series Connection - SCR/Diode | 1 SCR, 1 Diode | 1.6 kV | 400 A | 620 A | 3 V | 100 mA | 8000A @ 60Hz | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
TM400DZ-HSCR PHSE CTRL DL MOD 800V 400A |
9,199 |
|
|
- | Module | Bulk | Obsolete | Series Connection - SCR/Diode | 1 SCR, 1 Diode | 800 V | 400 A | 620 A | 3 V | 100 mA | 8000A @ 60Hz | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
MCA700-12IO1WSCR THRYRISTOR CA 1200V WC-500 |
4,846 |
|
|
- | WC-500 | Tray | Active | Common Anode - All SCRs | 2 SCRs | 1.2 kV | 700 A | 1331 A | - | - | 18200 @ 50MHz | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
|
MCA700-16IO1WSCR THRYRISTOR CA 1600V WC-500 |
2,631 |
|
|
- | WC-500 | Tray | Active | Common Anode - All SCRs | 2 SCRs | 1.6 kV | 700 A | 1331 A | - | - | 18200 @ 50MHz | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount |
Kategorieübersicht
SCRs – Module Produkte und Auswahlhilfe
SCRs – Module werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie SCRs – Module nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden SCRs – Module aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.