Einzeldioden
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Technologie | Spannung - Gleichstromsperrspannung (Vr) (Max) | Strom - Durchschnittlich gleichgerichtet (Io) | Spannung - Vorwärtsspannung (Vf) (Max) @ If | Geschwindigkeit | Sperrerholungszeit (trr) | Strom - Sperrleck @ Vr | Kapazität @ Vr, F | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket | Betriebstemperatur - Sperrschicht |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DSK10BDIODE GEN PURP 100V 1A AXIAL |
8,489 |
|
|
- | Axial | Bulk | Obsolete | Standard | 100 V | 1A | 1.1 V @ 1 A | Standard Recovery >500ns, > 200mA (Io) | - | 10 µA @ 100 V | - | - | - | Through Hole | - | 150°C (Max) |
|
NSR0230P2T5HSCHOTTKY DIODE SOD923 |
56,000 |
|
|
- | SOD-923 | Bulk | Active | Schottky | 30 V | 200mA | 500 mV @ 200 mA | Small Signal =< 200mA (Io), Any Speed | - | 10 µA @ 10 V | - | - | - | Surface Mount | SOD-923 | -55°C ~ 125°C |
|
DSF10TBDIODE GEN PURP 100V 1A DO204AL |
9,388 |
|
|
- | DO-204AL, DO-41, Axial | Bulk | Obsolete | Standard | 100 V | 1A | 1 V @ 1 A | Standard Recovery >500ns, > 200mA (Io) | - | 10 µA @ 100 V | - | - | - | Through Hole | - | 150°C (Max) |
|
SS12T3DIODE SCHOTTKY 20V 1A SMA |
3,472 |
|
|
- | DO-214AC, SMA | Tape & Reel (TR) | Obsolete | Schottky | 20 V | 1A | 470 mV @ 1 A | Fast Recovery =< 500ns, > 200mA (Io) | - | 45 µA @ 20 V | - | - | - | Surface Mount | SMA | -55°C ~ 150°C |
|
DSF10TB-BTDIODE GEN PURP 100V 1A DO204AL |
3,197 |
|
|
- | DO-204AL, DO-41, Axial | Tape & Reel (TR) | Obsolete | Standard | 100 V | 1A | 1 V @ 1 A | Standard Recovery >500ns, > 200mA (Io) | - | 10 µA @ 100 V | - | - | - | Through Hole | - | 150°C (Max) |
|
DSK10C-AT1DIODE GEN PURP 200V 1A AXIAL |
3,571 |
|
|
- | R-1, Axial | Tape & Reel (TR) | Obsolete | Standard | 200 V | 1A | 1.1 V @ 1 A | Standard Recovery >500ns, > 200mA (Io) | - | 10 µA @ 200 V | - | - | - | Through Hole | - | 150°C (Max) |
|
SBS006M-TL-ESCHOTTKY DIODE 0.5A 30V |
30,000 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
1N5401T/RDIODE GEN PURP 100V 3A DO201AD |
30,000 |
|
|
- | DO-201AD, Axial | Tape & Reel (TR) | Active | Standard | 100 V | 3A | 950 mV @ 3 A | Standard Recovery >500ns, > 200mA (Io) | - | 5 µA @ 100 V | 28pF @ 4V, 1MHz | - | - | Through Hole | DO-201AD | -65°C ~ 175°C |
|
DSF10TC-BTDIODE GEN PURP 200V 1A DO204AL |
6,263 |
|
|
- | DO-204AL, DO-41, Axial | Tape & Reel (TR) | Obsolete | Standard | 200 V | 1A | 1 V @ 1 A | Standard Recovery >500ns, > 200mA (Io) | - | 10 µA @ 200 V | - | - | - | Through Hole | - | 150°C (Max) |
|
MUR120DIODE GEN PURP 200V 1A AXIAL |
2,605 |
|
|
SWITCHMODE™ | DO-204AL, DO-41, Axial | Bulk | Obsolete | Standard | 200 V | 1A | 875 mV @ 1 A | Fast Recovery =< 500ns, > 200mA (Io) | 35 ns | 2 µA @ 200 V | - | - | - | Through Hole | Axial | -65°C ~ 175°C |
|
DSF10TCDIODE GEN PURP 200V 1A DO204AL |
8,234 |
|
|
- | DO-204AL, DO-41, Axial | Bulk | Obsolete | Standard | 200 V | 1A | 1 V @ 1 A | Standard Recovery >500ns, > 200mA (Io) | - | 10 µA @ 200 V | - | - | - | Through Hole | - | 150°C (Max) |
|
1N5402T/RDIODE GEN PURP 200V 3A DO201AD |
21,250 |
|
|
- | DO-201AD, Axial | Tape & Reel (TR) | Active | Standard | 200 V | 3A | 950 mV @ 3 A | Standard Recovery >500ns, > 200mA (Io) | - | 5 µA @ 200 V | 28pF @ 4V, 1MHz | - | - | Through Hole | DO-201AD | -65°C ~ 175°C |
|
SS24T3DIODE SCHOTTKY POWER 2A 40V SMB |
18,695 |
|
|
- | DO-214AA, SMB | Bulk | Active | Schottky | 40 V | 2A | 500 mV @ 2 A | Fast Recovery =< 500ns, > 200mA (Io) | - | 400 µA @ 40 V | - | - | - | Surface Mount | SMB | - |
|
DSF10TC-AT1DIODE GEN PURP 200V 1A DO204AL |
7,355 |
|
|
- | DO-204AL, DO-41, Axial | Tape & Reel (TR) | Obsolete | Standard | 200 V | 1A | 1 V @ 1 A | Standard Recovery >500ns, > 200mA (Io) | - | 10 µA @ 200 V | - | - | - | Through Hole | - | 150°C (Max) |
|
SBRA401T3G-VF01DIODE SCHOTTKY SMA |
16,779 |
|
|
* | - | Tape & Reel (TR) | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
BYV96E T/RDIODE AVALANCHE 1KV 1.5A DO15 |
15,000 |
|
|
- | DO-204AC, DO-15, Axial | Tape & Reel (TR) | Active | Avalanche | 1000 V | 1.5A | 1.6 V @ 1.5 A | Fast Recovery =< 500ns, > 200mA (Io) | 300 ns | 5 µA @ 1000 V | - | - | - | Through Hole | DO-15 | 175°C |
|
DSK10E-ET1DIODE GEN PURP 400V 1A AXIAL |
2,076 |
|
|
- | R-1, Axial | Tape & Reel (TR) | Obsolete | Standard | 400 V | 1A | 1.1 V @ 1 A | Standard Recovery >500ns, > 200mA (Io) | - | 10 µA @ 400 V | - | - | - | Through Hole | - | 150°C (Max) |
|
SB05-05NP-AASCHOTTKY DIODE 0.5A 50V |
12,000 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
MUR130GDIODE GEN PURP 300V 1A AXIAL |
2,314 |
|
|
SWITCHMODE™ | DO-204AL, DO-41, Axial | Bulk | Obsolete | Standard | 300 V | 1A | 1.25 V @ 1 A | Fast Recovery =< 500ns, > 200mA (Io) | 75 ns | 5 µA @ 300 V | - | - | - | Through Hole | Axial | -65°C ~ 175°C |
|
MUR140RLDIODE GEN PURP 400V 1A AXIAL |
3,342 |
|
|
SWITCHMODE™ | DO-204AL, DO-41, Axial | Tape & Reel (TR) | Obsolete | Standard | 400 V | 1A | 1.25 V @ 1 A | Fast Recovery =< 500ns, > 200mA (Io) | 75 ns | 5 µA @ 400 V | - | - | - | Through Hole | Axial | -65°C ~ 175°C |
Kategorieübersicht
Einzeldioden Produkte und Auswahlhilfe
Einzeldioden werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Einzeldioden nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Einzeldioden aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.