Einzeldioden
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Technologie | Spannung - Gleichstromsperrspannung (Vr) (Max) | Strom - Durchschnittlich gleichgerichtet (Io) | Spannung - Vorwärtsspannung (Vf) (Max) @ If | Geschwindigkeit | Sperrerholungszeit (trr) | Strom - Sperrleck @ Vr | Kapazität @ Vr, F | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket | Betriebstemperatur - Sperrschicht |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
D711N60TXPSA1DIODE GEN PURP 6KV 1070A |
7,385 |
|
|
- | DO-200AB, B-PUK | Tray | Obsolete | Standard | 6000 V | 1070A | 1.9 V @ 1200 A | Standard Recovery >500ns, > 200mA (Io) | - | 50 mA @ 6000 V | - | - | - | Clamp On | - | -40°C ~ 160°C |
|
D471N85TXPSA1DIODE GEN PURP 8.5KV 760A |
9,672 |
|
|
- | DO-200AB, B-PUK | Bulk | Obsolete | Standard | 8500 V | 760A | 3.2 V @ 1200 A | Standard Recovery >500ns, > 200mA (Io) | - | 50 mA @ 8500 V | - | - | - | Clamp On | - | -40°C ~ 160°C |
|
D450S16TXPSA1DIODE GEN PURP 1.6KV 443A |
8,208 |
|
|
- | DO-200AA, A-PUK | Bulk | Obsolete | Standard | 1600 V | 443A | 2.25 V @ 1200 A | Standard Recovery >500ns, > 200mA (Io) | 6.2 µs | 10 mA @ 1600 V | - | - | - | Clamp On | - | -25°C ~ 180°C |
|
D450S20TXPSA1DIODE GEN PURP 2KV 443A |
2,022 |
|
|
- | DO-200AA, A-PUK | Bulk | Obsolete | Standard | 2000 V | 443A | 2.25 V @ 1200 A | Standard Recovery >500ns, > 200mA (Io) | 6.2 µs | 10 mA @ 2000 V | - | - | - | Clamp On | - | -25°C ~ 180°C |
|
D901S45TDIODE GEN PURP 4.5KV 1225A |
7,487 |
|
|
- | DO-200AD | Bulk | Active | Standard | 4500 V | 1225A | 3.5 V @ 2500 A | Standard Recovery >500ns, > 200mA (Io) | - | 250 mA @ 4500 V | - | - | - | Chassis Mount | - | -40°C ~ 125°C |
|
D371S45TXPSA1DIODE GEN PURP 4.5KV 510A |
5,369 |
|
|
- | DO-200AB, B-PUK | Bulk | Obsolete | Standard | 4500 V | 510A | 3.9 V @ 1200 A | Standard Recovery >500ns, > 200mA (Io) | - | 100 mA @ 4500 V | - | - | - | Clamp On | - | -40°C ~ 125°C |
|
D251K18BXPSA1DIODE GEN PURP 1.8KV 255A |
2,384 |
|
|
- | DO-205AA, DO-8, Stud | Bulk | Obsolete | Standard | 1800 V | 255A | - | Standard Recovery >500ns, > 200mA (Io) | - | 30 mA @ 1800 V | - | - | - | Stud Mount | - | -40°C ~ 180°C |
|
D251N08BXPSA1DIODE GEN PURP 800V 255A |
9,814 |
|
|
- | DO-205AA, DO-8, Stud | Bulk | Obsolete | Standard | 800 V | 255A | - | Standard Recovery >500ns, > 200mA (Io) | - | 30 mA @ 800 V | - | - | - | Stud Mount | - | -40°C ~ 180°C |
|
D251N18BXPSA1DIODE GEN PURP 1.8KV 255A |
7,917 |
|
|
- | DO-205AA, DO-8, Stud | Bulk | Obsolete | Standard | 1800 V | 255A | - | Standard Recovery >500ns, > 200mA (Io) | - | 30 mA @ 1800 V | - | - | - | Stud Mount | - | -40°C ~ 180°C |
|
D251N20BXPSA1DIODE GEN PURP 2KV 255A |
8,146 |
|
|
- | DO-205AA, DO-8, Stud | Bulk | Obsolete | Standard | 2000 V | 255A | - | Standard Recovery >500ns, > 200mA (Io) | - | 30 mA @ 2000 V | - | - | - | Stud Mount | - | -40°C ~ 180°C |
|
D1230N12TXPSA1DIODE GEN PURP 1.2KV 1230A |
6,979 |
|
|
- | DO-200AA, A-PUK | Bulk | Obsolete | Standard | 1200 V | 1230A | 1.063 V @ 800 A | Standard Recovery >500ns, > 200mA (Io) | - | 50 mA @ 1200 V | - | - | - | Clamp On | - | -40°C ~ 180°C |
|
D1050N12TXPSA1DIODE GEN PURP 1.2KV 1050A |
8,459 |
|
|
- | DO-200AB, B-PUK | Bulk | Obsolete | Standard | 1200 V | 1050A | 1 V @ 1000 A | Standard Recovery >500ns, > 200mA (Io) | - | 60 mA @ 1200 V | - | - | - | Clamp On | - | -40°C ~ 180°C |
|
D121N12BXPSA1DIODE GEN PURP 1.2KV 230A |
3,358 |
|
|
- | DO-205AA, DO-8, Stud | Bulk | Obsolete | Standard | 1200 V | 230A | - | Standard Recovery >500ns, > 200mA (Io) | - | 20 mA @ 1200 V | - | - | - | Stud Mount | - | -40°C ~ 180°C |
|
D1030N24TXPSA1DIODE GEN PURP 2.4KV 1030A |
5,412 |
|
|
- | DO-200AB, B-PUK | Bulk | Obsolete | Standard | 2400 V | 1030A | 1.11 V @ 10000 A | Standard Recovery >500ns, > 200mA (Io) | - | 40 mA @ 2400 V | - | - | - | Clamp On | - | -40°C ~ 160°C |
|
D270N36TXPSA1DIODE GEN PURP 3.6KV 270A |
6,987 |
|
|
- | DO-200AB, B-PUK | Bulk | Obsolete | Standard | 3600 V | 270A | 1.36 V @ 250 A | Standard Recovery >500ns, > 200mA (Io) | - | 20 mA @ 3600 V | - | - | - | Clamp On | - | -40°C ~ 150°C |
|
D2450N07TXPSA1DIODE GEN PURP 700V 2450A |
8,700 |
|
|
- | DO-200AB, B-PUK | Tray | Discontinued at Digi-Key | Standard | 700 V | 2450A | 880 mV @ 2000 A | Standard Recovery >500ns, > 200mA (Io) | - | 50 mA @ 700 V | - | - | - | Clamp On | - | -40°C ~ 180°C |
|
D1800N36TVFXPSA1DIODE GEN PURP 3.6KV 1800A |
4,539 |
|
|
- | DO-200AC, K-PUK | Bulk | Obsolete | Standard | 3600 V | 1800A | 1.32 V @ 1500 A | Standard Recovery >500ns, > 200mA (Io) | - | 100 mA @ 3600 V | - | - | - | Clamp On | - | -40°C ~ 160°C |
|
D1481N62TXPSA1DIODE GEN PURP 6.2KV 2200A |
2,597 |
|
|
- | DO-200AC, K-PUK | Bulk | Obsolete | Standard | 6200 V | 2200A | 1.8 V @ 2500 A | Standard Recovery >500ns, > 200mA (Io) | - | 50 mA @ 6200 V | - | - | - | Clamp On | - | -40°C ~ 160°C |
|
D1481N65TXPSA1DIODE GEN PURP 6.5KV 2200A |
5,370 |
|
|
- | DO-200AC, K-PUK | Bulk | Obsolete | Standard | 6500 V | 2200A | 1.8 V @ 2500 A | Standard Recovery >500ns, > 200mA (Io) | - | 50 mA @ 6500 V | - | - | - | Clamp On | - | -40°C ~ 160°C |
|
D1481N68TXPSA1DIODE GEN PURP 6.8KV 2200A |
9,056 |
|
|
- | DO-200AC, K-PUK | Tray | Obsolete | Standard | 6800 V | 2200A | 1.8 V @ 2500 A | Standard Recovery >500ns, > 200mA (Io) | - | 50 mA @ 6800 V | - | - | - | Clamp On | - | -40°C ~ 160°C |
Kategorieübersicht
Einzeldioden Produkte und Auswahlhilfe
Einzeldioden werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Einzeldioden nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Einzeldioden aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.