Einzel-IGBTs
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | IGBT-Typ | Spannung - Kollektor-Emitter-Durchbruch (Max) | Strom - Kollektor (Ic) (Max) | Strom - Kollektor gepulst (Icm) | Vce(ein) (Max) @ Vge, Ic | Leistung – Max | Schaltenergie | Eingabetyp | Gate-Ladung | Td (ein/aus) @ 25°C | Testbedingung | Sperrerholungszeit (trr) | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
STGWA60H65DFBIGBT BIPO 650V 60A TO247-3 |
3,069 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 240 A | 2V @ 15V, 60A | 375 W | 1.59mJ (on), 900µJ (off) | Standard | 306 nC | 66ns/210ns | 400V, 60A, 10Ohm, 15V | 60 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
AIGB40N65F5ATMA1DISCRETE SWITCHES |
6,971 |
|
|
- | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | NPT | 650 V | 40 A | - | - | - | - | Standard | - | - | - | - | - | - | - | Surface Mount | PG-TO263-3-2 |
|
IXXH50N60C3D1IGBT 600V 100A 600W TO247AD |
7,649 |
|
|
GenX3™, XPT™ | TO-247-3 | Tube | Active | PT | 600 V | 100 A | 200 A | 2.3V @ 15V, 36A | 600 W | 720µJ (on), 330µJ (off) | Standard | 64 nC | 24ns/62ns | 360V, 36A, 5Ohm, 15V | 25 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247AD (IXXH) |
|
STGW25H120F2IGBT TRENCH FS 1200V 50A TO247-3 |
18 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 50 A | 100 A | 2.6V @ 15V, 25A | 375 W | 600µJ (on), 700µJ (off) | Standard | 100 nC | 29ns/130ns | 600V, 25A, 10Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
AIKW40N65DF5XKSA1IC DISCRETE 650V TO247-3 |
7,331 |
|
|
Trenchstop™ 5 | TO-247-3 | Tube | Active | Trench | 650 V | 74 A | 120 A | 2.1V @ 15V, 40A | 250 W | 350µJ (on), 100µJ (off) | Standard | 95 nC | 19ns/165ns | 400V, 20A, 15Ohm, 15V | - | -40°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Through Hole | PG-TO247-3-41 |
|
AIKW40N65DH5XKSA1IC DISCRETE 650V TO247-3 |
3,709 |
|
|
Trenchstop™ 5 | TO-247-3 | Tube | Active | Trench | 650 V | 74 A | 120 A | 2.1V @ 15V, 40A | 250 W | 350µJ (on), 100µJ (off) | Standard | 95 nC | 19ns/165ns | 400V, 20A, 15Ohm, 15V | - | -40°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Through Hole | PG-TO247-3-41 |
|
STGWA40IH65DFTRENCH GATE FIELD-STOP 650 V 40 |
2,555 |
|
|
IH | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 120 A | 2V @ 15V, 40A | 238 W | 190µJ (off) | Standard | 114 nC | -/210ns | 400V, 40A, 22Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 Long Leads |
|
RGT80TS65DGC11IGBT 650V 70A 234W TO-247N |
5 |
|
|
- | TO-247-3 | Tube | Not For New Designs | Trench Field Stop | 650 V | 70 A | 120 A | 2.1V @ 15V, 40A | 234 W | - | Standard | 79 nC | 34ns/119ns | 400V, 40A, 10Ohm, 15V | 58 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
|
IKW30N65EL5XKSA1IGBT 650V 85A TO247-3 |
16 |
|
|
TrenchStop™ 5 | TO-247-3 | Tube | Active | - | 650 V | 85 A | 120 A | 1.35V @ 15V, 30A | 227 W | 470µJ (on), 1.35mJ (off) | Standard | 168 nC | 33ns/308ns | 400V, 30A, 10Ohm, 15V | 100 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3 |
|
STGW50H65DFB2-4TRENCH GATE FIELD-STOP, 650 V, 5 |
7,645 |
|
|
HB2 | TO-247-4 | Tube | Active | Trench Field Stop | 650 V | 86 A | 150 A | 2V @ 15V, 50A | 272 W | 629µJ (on), 478µJ (off) | Standard | 151 nC | 18ns/128ns | 400V, 50A, 12Ohm, 15V | 92 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-4 |
|
IKQ100N60TXKSA1IGBT TRENCH/FS 600V 160A TO247-3 |
4,563 |
|
|
TrenchStop™ | TO-247-3 | Tube | Active | Trench Field Stop | 600 V | 160 A | 400 A | 2V @ 15V, 100A | 714 W | 3.1mJ (on), 2.5mJ (off) | Standard | 610 nC | 30ns/290ns | 400V, 100A, 3.6Ohm, 15V | 230 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3-46 |
|
AIKW50N65DH5XKSA1IC DISCRETE 650V TO247-3 |
5,878 |
|
|
Trenchstop™ 5 | TO-247-3 | Tube | Active | Trench | 650 V | - | 150 A | 2.1V @ 15V, 50A | 270 W | 490µJ (on), 140µJ (off) | Standard | 1018 nC | 21ns/156ns | 400V, 25A, 12Ohm, 15V | - | -40°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Through Hole | PG-TO247-3-41 |
|
RGCL80TS60DGC11IGBT TRNCH FIELD 600V 65A TO247N |
5,704 |
|
|
- | TO-247-3 | Bulk | Not For New Designs | Trench Field Stop | 600 V | 65 A | 160 A | 1.8V @ 15V, 40A | 148 W | 1.11mJ (on), 1.68mJ (off) | Standard | 98 nC | 53ns/227ns | 400V, 40A, 10Ohm, 15V | 58 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
STGWA25H120F2IGBT HB 1200V 25A HS TO247-3 |
8,887 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 50 A | 100 A | 2.6V @ 15V, 25A | 375 W | 600µJ (on), 700µJ (off) | Standard | 100 nC | 29ns/130ns | 600V, 25A, 10Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
STGWA15S120DF3IGBT 1200V 15A TO247-3L |
9,323 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 30 A | 60 A | 2.05V @ 15V, 15A | 259 W | 540µJ (on), 1.38mJ (off) | Standard | 53 nC | 23ns/140ns | 600V, 15A, 22Ohm, 15V | 270 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
RGW00TS65GC11IGBT TRNCH FIELD 650V 96A TO247N |
9,955 |
|
|
- | TO-247-3 | Tube | Not For New Designs | Trench Field Stop | 650 V | 96 A | 200 A | 1.9V @ 15V, 50A | 254 W | 1.18mJ (on), 960µJ (off) | Standard | 141 nC | 52ns/180ns | 400V, 50A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RGTV60TS65DGC11IGBT TRNCH FIELD 650V 60A TO247N |
3,805 |
|
|
- | TO-247-3 | Tube | Not For New Designs | Trench Field Stop | 650 V | 60 A | 120 A | 1.9V @ 15V, 30A | 194 W | 570µJ (on), 500µJ (off) | Standard | 64 nC | 33ns/105ns | 400V, 30A, 10Ohm, 15V | 95 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RGS60TS65HRC11IGBT TRNCH FIELD 650V 56A TO247N |
3,162 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 56 A | 90 A | 2.1V @ 15V, 30A | 223 W | 660µJ (on), 810µJ (off) | Standard | 36 nC | 28ns/104ns | 400V, 30A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
IXYH40N120C3D1IGBT 1200V 64A 480W TO247 |
2,396 |
|
|
GenX3™, XPT™ | TO-247-3 | Tube | Active | - | 1200 V | 64 A | 105 A | 4V @ 15V, 40A | 480 W | 3.9mJ (on), 660µJ (off) | Standard | 85 nC | 24ns/125ns | 600V, 40A, 10Ohm, 15V | 195 ns | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-247 (IXTH) |
|
IXDR30N120D1IGBT 1200V 50A 200W ISOPLUS247 |
8,495 |
|
|
- | TO-247-3 | Tube | Active | NPT | 1200 V | 50 A | 60 A | 2.9V @ 15V, 30A | 200 W | 4.6mJ (on), 3.4mJ (off) | Standard | 120 nC | - | 600V, 30A, 47Ohm, 15V | 40 ns | -55°C ~ 150°C (TJ) | - | - | Through Hole | ISOPLUS247™ |
Kategorieübersicht
Einzel-IGBTs Produkte und Auswahlhilfe
Einzel-IGBTs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Einzel-IGBTs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Einzel-IGBTs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.