Einzel-IGBTs
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | IGBT-Typ | Spannung - Kollektor-Emitter-Durchbruch (Max) | Strom - Kollektor (Ic) (Max) | Strom - Kollektor gepulst (Icm) | Vce(ein) (Max) @ Vge, Ic | Leistung – Max | Schaltenergie | Eingabetyp | Gate-Ladung | Td (ein/aus) @ 25°C | Testbedingung | Sperrerholungszeit (trr) | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ISL9V3040S3STIGBT 430V 21A TO263AB |
2,798 |
|
|
EcoSPARK® | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | - | 430 V | 21 A | - | 1.6V @ 4V, 6A | 150 W | - | Logic | 17 nC | -/4.8µs | 300V, 1kOhm, 5V | - | -40°C ~ 175°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
IKB30N65ES5ATMA1IGBT TRENCH FS 650V 62A TO263-3 |
2,794 |
|
|
TrenchStop™ 5 | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench Field Stop | 650 V | 62 A | 120 A | 1.7V @ 15V, 30A | 188 W | 560µJ (on), 320µJ (off) | Standard | 70 nC | 17ns/124ns | 400V, 30A, 13Ohm, 15V | 75 ns | -40°C ~ 175°C (TJ) | - | - | Surface Mount | PG-TO263-3 |
|
|
STGP20NC60VIGBT 600V 60A TO220 |
490 |
|
|
PowerMESH™ | TO-220-3 | Tube | Active | - | 600 V | 60 A | 100 A | 2.5V @ 15V, 20A | 200 W | 220µJ (on), 330µJ (off) | Standard | 100 nC | 31ns/100ns | 390V, 20A, 3.3Ohm, 15V | - | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-220 |
|
AOK20B135D1IGBT 1350V 40A 340W TO-247 |
158 |
|
|
Alpha IGBT™ | TO-247-3 | Tube | Not For New Designs | - | 1350 V | 40 A | 80 A | 1.8V @ 15V, 20A | 340 W | 1.05mJ (off) | Standard | 66 nC | -/156ns | 600V, 20A, 15Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 |
|
IKWH50N65WR6XKSA1IGBT TRENCH FS 650V 85A TO247-3 |
198 |
|
|
TrenchStop™ 5 WR6 | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 85 A | 150 A | 1.85V @ 15V, 50A | 205 W | 1.5mJ (on), 730µJ (off) | Standard | 144 nC | 40ns/351ns | 400V, 50A, 22Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3-32 |
|
FGA40T65SHDIGBT TRENCH FS 650V 80A TO3PN |
431 |
|
|
- | TO-3P-3, SC-65-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 120 A | 2.1V @ 15V, 40A | 268 W | 1.01mJ (on), 297µJ (off) | Standard | 72.2 nC | 19.2ns/65.6ns | 400V, 40A, 6Ohm, 15V | 31.8 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-3PN |
|
AOK30B135W1IGBT 1350V 30A 170W TO247 |
205 |
|
|
Alpha IGBT™ | TO-247-3 | Tube | Not For New Designs | - | 1350 V | 60 A | 200 A | 2.2V @ 15V, 30A | 340 W | 1.47mJ (off) | Standard | 62 nC | -/129ns | 600V, 30A, 10Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 |
|
|
IGW30N65L5XKSA1IGBT TRENCH 650V 85A TO247-3 |
792 |
|
|
TrenchStop™ 5 | TO-247-3 | Tube | Active | - | 650 V | 85 A | 120 A | 1.35V @ 15V, 30A | 227 W | 470µJ (on), 1.35mJ (off) | Standard | 168 nC | 33ns/308ns | 400V, 30A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3 |
|
|
IXGP48N60A3IGBT PT 600V 120A TO220 |
298 |
|
|
GenX3™ | TO-220-3 | Tube | Active | PT | 600 V | 120 A | 300 A | 1.35V @ 15V, 32A | 300 W | 950µJ (on), 2.9mJ (off) | Standard | 110 nC | 25ns/334ns | 480V, 32A, 5Ohm, 15V | 30 ns | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-220 |
|
FGHL50T65SQIGBT 650V 100A TO247-3 |
621 |
|
|
- | TO-247-3 | Tube | Active | - | 650 V | 100 A | 200 A | 2.1V @ 15V, 50A | 268 W | 410µJ (on), 88µJ (off) | Standard | 99 nC | 19ns/93ns | 400V, 25A, 4.7Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
STGWT40H65DFBIGBT TRENCH FS 650V 80A TO3P |
222 |
|
|
- | TO-3P-3, SC-65-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 160 A | 2V @ 15V, 40A | 283 W | 498µJ (on), 363µJ (off) | Standard | 210 nC | 40ns/142ns | 400V, 40A, 5Ohm, 15V | 62 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-3P |
|
|
STGYA50H120DF2IGBT TRENCH FS 1200V 100A TO247 |
435 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 100 A | 200 A | 2.6V @ 15V, 50A | 535 W | 2mJ (on), 2.1mJ (off) | Standard | 210 nC | 40ns/284ns | 600V, 50A, 10Ohm, 15V | 340 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 |
|
FGH40T65SHDF-F155IGBT FIELD STOP 650V 80A TO247-3 |
403 |
|
|
- | TO-247-3 | Tube | Active | Field Stop | 650 V | 80 A | 120 A | 1.81V @ 15V, 40A | 268 W | 1.22mJ (on), 440µJ (off) | Standard | 68 nC | 18ns/64ns | 400V, 40A, 6Ohm, 15V | 101 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
FGB3245G2-F085ECOSPARK2 450V IGNITION IGBT |
686 |
|
|
EcoSPARK® | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | - | 450 V | 23 A | - | 1.25V @ 4V, 6A | 150 W | - | Logic | 23 nC | 900ns/5.4µs | - | - | -40°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Surface Mount | TO-263 (D2PAK) |
|
FGH40T65SHD-F155IGBT TRENCH FS 650V 80A TO247-3 |
2,052 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 120 A | 2.1V @ 15V, 40A | 268 W | 1.01mJ (on), 297µJ (off) | Standard | 72.2 nC | 19.2ns/65.6ns | 400V, 40A, 6Ohm, 15V | 31.8 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
RJH60T04DPQ-A1#T0IGBT TRENCH 600V 60A TO247A |
580 |
|
|
- | TO-247-3 | Tube | Active | Trench | 600 V | 60 A | - | 1.95V @ 15V, 30A | 208.3 W | - | Standard | 87 nC | 54ns/136ns | 400V, 30A, 10Ohm, 15V | 100 ns | 150°C (TJ) | - | - | Through Hole | TO-247A |
|
STGW8M120DF3IGBT TRENCH FS 1200V 16A TO247-3 |
366 |
|
|
M | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 16 A | 32 A | 2.3V @ 15V, 8A | 167 W | 390µJ (on), 370µJ (Off) | Standard | 32 nC | 20ns/126ns | 600V, 8A, 33Ohm, 15V | 103 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
STGW25H120DF2IGBT H-SERIES 1200V 25A TO-247 |
491 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 50 A | 100 A | 2.6V @ 15V, 25A | 375 W | 600µJ (on), 700µJ (off) | Standard | 100 nC | 29ns/130ns | 600V, 25A, 10Ohm, 15V | 303 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
STGWT60H65DFBIGBT TRENCH FS 650V 80A TO3P |
161 |
|
|
- | TO-3P-3, SC-65-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 240 A | 2V @ 15V, 60A | 375 W | 1.09mJ (on), 626µJ (off) | Standard | 306 nC | 51ns/160ns | 400V, 60A, 5Ohm, 15V | 60 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-3P |
|
IKWH60N65WR6XKSA1IGBT TRENCH FS 650V 100A TO247-3 |
106 |
|
|
TrenchStop™ 5 WR6 | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 100 A | 180 A | 1.85V @ 15V, 60A | 240 W | 1.82mJ (on), 850µJ (off) | Standard | 174 nC | 35ns/311ns | 400V, 60A, 15Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3-32 |
Kategorieübersicht
Einzel-IGBTs Produkte und Auswahlhilfe
Einzel-IGBTs werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Einzel-IGBTs nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Einzel-IGBTs aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.