IGBT Module
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | IGBT-Typ | Konfiguration | Spannung - Kollektor-Emitter-Durchbruch (Max) | Strom - Kollektor (Ic) (Max) | Leistung – Max | Vce(ein) (Max) @ Vge, Ic | Strom - Kollektor-Abschaltung (Max) | Eingangskapazität (Cies) @ Vce | Eingang | NTC-Thermistor | Betriebstemperatur | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
APTCV40H60CT1GIGBT MODULE 600V 80A 176W SP1 |
5,673 |
|
|
- | SP1 | Bulk | Active | Trench Field Stop | Full Bridge | 600 V | 80 A | 176 W | 1.9V @ 15V, 50A | 250 µA | 3.15 nF @ 25 V | Standard | Yes | -40°C ~ 150°C (TJ) | Chassis Mount | SP1 |
|
|
APTGT75H60T1GIGBT MODULE 600V 100A 250W SP1 |
7,312 |
|
|
- | SP1 | Bulk | Active | Trench Field Stop | Full Bridge Inverter | 600 V | 100 A | 250 W | 1.9V @ 15V, 75A | 250 µA | 4.62 nF @ 25 V | Standard | Yes | -40°C ~ 175°C (TJ) | Chassis Mount | SP1 |
|
APTGT30X60T3GIGBT MODULE 600V 50A 90W SP3 |
9,541 |
|
|
- | SP3 | Bulk | Active | Trench Field Stop | Three Phase Inverter | 600 V | 50 A | 90 W | 1.9V @ 15V, 30A | 250 µA | 1.6 nF @ 25 V | Standard | Yes | -40°C ~ 175°C (TJ) | Chassis Mount | SP3 |
|
FP30R06YE3B4BOMA1IGBT MODULE LOW PWR EASY2-1 |
7,768 |
|
|
- | - | Tray | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FS150R12N2T7BPSA2LOW POWER ECONO |
8,218 |
|
|
EconoPACK™ 2 | Module | Tray | Active | Trench Field Stop | Three Phase Inverter | 1200 V | 150 A | - | 1.8V @ 15V, 150A | 1.2 µA | 30.1 nF @ 25 V | Standard | Yes | -40°C ~ 175°C (TJ) | Chassis Mount | AG-ECONO2 |
|
|
APTGT50DDA120T3GIGBT MODULE 1200V 75A 270W SP3 |
7,788 |
|
|
- | SP3 | Bulk | Active | Trench Field Stop | Dual Boost Chopper | 1200 V | 75 A | 270 W | 2.1V @ 15V, 50A | 250 µA | 3.6 nF @ 25 V | Standard | Yes | -40°C ~ 175°C (TJ) | Chassis Mount | SP3 |
|
MKI75-12E8IGBT MODULE 1200V 130A 500W E3 |
4,285 |
|
|
- | E3 | Box | Obsolete | NPT | Full Bridge Inverter | 1200 V | 130 A | 500 W | 2.5V @ 15V, 75A | 1.1 mA | 5.7 nF @ 25 V | Standard | No | -40°C ~ 125°C (TJ) | Chassis Mount | E3 |
|
APTGL325DA120D3GIGBT MODULE 1200V 420A 1500W D3 |
4,060 |
|
|
- | D-3 Module | Bulk | Obsolete | Trench Field Stop | Single | 1200 V | 420 A | 1500 W | 2.2V @ 15V, 300A | 5 mA | 18.6 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | D3 |
|
APTGL325SK120D3GIGBT MODULE 1200V 420A 1500W D3 |
5,447 |
|
|
- | D-3 Module | Bulk | Obsolete | Trench Field Stop | Single | 1200 V | 420 A | 1500 W | 2.2V @ 15V, 300A | 5 mA | 18.6 nF @ 25 V | Standard | No | -40°C ~ 175°C (TJ) | Chassis Mount | D3 |
|
MIXG360RF1200P-PCIGBT MODULE MIXG360RF1200PTED-PC |
5,057 |
|
|
- | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FS150R12N2T7B15BPSA1LOW POWER ECONO |
6,943 |
|
|
EconoPACK™ 2 | Module | Tray | Active | Trench Field Stop | Full Bridge Inverter | 1200 V | 150 A | - | 1.8V @ 15V, 150A | 12 µA | 30.1 nF @ 25 V | Standard | Yes | -40°C ~ 175°C (TJ) | Chassis Mount | AG-ECONO2B |
|
APTGF360U60D4GIGBT MODULE 600V 450A 1560W D4 |
9,544 |
|
|
- | D4 | Bulk | Obsolete | NPT | Single | 600 V | 450 A | 1560 W | 2.45V @ 15V, 360A | 500 µA | 17 nF @ 25 V | Standard | No | - | Chassis Mount | D4 |
|
|
APTGF150DU120TGIGBT MODULE 1200V 200A 961W SP4 |
8,894 |
|
|
- | SP4 | Bulk | Obsolete | NPT | Dual, Common Source | 1200 V | 200 A | 961 W | 3.7V @ 15V, 150A | 350 µA | 10.2 nF @ 25 V | Standard | Yes | - | Chassis Mount | SP4 |
|
APTGT300DA120D3GIGBT MODULE 1200V 440A 1250W D3 |
5,836 |
|
|
- | D-3 Module | Bulk | Obsolete | Trench Field Stop | Single | 1200 V | 440 A | 1250 W | 2.1V @ 15V, 300A | 8 mA | 20 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | D3 |
|
APTGT300SK120D3GIGBT MODULE 1200V 440A 1250W D3 |
8,500 |
|
|
- | D-3 Module | Bulk | Obsolete | Trench Field Stop | Single | 1200 V | 440 A | 1250 W | 2.1V @ 15V, 300A | 8 mA | 20 nF @ 25 V | Standard | No | -40°C ~ 150°C (TJ) | Chassis Mount | D3 |
|
APTGT50TL60T3GIGBT MODULE 600V 80A 176W SP3 |
6,992 |
|
|
- | SP3 | Bulk | Active | Trench Field Stop | Three Level Inverter | 600 V | 80 A | 176 W | 1.9V @ 15V, 50A | 250 µA | 3.15 nF @ 25 V | Standard | Yes | -40°C ~ 175°C (TJ) | Chassis Mount | SP3 |
|
|
APTGF150A120TGIGBT MODULE 1200V 200A 961W SP4 |
7,459 |
|
|
- | SP4 | Bulk | Obsolete | NPT | Half Bridge | 1200 V | 200 A | 961 W | 3.7V @ 15V, 150A | 350 µA | 10.2 nF @ 25 V | Standard | Yes | - | Chassis Mount | SP4 |
|
FP50R12N2T7B76BPSA1LOW POWER ECONO |
6,319 |
|
|
- | Module | Tray | Active | Trench Field Stop | Three Phase Inverter | 1200 V | 50 A | - | 1.5V @ 15V, 50A | 10 µA | 11100 pF @ 25 V | Three Phase Bridge Rectifier | Yes | -40°C ~ 175°C (TJ) | Chassis Mount | AG-ECONO2B |
|
|
APTGT75A120T1GIGBT MODULE 1200V 110A 357W SP1 |
7,219 |
|
|
- | SP1 | Bulk | Active | Trench Field Stop | Half Bridge | 1200 V | 110 A | 357 W | 2.1V @ 15V, 75A | 250 µA | 5.34 nF @ 25 V | Standard | Yes | -40°C ~ 150°C (TJ) | Chassis Mount | SP1 |
|
|
CM150DX-24AIGBT MOD 1200V 150A 960W |
7,138 |
|
|
IGBTMOD™ | Module | Bulk | Obsolete | - | Half Bridge | 1200 V | 150 A | 960 W | 2.6V @ 15V, 150A | 1 mA | 23 nF @ 10 V | Standard | Yes | -40°C ~ 150°C (TJ) | Chassis Mount | Module |
Kategorieübersicht
IGBT Module Produkte und Auswahlhilfe
IGBT Module werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie IGBT Module nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden IGBT Module aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.