Sicherungen
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Verpackung/Gehäuse | Serie | Verpackung | Produktstatus | Montageart | Sicherungstyp | Stromstärke (Ampere) | Spannungsstärke - Wechselstrom | Spannungsstärke - Gleichstrom | Reaktionszeit | Ausschaltvermögen bei Nennspannung | Schmelz I²t | Zulassungsstelle | Betriebstemperatur | Farbe | Größe/Abmessung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0322001.HXPFUSE CERM 1A 250VAC 125VDC 3AB |
7,970 |
|
|
322 | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 1 A | 250 V | 125 V | Fast Blow | 100A | 0.1 | CE, cULus, PSE | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0322002.HXPFUSE CERM 2A 250VAC 125VDC 3AB |
4,238 |
|
|
322 | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 2 A | 250 V | 125 V | Fast Blow | 100A | 0.56 | CE, cULus, PSE | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0322004.HXPFUSE CERM 4A 250VAC 125VDC 3AB |
3,278 |
|
|
322 | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 4 A | 250 V | 125 V | Fast Blow | 100A | 3.36 | CE, cULus, PSE | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0322005.HXPFUSE CERM 5A 250VAC 125VDC 3AB |
9,679 |
|
|
322 | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 5 A | 250 V | 125 V | Fast Blow | 100A | 6.25 | CE, cULus, PSE | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0322007.HXPFUSE CERM 7A 250VAC 125VDC 3AB |
4,559 |
|
|
322 | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 7 A | 250 V | 125 V | Fast Blow | 100A | 10.58 | CE, cULus, PSE | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0322008.HXPFUSE CERM 8A 250VAC 125VDC 3AB |
7,761 |
|
|
322 | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 8 A | 250 V | 125 V | Fast Blow | 100A | 16.45 | CE, cULus, PSE | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0322010.HXPFUSE CERM 10A 250VAC 125VDC 3AB |
7,126 |
|
|
322 | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 10 A | 250 V | 125 V | Fast Blow | 100A | 24.0 | CE, cULus, PSE | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
919582FUSE 5X20MM 1A 250V FST G |
2,347 |
|
|
- | - | Active | - | - | - | - | - | - | - | - | - | - | - | - | |
|
BK/AGC-7-1/2NXFUSE GLASS 7.5A 250VAC 3AB 3AG |
4,361 |
|
|
AGC | Bulk | Active | Requires Holder | Cartridge, Glass | 7.5 A | 250 V | - | Fast Blow | 200A | 216.0 | CSA, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0314006.VXPFUSE CERM 6A 250VAC 125VDC 3AB |
4,761 |
|
|
314 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 6 A | 250 V | 125 V | Fast Blow | 750A AC, 10kA DC | 45.0 | CE, CSA, KC, PSE, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
|
BK1/TDC10-60-RFUSE GLASS 60MA 1000VAC 3AB 3AG |
8,722 |
|
|
TDC10 | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 60 mA | 1000 V | - | Fast Blow | 600mA | - | - | - | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
GGM3/4FUSE,FAST ACTING,ELECTRONIC,GLAS |
3,330 |
|
|
GGM | Box | Obsolete | Requires Holder | Cartridge, Glass | 750 mA | 125 V | - | Fast Blow | - | - | CSA, UL, UR | - | - | 0.197" Dia x 0.787" L (5.00mm x 20.00mm) | |
|
0460002.ERFUSE BRD MNT 2A 125VAC/VDC 2SMD |
4,485 |
|
|
PICO® 460 | Tape & Reel (TR) | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 2 A | 125 V | 125 V | Slow Blow | 50A | 7.6 | CSA, PSE, UL | -55°C ~ 125°C | - | 0.285" L x 0.170" W x 0.120" H (7.24mm x 4.32mm x 3.05mm) | |
|
BK/MDL-3/8FUSE GLASS 375MA 250VAC 3AB 3AG |
2,435 |
|
|
MDL | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 375 mA | 250 V | - | Slow Blow | 35A | 0.982 | CSA, UL | - | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0AGA020.VPFUSE GLASS 20A 32VAC/VDC 5PK CRD |
4,721 |
|
|
AGA | Bulk | Active | Requires Holder | Cartridge, Glass | 20 A | 32 V | 32 V | - | - | - | - | - | - | 0.250" Dia x 0.625" L (6.35mm x 15.88mm) | |
|
0AGA010.VPFUSE GLASS 10A 32VAC/VDC 5PK CRD |
6,299 |
|
|
AGA | Bulk | Active | Requires Holder | Cartridge, Glass | 10 A | 32 V | 32 V | - | - | - | - | - | - | 0.250" Dia x 0.625" L (6.35mm x 15.88mm) | |
|
0AGA030.VPFUSE GLASS 30A 32VAC/VDC 5PK CRD |
7,335 |
|
|
AGA | Bulk | Active | Requires Holder | Cartridge, Glass | 30 A | 32 V | 32 V | - | - | - | - | - | - | 0.250" Dia x 0.625" L (6.35mm x 15.88mm) | |
|
0AGA015.VPFUSE GLASS 15A 32VAC/VDC 5PK CRD |
7,778 |
|
|
AGA | Bulk | Active | Requires Holder | Cartridge, Glass | 15 A | 32 V | 32 V | - | - | - | - | - | - | 0.250" Dia x 0.625" L (6.35mm x 15.88mm) | |
|
0AGA005.VPFUSE GLASS 5A 32VAC/VDC 5 PK CRD |
6,885 |
|
|
AGA | Bulk | Active | Requires Holder | Cartridge, Glass | 5 A | 32 V | 32 V | - | - | - | - | - | - | 0.250" Dia x 0.625" L (6.35mm x 15.88mm) | |
|
0AGA003.VPFUSE GLASS 3A 32VAC/VDC 5 PK CRD |
9,091 |
|
|
AGA | Bulk | Active | Requires Holder | Cartridge, Glass | 3 A | 32 V | 32 V | - | - | - | - | - | - | 0.250" Dia x 0.625" L (6.35mm x 15.88mm) |
Kategorieübersicht
Sicherungen Produkte und Auswahlhilfe
Sicherungen werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Sicherungen nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Sicherungen aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.