| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Verpackung/Gehäuse | Serie | Verpackung | Produktstatus | Montageart | Sicherungstyp | Stromstärke (Ampere) | Spannungsstärke - Wechselstrom | Spannungsstärke - Gleichstrom | Reaktionszeit | Ausschaltvermögen bei Nennspannung | Schmelz I²t | Zulassungsstelle | Betriebstemperatur | Farbe | Größe/Abmessung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3AP 200FUSE GLASS 200MA 250VAC 3AB 3AG |
5,260 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 200 mA | 250 V | - | Fast Blow | 200A | 0.014 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 250FUSE GLASS 250MA 250VAC 3AB 3AG |
4,237 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 250 mA | 250 V | - | Fast Blow | 200A | 0.025 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 300FUSE GLASS 300MA 250VAC 3AB 3AG |
3,403 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 300 mA | 250 V | - | Fast Blow | 200A | 0.044 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 375FUSE GLASS 375MA 250VAC 3AB 3AG |
2,307 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 375 mA | 250 V | - | Fast Blow | 200A | 0.07 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 500FUSE GLASS 500MA 250VAC 3AB 3AG |
7,325 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 500 mA | 250 V | - | Fast Blow | 200A | 0.14 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 750FUSE GLASS 750MA 250VAC 3AB 3AG |
3,707 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 750 mA | 250 V | - | Fast Blow | 200A | 0.75 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 1FUSE GLASS 1A 250VAC 3AB 3AG |
2,558 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 1 A | 250 V | - | Fast Blow | 200A | 1.43 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 1.25FUSE GLASS 1.25A 250VAC 3AB 3AG |
7,669 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 1.25 A | 250 V | - | Fast Blow | 200A | 2.45 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 1.6FUSE GLASS 1.6A 250VAC 3AB 3AG |
4,674 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 1.6 A | 250 V | - | Fast Blow | 200A | 4.2 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 2FUSE GLASS 2A 250VAC 3AB 3AG |
6,361 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 2 A | 250 V | - | Fast Blow | 200A | 7.2 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 2.5FUSE GLASS 2.5A 250VAC 3AB 3AG |
7,783 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 2.5 A | 250 V | - | Fast Blow | 200A | 12.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 3FUSE GLASS 3A 250VAC 3AB 3AG |
9,833 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 3 A | 250 V | - | Fast Blow | 200A | 21.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 3.5FUSE GLASS 3.5A 250VAC 3AB 3AG |
7,815 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 3.5 A | 250 V | - | Fast Blow | 200A | 28.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 4FUSE GLASS 4A 250VAC 3AB 3AG |
7,577 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 4 A | 250 V | - | Fast Blow | 200A | 36.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 5FUSE GLASS 5A 250VAC 3AB 3AG |
4,443 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 5 A | 250 V | - | Fast Blow | 200A | 63.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 6FUSE GLASS 6A 250VAC 3AB 3AG |
5,482 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 6 A | 250 V | - | Fast Blow | 200A | 107.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 7FUSE GLASS 7A 250VAC 3AB 3AG |
4,083 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 7 A | 250 V | - | Fast Blow | 200A | 141.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 8FUSE GLASS 8A 250VAC 3AB 3AG |
9,968 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 8 A | 250 V | - | Fast Blow | 200A | 184.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 10FUSE GLASS 10A 250VAC 3AB 3AG |
3,592 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 10 A | 250 V | - | Fast Blow | 200A | 316.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) | |
|
3AP 12FUSE GLASS 12A 125VAC 3AB 3AG |
2,056 |
|
|
3AP | Bulk | Obsolete | Through Hole | Cartridge, Glass | 12 A | 125 V | - | Fast Blow | 10kA | 501.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) |
Kategorieübersicht
Sicherungen Produkte und Auswahlhilfe
Sicherungen werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Sicherungen nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Sicherungen aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.