Sicherungen
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Verpackung/Gehäuse | Serie | Verpackung | Produktstatus | Montageart | Sicherungstyp | Stromstärke (Ampere) | Spannungsstärke - Wechselstrom | Spannungsstärke - Gleichstrom | Reaktionszeit | Ausschaltvermögen bei Nennspannung | Schmelz I²t | Zulassungsstelle | Betriebstemperatur | Farbe | Größe/Abmessung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
GGM105X20MM FUSE 250V 10A GGM |
5 |
|
|
GGM | Box | Active | Requires Holder | Cartridge, Glass | 10 A | 250 V | - | Fast Blow | - | - | CSA, UL, UR | - | - | 0.197" Dia x 0.787" L (5.00mm x 20.00mm) | |
|
BK/GMC-V-1.5-RFUSE GLASS 1.5A 250VAC 5X20MM |
5,466 |
|
|
GMC | Bulk | Active | Through Hole | Cartridge, Glass | 1.5 A | 250 V | - | Medium Blow | 100A | 5.4 | CSA, KC-MARK, MITI, UL | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/GMC-V-1-RFUSE GLASS 1A 250VAC 5X20MM |
2,750 |
|
|
GMC | Bulk | Active | Through Hole | Cartridge, Glass | 1 A | 250 V | - | Medium Blow | 35A | 1.8 | CSA, KC-MARK, UL | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/GMC-V-3.15-RFUSE GLASS 3.15A 250VAC 5X20MM |
3,351 |
|
|
GMC | Bulk | Active | Through Hole | Cartridge, Glass | 3.15 A | 250 V | - | Medium Blow | 100A | 23.0 | CSA, KC-MARK, MITI, UL | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
AGC-V-25-RFUSE GLASS 25A 32VAC 3AB 3AG |
6,505 |
|
|
AGC | Bulk | Active | Through Hole | Cartridge, Glass | 25 A | 32 V | - | Fast Blow | 1kA | 3875.0 | CSA, UL | -55°C ~ 125°C | - | 0.266" Dia x 1.292" L (6.76mm x 32.82mm) | |
|
AGC-V-2-RFUSE GLASS 2A 250VAC 3AB 3AG |
4,472 |
|
|
AGC | Bulk | Active | Through Hole | Cartridge, Glass | 2 A | 250 V | - | Fast Blow | 100A | 17.52 | CSA, UL | -55°C ~ 125°C | - | 0.266" Dia x 1.292" L (6.76mm x 32.82mm) | |
|
AGC-V-3-RFUSE GLASS 3A 250VAC 3AB 3AG |
8,845 |
|
|
AGC | Bulk | Active | Through Hole | Cartridge, Glass | 3 A | 250 V | - | Fast Blow | 100A | 45.9 | CSA, UL | -55°C ~ 125°C | - | 0.266" Dia x 1.292" L (6.76mm x 32.82mm) | |
|
GDL101-1/4X1/4 FUSE 250V 10A GDL |
5 |
|
|
GDL10 | Box | Active | Requires Holder | Cartridge, Glass | 10 A | 125 V | - | Slow Blow | 10kA | - | CSA, UL, UR | - | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
BK/S500-V-160-RFUSE GLASS 160MA 250VAC 5X20MM |
4,811 |
|
|
S500 | Bulk | Active | Through Hole | Cartridge, Glass | 160 mA | 250 V | - | Fast Blow | 35A | 0.008 | BSI, CCC, CSA, cULus, IMQ, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S500-V-200-RFUSE GLASS 200MA 250VAC 5X20MM |
3,521 |
|
|
S500 | Bulk | Active | Through Hole | Cartridge, Glass | 200 mA | 250 V | - | Fast Blow | 35A | 0.016 | BSI, CCC, CSA, cULus, IMQ, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S500-V-250-RFUSE GLASS 250MA 250VAC 5X20MM |
9,171 |
|
|
S500 | Bulk | Active | Through Hole | Cartridge, Glass | 250 mA | 250 V | - | Fast Blow | 35A | 0.28 | BSI, CCC, CSA, cULus, IMQ, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S500-V-315-RFUSE GLASS 315MA 250VAC 5X20MM |
9,292 |
|
|
S500 | Bulk | Active | Through Hole | Cartridge, Glass | 315 mA | 250 V | - | Fast Blow | 35A | 0.58 | BSI, CCC, CSA, cULus, IMQ, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S506-V-1.25RFUSE GLASS 1.25A 250VAC 5X20MM |
8,947 |
|
|
S506 | Bulk | Active | Through Hole | Cartridge, Glass | 1.25 A | 250 V | - | Slow Blow | 35A | 10.05 | BSI, CCC, CSA, CURUS, IMQ, PSE/JET, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S506-V-3.15RFUSE GLASS 3.15A 250VAC 5X20MM |
6,862 |
|
|
S506 | Bulk | Active | Through Hole | Cartridge, Glass | 3.15 A | 250 V | - | Slow Blow | 35A | 96.4 | BSI, CCC, CSA, CURUS, IMQ, PSE/JET, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S506-V-4-RFUSE GLASS 4A 250VAC 5X20MM |
5,468 |
|
|
S506 | Bulk | Active | Through Hole | Cartridge, Glass | 4 A | 250 V | - | Slow Blow | 40A | 71.8 | BSI, CCC, CSA, CURUS, IMQ, PSE/JET, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S506-V-630-RFUSE GLASS 630MA 250VAC 5X20MM |
4,754 |
|
|
S506 | Bulk | Active | Through Hole | Cartridge, Glass | 630 mA | 250 V | - | Slow Blow | 35A | 1.33 | BSI, CCC, CSA, cULus, IMQ, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/GMA-V-100-RFUSE GLASS 100MA 250VAC 5X20MM |
5,367 |
|
|
GMA | Bulk | Active | Through Hole | Cartridge, Glass | 100 mA | 250 V | - | Fast Blow | 35A | 1.0E-4 | CSA, PSE, UL | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/GMA-V-125-RFUSE GLASS 125MA 250VAC 5X20MM |
2,574 |
|
|
GMA | Bulk | Active | Through Hole | Cartridge, Glass | 125 mA | 250 V | - | Fast Blow | 35A | 0.0024 | CSA, PSE, UL | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/GMA-V-63-RFUSE GLASS 63MA 250VAC 5X20MM |
2,770 |
|
|
GMA | Bulk | Active | Through Hole | Cartridge, Glass | 63 mA | 250 V | - | Fast Blow | 35A | 2.4E-4 | CSA, PSE, UL | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/MDL-V1-2/10RFUSE GLASS 1.2A 250VAC 3AB 3AG |
4,127 |
|
|
MDL | Bulk | Active | Through Hole | Cartridge, Glass | 1.2 A | 250 V | - | Slow Blow | - | - | - | - | - | 0.266" Dia x 1.292" L (6.76mm x 32.82mm) |
Kategorieübersicht
Sicherungen Produkte und Auswahlhilfe
Sicherungen werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Sicherungen nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Sicherungen aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.