Sicherungen
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Verpackung/Gehäuse | Serie | Verpackung | Produktstatus | Montageart | Sicherungstyp | Stromstärke (Ampere) | Spannungsstärke - Wechselstrom | Spannungsstärke - Gleichstrom | Reaktionszeit | Ausschaltvermögen bei Nennspannung | Schmelz I²t | Zulassungsstelle | Betriebstemperatur | Farbe | Größe/Abmessung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0326003.HXPFUSE CERM 3A 250VAC 125VDC 3AB |
84 |
|
|
326 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 3 A | 250 V | 125 V | Slow Blow | 100A AC, 10kA DC | 200.0 | CE, CSA, K-MARK, PSE, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
|
35611250029FUSE CERM 1.25A 440VAC 3AB 3AG |
83 |
|
|
356 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 1.25 A | 440 V | - | Slow Blow | 1kA | 3.1 | CE, cULus | -25°C ~ 70°C | - | 0.248" Dia x 1.260" L (6.30mm x 32.00mm) | |
|
032603.2HXPFUSE CERAMIC 3.2A 250VAC 3AB 3AG |
100 |
|
|
326 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 3.2 A | 250 V | - | Slow Blow | 100A | 214.0 | CE, CSA, K-MARK, PSE, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0326.400HXPFUSE CERM 400MA 250VAC 125VDC |
44 |
|
|
326 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 400 mA | 250 V | 125 V | Slow Blow | 100A AC, 10kA DC | 1.33 | CE, CSA, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0326030.HXPFUSE CERM 30A 250VAC 125VDC 3AB |
100 |
|
|
326 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 30 A | 250 V | 125 V | Slow Blow | 400A AC, 600A DC | 1690.0 | CE, CSA, K-MARK, PSE, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
032601.6HXPFUSE CERM 1.6A 250VAC 125VDC 3AB |
69 |
|
|
326 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 1.6 A | 250 V | 125 V | Slow Blow | 100A AC, 10kA DC | 45.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
|
35612500029FUSE CERAMIC 2.5A 440VAC 3AB 3AG |
85 |
|
|
356 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 2.5 A | 440 V | - | Slow Blow | 1kA | 22.0 | CE, cULus | -25°C ~ 70°C | - | 0.248" Dia x 1.260" L (6.30mm x 32.00mm) | |
|
0473007.MAT1LFUSE BRD MNT 7A 125VAC/VDC AXIAL |
78 |
|
|
PICO® II 473 | Cut Tape (CT) | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 7 A | 125 V | 125 V | Slow Blow | 50A | 105.0 | CSA, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
|
0324007.HXPFUSE CERM 7A 250VAC 125VDC 3AB |
85 |
|
|
324 | Bulk | Active | Through Hole | Cartridge, Ceramic | 7 A | 250 V | 125 V | Fast Blow | 750A AC, 10kA DC | 71.0 | CE, CSA, K-MARK, PSE, UL | -55°C ~ 125°C | - | 0.275" Dia x 1.288" L (6.99mm x 32.72mm) | |
|
0MIN020.HXGLOFUSE AUTO 20A 32VAC 32VDC BLADE |
66 |
|
|
MINI® | Bulk | Active | Requires Holder | Automotive | 20 A | 32 V | 32 V | Fast Blow | - | - | SAE, UL | - | Yellow | 0.429" L x 0.150" W x 0.346" H (10.90mm x 3.80mm x 8.80mm) | |
|
0473003.HAT1LFUSE BRD MNT 3A 125VAC/VDC AXIAL |
128 |
|
|
PICO® II 473 | Cut Tape (CT) | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 3 A | 125 V | 125 V | Slow Blow | 50A | 21.0 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
0MIN025.HXGLOFUSE AUTO 25A 32VAC 32VDC BLADE |
47 |
|
|
MINI® | Bulk | Active | Requires Holder | Automotive | 25 A | 32 V | 32 V | Fast Blow | - | - | SAE, UL | - | Clear | 0.429" L x 0.150" W x 0.346" H (10.90mm x 3.80mm x 8.80mm) | |
|
0312.200HXPFUSE GLASS 200MA 250VAC 3AB 3AG |
58 |
|
|
312 | Bulk | Active | Requires Holder | Cartridge, Glass | 200 mA | 250 V | - | Fast Blow | 35A | 0.0165 | CE, CSA, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
|
0895025.UFUSE AUTO 25A 58VDC AUTO LINK |
38 |
|
|
JCASE® | Bulk | Active | Requires Holder | Automotive | 25 A | - | 58 V | - | 1kA | 680.0 | - | -40°C ~ 125°C | Clear | 0.571" L x 0.472" W x 0.630" H (14.50mm x 12.00mm x 16.00mm) | |
|
BK/SFE-6FUSE GLASS 6A 32VDC |
55 |
|
|
SFE | Bulk | Active | Requires Holder | Cartridge, Glass | 6 A | - | 32 V | Fast Blow | - | - | UL | - | - | 0.250" Dia x 0.748" L (6.35mm x 19.00mm) | |
|
BK/AGX-15FUSE GLASS 15A 250VAC 8AG |
77 |
|
|
AGX | Bulk | Active | Requires Holder | Cartridge, Glass | 15 A | 250 V | - | Fast Blow | 200A | - | cURus | - | - | 0.250" Dia x 1.042" L (6.35mm x 26.47mm) | |
|
0313.100HXPFUSE GLASS 100MA 250VAC 3AB 3AG |
55 |
|
|
313 | Bulk | Active | Requires Holder | Cartridge, Glass | 100 mA | 250 V | - | Slow Blow | 35A | 0.085 | CE, CSA, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
BK/SFE-14FUSE GLASS 14A 32VDC |
96 |
|
|
SFE | Bulk | Active | Requires Holder | Cartridge, Glass | 14 A | - | 32 V | Fast Blow | - | - | UL | - | - | 0.250" Dia x 1.063" L (6.35mm x 27.00mm) | |
|
BK/GMA-V-5-RFUSE GLASS 5A 125VAC 5X20MM |
63 |
|
|
GMA | Bulk | Active | Through Hole | Cartridge, Glass | 5 A | 125 V | - | Fast Blow | 10kA | 29.0 | CSA, PSE, UL | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/AGC-14-RFUSE GLASS 14A 32VAC 3AB 3AG |
77 |
|
|
AGC | Bulk | Active | Requires Holder | Cartridge, Glass | 14 A | 32 V | - | Fast Blow | 1kA | 776.16 | CSA, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) |
Kategorieübersicht
Sicherungen Produkte und Auswahlhilfe
Sicherungen werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Sicherungen nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Sicherungen aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.