| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Verpackung/Gehäuse | Serie | Verpackung | Produktstatus | Montageart | Sicherungstyp | Stromstärke (Ampere) | Spannungsstärke - Wechselstrom | Spannungsstärke - Gleichstrom | Reaktionszeit | Ausschaltvermögen bei Nennspannung | Schmelz I²t | Zulassungsstelle | Betriebstemperatur | Farbe | Größe/Abmessung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BK1/TDC11-250MAFUSE GLASS 250MA 1KVAC 1K BAG |
5,442 |
|
|
TDC | - | Active | Requires Holder | Cartridge, Glass | 250 mA | 1 kV | - | Slow Blow | 2.5A | - | - | - | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
BK1/TDC11-2AFUSE GLASS 2A 250VAC 3AB 1000BAG |
7,905 |
|
|
TDC | - | Active | Requires Holder | Cartridge, Glass | 2 A | 250 V | - | Slow Blow | 20A | - | - | - | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
BK1/TDC11-500MAFUSE GLASS 500MA 750VAC 1K BAG |
5,198 |
|
|
TDC | - | Active | Requires Holder | Cartridge, Glass | 500 mA | 750 V | - | Slow Blow | 5A | - | - | - | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
BK1/TDC11-50MAFUSE GLASS 50MA 1KVAC 3AB 1K BAG |
8,277 |
|
|
TDC | - | Active | Requires Holder | Cartridge, Glass | 50 mA | 1 kV | - | Slow Blow | 500mA | - | - | - | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
BK1/TDC11-5AFUSE GLASS 5A 250VAC 3AB 1000BAG |
7,791 |
|
|
TDC | - | Active | Requires Holder | Cartridge, Glass | 5 A | 250 V | - | Slow Blow | 50A | - | - | - | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
BK1-S506-32-R-DBFUSE GLASS 32MA 250VAC 1000BAG |
4,123 |
|
|
S506 | - | Active | Requires Holder | Cartridge, Glass | 32 mA | 250 V | - | Slow Blow | 35A | 0.0051 | BSI, CCC, IMQ, SEMKO, UR, VDE | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMD-2.5AFUSE GLASS 2.5A 250VAC 5X20MM |
3,243 |
|
|
GMD | - | Obsolete | Requires Holder | Cartridge, Glass | 2.5 A | 250 V | - | Slow Blow | 100A | 94.0 | CSA, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
TR/MDA-V-15FUSE CERAMIC 15A 250VAC 3AB 3AG |
9,845 |
|
|
MDA | Tape & Reel (TR) | Obsolete | Through Hole | Cartridge, Ceramic | 15 A | 250 V | - | Slow Blow | 750A | 206.2 | CSA, UL | - | Black | 0.266" Dia x 1.292" L (6.76mm x 32.82mm) | |
|
GMA-100MAFUSE GLASS 100MA 250VAC 5X20MM |
5,498 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 100 mA | 250 V | - | Fast Blow | 35A | 1.0E-4 | CSA, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMA-125MAFUSE GLASS 125MA 250VAC 5X20MM |
3,956 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 125 mA | 250 V | - | Fast Blow | 35A | 0.0024 | CSA, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMA-15AFUSE GLASS 15A 125VAC 5X20MM |
9,285 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 15 A | 125 V | - | Fast Blow | 150A | 950.0 | PSE, UR | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMA-1AFUSE GLASS 1A 250VAC 5X20MM |
8,556 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 1 A | 250 V | - | Fast Blow | 35A | 0.48 | CSA, PSE, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMA-200MAFUSE GLASS 200MA 250VAC 5X20MM |
4,929 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 200 mA | 250 V | - | Fast Blow | 35A | 0.001 | CSA, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMA-250MAFUSE GLASS 250MA 250VAC 5X20MM |
4,974 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 250 mA | 250 V | - | Fast Blow | 35A | 0.018 | CSA, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMA-3AFUSE GLASS 3A 250VAC 5X20MM |
8,086 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 3 A | 250 V | - | Fast Blow | 100A | 8.8 | CSA, PSE, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMA-500MAFUSE GLASS 500MA 250VAC 5X20MM |
7,506 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 500 mA | 250 V | - | Fast Blow | 35A | 0.15 | CSA, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMA-63MAFUSE GLASS 63MA 250VAC 5X20MM |
3,273 |
|
|
GMA | - | Obsolete | Requires Holder | Cartridge, Glass | 63 mA | 250 V | - | Fast Blow | 35A | 2.4E-4 | CSA, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMC-3AFUSE GLASS 3A 250VAC 5X20MM |
7,848 |
|
|
GMC | - | Obsolete | Requires Holder | Cartridge, Glass | 3 A | 250 V | - | Medium Blow | 100A | 19.0 | CCC, CSA, MITI, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMC-500MAFUSE GLASS 500MA 250VAC 5X20MM |
3,421 |
|
|
GMC | - | Obsolete | Requires Holder | Cartridge, Glass | 500 mA | 250 V | - | Medium Blow | 35A | 0.41 | CCC, CSA, MITI, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
GMC-6AFUSE GLASS 6A 250VAC 5X20MM |
7,563 |
|
|
GMC | - | Obsolete | Requires Holder | Cartridge, Glass | 6 A | 250 V | - | Medium Blow | 10kA | 88.0 | CCC, CSA, MITI, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) |
Kategorieübersicht
Sicherungen Produkte und Auswahlhilfe
Sicherungen werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Sicherungen nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Sicherungen aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.