Sicherungen
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Verpackung/Gehäuse | Serie | Verpackung | Produktstatus | Montageart | Sicherungstyp | Stromstärke (Ampere) | Spannungsstärke - Wechselstrom | Spannungsstärke - Gleichstrom | Reaktionszeit | Ausschaltvermögen bei Nennspannung | Schmelz I²t | Zulassungsstelle | Betriebstemperatur | Farbe | Größe/Abmessung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BK/S505-V-500-RFUSE CERAMIC 500MA 250VAC 5X20MM |
8,308 |
|
|
S505 | Bulk | Obsolete | Through Hole | Cartridge, Ceramic | 500 mA | 250 V | - | Slow Blow | 1.5kA | 0.188 | BSI, CCC/CQC, CSA, cULus, IMQ, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S505-V-5-RFUSE CERAMIC 5A 250VAC 5X20MM |
7,943 |
|
|
S505 | Bulk | Obsolete | Through Hole | Cartridge, Ceramic | 5 A | 250 V | - | Slow Blow | 1.5kA | 71.3 | BSI, CCC/CQC, CSA, cULus, IMQ, KC, PSE/JET, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK/S505-V-800-RFUSE CERAMIC 800MA 250VAC 5X20MM |
4,794 |
|
|
S505 | Bulk | Obsolete | Through Hole | Cartridge, Ceramic | 800 mA | 250 V | - | Slow Blow | 1.5kA | 0.632 | BSI, CCC/CQC, CSA, cULus, IMQ, SEMKO, VDE | - | - | 0.218" Dia x 0.831" L (5.54mm x 21.10mm) | |
|
BK1/MCRW12AFUSE BOARD MOUNT 12A 125VAC/VDC |
6,141 |
|
|
Microtron® MCRW | Bulk | Obsolete | Through Hole | Board Mount (Cartridge Style Excluded) | 12 A | 125 V | 125 V | Fast Blow | 50A AC, 300A DC | 35.0 | CSA, UL | - | - | 0.125" Dia x 0.280" L (3.18mm x 7.10mm) | |
|
BK1/MCRW15AFUSE BOARD MOUNT 15A 125VAC/VDC |
6,322 |
|
|
Microtron® MCRW | Bulk | Obsolete | Through Hole | Board Mount (Cartridge Style Excluded) | 15 A | 125 V | 125 V | Fast Blow | 50A AC, 300A DC | 63.0 | CSA, UL | - | - | 0.125" Dia x 0.280" L (3.18mm x 7.10mm) | |
|
BK1/MCRW200MAFUSE BRD MT 200MA 125VAC/VDC AXL |
3,189 |
|
|
Microtron® MCRW | Bulk | Obsolete | Through Hole | Board Mount (Cartridge Style Excluded) | 200 mA | 125 V | 125 V | Fast Blow | 50A AC, 300A DC | 0.002 | CSA, UL | - | - | 0.125" Dia x 0.280" L (3.18mm x 7.10mm) | |
|
|
GMD-200-RFUSE GLASS 200MA 250VAC 5X20MM |
2,980 |
|
|
GMD | Bulk | Active | Requires Holder | Cartridge, Glass | 200 mA | 250 V | - | Slow Blow | 35A | 0.2 | CSA, UL | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
KTQ-2FUSE CERAMIC 2A 600VAC |
3,334 |
|
|
KTQ | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 2 A | 600 V | - | Fast Blow | 10kA | - | UL | - | - | 0.406" Dia x 1.378" L (10.30mm x 35.00mm) | |
|
KTQ-3FUSE CERAMIC 3A 600VAC |
5,732 |
|
|
KTQ | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 3 A | 600 V | - | Fast Blow | 10kA | - | UL | - | - | 0.406" Dia x 1.378" L (10.30mm x 35.00mm) | |
|
KTQ-4FUSE CERAMIC 4A 600VAC |
8,655 |
|
|
KTQ | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 4 A | 600 V | - | Fast Blow | 10kA | - | UL | - | - | 0.406" Dia x 1.378" L (10.30mm x 35.00mm) | |
|
KTQ-5FUSE CERAMIC 5A 600VAC |
8,081 |
|
|
KTQ | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 5 A | 600 V | - | Fast Blow | 10kA | - | UL | - | - | 0.406" Dia x 1.378" L (10.30mm x 35.00mm) | |
|
KTQ-6FUSE CERAMIC 6A 600VAC |
4,441 |
|
|
KTQ | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 6 A | 600 V | - | Fast Blow | 10kA | - | UL | - | - | 0.406" Dia x 1.378" L (10.30mm x 35.00mm) | |
|
04611.25EERFUSE BRD MNT 600VAC 80VDC 2SMD |
3,961 |
|
|
Telelink® 461E | Tape & Reel (TR) | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 1.25 A | 600 V | 80 V | Slow Blow | 60A AC, 100A DC | 16.5 | CSA, UL | -55°C ~ 125°C | - | 0.398" L x 0.123" W x 0.123" H (10.10mm x 3.12mm x 3.12mm) | |
|
|
0316.500NAT1FUSE BRD MT 500MA 125VAC/VDC AXL |
4,482 |
|
|
PICO® II 316 | Tape & Box (TB) | Obsolete | Through Hole | Board Mount (Cartridge Style Excluded) | 500 mA | 125 V | 125 V | Fast Blow | 50A | 0.0598 | CCC | -55°C ~ 125°C | - | 0.110" Dia x 0.280" L (2.80mm x 7.11mm) | |
|
|
0316002.NAT1FUSE BRD MNT 2A 125VAC/VDC AXIAL |
8,529 |
|
|
PICO® II 316 | Tape & Box (TB) | Obsolete | Through Hole | Board Mount (Cartridge Style Excluded) | 2 A | 125 V | 125 V | Fast Blow | 50A | 0.405 | CCC | -55°C ~ 125°C | - | 0.110" Dia x 0.280" L (2.80mm x 7.11mm) | |
|
0674.100MXEPFUSE CERAMIC 100MA 250VAC AXIAL |
3,200 |
|
|
674 | Bulk | Obsolete | Through Hole | Cartridge, Ceramic | 100 mA | 250 V | - | Fast Blow | 50A | 0.00192 | CSA, UL | - | - | 0.154" Dia x 0.433" L (3.90mm x 11.00mm) | |
|
0674.125MXEPFUSE CERAMIC 125MA 250VAC AXIAL |
4,413 |
|
|
674 | Bulk | Obsolete | Through Hole | Cartridge, Ceramic | 125 mA | 250 V | - | Fast Blow | 50A | 0.00299 | CSA, UL | - | - | 0.154" Dia x 0.433" L (3.90mm x 11.00mm) | |
|
0674.200MXEPFUSE CERAMIC 200MA 250VAC AXIAL |
2,463 |
|
|
674 | Bulk | Obsolete | Through Hole | Cartridge, Ceramic | 200 mA | 250 V | - | Fast Blow | 50A | 0.0114 | CSA, UL | - | - | 0.154" Dia x 0.433" L (3.90mm x 11.00mm) | |
|
0674.250MXEPFUSE CERAMIC 250MA 250VAC AXIAL |
5,079 |
|
|
674 | Bulk | Obsolete | Through Hole | Cartridge, Ceramic | 250 mA | 250 V | - | Fast Blow | 50A | 0.0225 | CSA, UL | - | - | 0.154" Dia x 0.433" L (3.90mm x 11.00mm) | |
|
0674.300MXEPFUSE CERAMIC 300MA 250VAC AXIAL |
8,008 |
|
|
674 | Bulk | Obsolete | Through Hole | Cartridge, Ceramic | 300 mA | 250 V | - | Fast Blow | 50A | 0.0295 | CSA, UL | - | - | 0.154" Dia x 0.433" L (3.90mm x 11.00mm) |
Kategorieübersicht
Sicherungen Produkte und Auswahlhilfe
Sicherungen werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Sicherungen nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Sicherungen aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.
