| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Verpackung/Gehäuse | Serie | Verpackung | Produktstatus | Montageart | Sicherungstyp | Stromstärke (Ampere) | Spannungsstärke - Wechselstrom | Spannungsstärke - Gleichstrom | Reaktionszeit | Ausschaltvermögen bei Nennspannung | Schmelz I²t | Zulassungsstelle | Betriebstemperatur | Farbe | Größe/Abmessung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
GSA 125-RFUSE CERM 125MA 250VAC 3AB 3AG |
8,564 |
|
|
GSA | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 125 mA | 250 V | - | Slow Blow | 35A | 0.323 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
2JS 125-RFUSE GLASS 125MA 350VAC 140VDC |
7,526 |
|
|
2JS | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 125 mA | 350 V | 140 V | Slow Blow | 100A AC, 150A DC | 0.107 | CSA, cURus | -55°C ~ 125°C | - | 0.201" Dia x 0.543" L (5.10mm x 13.80mm) | |
|
|
2JQ 250-RFUSE GLASS 250MA 350VAC 140VDC |
9,939 |
|
|
2JQ | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 250 mA | 350 V | 140 V | Fast Blow | 100A AC, 150A DC | 0.014 | CE, CSA, cURus | -55°C ~ 125°C | - | 0.201" Dia x 0.543" L (5.10mm x 13.80mm) | |
|
|
2JQ 125-RFUSE GLASS 125MA 350VAC 140VDC |
9,116 |
|
|
2JQ | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 125 mA | 350 V | 140 V | Fast Blow | 100A AC, 150A DC | 0.0019 | CE, CSA, cURus | -55°C ~ 125°C | - | 0.201" Dia x 0.543" L (5.10mm x 13.80mm) | |
|
2JS 250-RFUSE GLASS 250MA 350VAC 140VDC |
5,765 |
|
|
2JS | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 250 mA | 350 V | 140 V | Slow Blow | 100A AC, 150A DC | 0.41 | CE, CSA, cURus | -55°C ~ 125°C | - | 0.201" Dia x 0.543" L (5.10mm x 13.80mm) | |
|
|
GSA 200-RFUSE CERM 200MA 250VAC 3AB 3AG |
7,478 |
|
|
GSA | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 200 mA | 250 V | - | Slow Blow | 35A | 0.773 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
|
GSA 100-RFUSE CERM 100MA 250VAC 3AB 3AG |
2,095 |
|
|
GSA | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 100 mA | 250 V | - | Slow Blow | 35A | 0.209 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | |
|
5MT 200-RFUSE GLASS 200MA 250VAC 5X20MM |
2,041 |
|
|
5MT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 200 mA | 250 V | - | Medium Blow | 35A | 0.11 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5MT 160-RFUSE GLASS 160MA 250VAC 5X20MM |
9,920 |
|
|
5MT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 160 mA | 250 V | - | Medium Blow | 35A | 0.06 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5MT 1.6-RFUSE GLASS 1.6A 250VAC 5X20MM |
9,478 |
|
|
5MT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 1.6 A | 250 V | - | Medium Blow | 100A | 12.0 | CE, CSA, cULus, PSE | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5MT 1.25-RFUSE GLASS 1.25A 250VAC 5X20MM |
7,630 |
|
|
5MT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 1.25 A | 250 V | - | Medium Blow | 100A | 7.2 | CE, CSA, cULus, PSE | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5MT 125-RFUSE GLASS 125MA 250VAC 5X20MM |
7,715 |
|
|
5MT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 125 mA | 250 V | - | Medium Blow | 35A | 0.04 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5MT 100-RFUSE GLASS 100MA 250VAC 5X20MM |
5,688 |
|
|
5MT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 100 mA | 250 V | - | Medium Blow | 35A | 0.02 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5MT 800-RFUSE GLASS 800MA 250VAC 5X20MM |
3,294 |
|
|
5MT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 800 mA | 250 V | - | Medium Blow | 35A | 3.8 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
|
5TT 160-RFUSE GLASS 160MA 250VAC 5X20MM |
5,406 |
|
|
5TT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 160 mA | 250 V | - | Slow Blow | 100A | 0.314 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5VT 1.25-RFUSE GLASS 1.25A 250VAC 5X20MM |
7,148 |
|
|
5VT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 1.25 A | 250 V | - | Slow Blow | 35A | 42.0 | CCC, CE, CSA, cULus, SEMKO, VDE | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5VT 1-RFUSE GLASS 1A 250VAC 5X20MM |
9,523 |
|
|
5VT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 1 A | 250 V | - | Slow Blow | 35A | 28.0 | CCC, CE, CSA, cULus, SEMKO, VDE | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5VT 2-RFUSE GLASS 2A 250VAC 5X20MM |
8,172 |
|
|
5VT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 2 A | 250 V | - | Slow Blow | 35A | 92.0 | CCC, CE, CSA, cULus, SEMKO, VDE | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
5VT 1.6-RFUSE GLASS 1.6A 250VAC 5X20MM |
2,291 |
|
|
5VT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 1.6 A | 250 V | - | Slow Blow | 35A | 62.0 | CCC, CE, CSA, cULus, SEMKO, VDE | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) | |
|
|
5TT 100-RFUSE GLASS 100MA 250VAC 5X20MM |
8,941 |
|
|
5TT | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 100 mA | 250 V | - | Slow Blow | 100A | 0.137 | CE, CSA, cULus | -55°C ~ 125°C | - | 0.201" Dia x 0.787" L (5.10mm x 20.00mm) |
Kategorieübersicht
Sicherungen Produkte und Auswahlhilfe
Sicherungen werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Sicherungen nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Sicherungen aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.