| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung | Produktstatus | Verpackung | ProdictStatis | Typ | Ausgabetyp | Ausgangskonfiguration | Strom | Mindestdichte Flüssigkeit | Schalterbetätigungspegel | Montageart | Material - Gehäuse & Prisma | Betriebstemperatur | Spannungsstärke |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
80649-000SENSOR LEVEL SWITCH SINGLE FLOAT |
51 |
|
|
- | Box | Active | Liquid | Switch (Single Float) | SPST-NO | 1 A | - | - | Panel Mount, Male 1/2" (12.7mm) NPT | Polypropylene (PP) | -30°C ~ 110°C | 100V | ||
|
RSF84Y100RSENSOR LEVEL SWITCH SINGLE FLOAT |
98 |
|
|
RSF80 | Bag | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 600 mA | 0.85 | 0.787" (20mm) | Male 1/2" (12.7mm) NPT | Polypropylene (PP) | -20°C ~ 100°C | 120VDC, 240VAC | ||
|
RSF43Y100RFSENSOR LEVEL SWITCH SINGLE FLOAT |
22 |
|
|
RSF40 | Bag | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 600 mA | 0.85 | 0.787" (20mm) | Panel Mount, M16x2 Thread | Nylon | -20°C ~ 75°C | 120VDC, 240VAC | ||
|
PLS-045A-3VAISENSOR LEVEL SWITCH |
98 |
|
|
- | Bulk | Active | Liquid, Powder | Switch | SPST-NO | 1 A | - | 1.831" (46.5mm) | Panel Mount, M10 Thread | Stainless Steel | -40°C ~ 125°C | 200V | ||
|
RSF158YFPSENSOR LEVEL SWITCH SINGLE FLOAT |
6 |
|
|
RSF150 | Bulk | Active | Liquid | Switch (Single Float) | SPST-NO | 600 mA | 0.65 | 1.024" (26mm) | Panel Mount, M16x2 Thread | Polypropylene (PP) | -20°C ~ 100°C | 120VDC, 240VAC | ||
|
RSF48Y100RFSENSOR LEVEL SWITCH SINGLE FLOAT |
35 |
|
|
RSF40 | Bulk | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 600 mA | 0.8 | 0.787" (20mm) | Panel Mount, M16x2 Thread | Polypropylene (PP) | -20°C ~ 100°C | 120VDC, 240VAC | ||
|
RSF44Y100RFSENSOR LEVEL SWITCH SINGLE FLOAT |
13 |
|
|
RSF40 | Bag | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 600 mA | 0.85 | 0.787" (20mm) | Panel Mount, M16x2 Thread | Polypropylene (PP) | -20°C ~ 100°C | 120VDC, 240VAC | ||
|
LLC200D3LSHSENSOR LEVEL DIGITAL |
36 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -25°C ~ 80°C | 4.5V ~ 15.4V | ||
|
LLC700D3SHSENSOR LEVEL DIGITAL |
29 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -25°C ~ 80°C | 4.5V ~ 15.4V | ||
|
LLC700D3LSHSENSOR LEVEL DIGITAL |
16 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -25°C ~ 80°C | 4.5V ~ 15.4V | ||
|
464SENSOR LEVEL RESISTIVE |
12 |
|
|
eTape™ | Bulk | Active | Liquid, Powder | Resistive | - | - | - | - | Adhesive | Polyethylene Terephthalate (PET) | -9°C ~ 60°C | 10V | ||
|
LLC510D3SENSOR LEVEL DIGITAL |
36 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 4.5V ~ 15.4V | ||
|
LLC510D3LSENSOR LEVEL DIGITAL |
12 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 4.5V ~ 15.4V | ||
|
RSF47Y100GFSENSOR LEVEL SWITCH SINGLE FLOAT |
88 |
|
|
RSF40 | Bulk | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 600 mA | 0.85 | 1.654" (42mm) | Panel Mount, M16x2 Thread | Polyvinylidene Fluoride (PVDF) | -10°C ~ 105°C | 300VAC, 300VDC | ||
|
OLS210D3SHSENSOR LEVEL PUSH-PULL |
10 |
|
|
OLS2 | Bulk | Active | Liquid | Push-Pull | High-Dry | 2.5 mA | - | - | Threaded | Polysulfone | -40°C ~ 125°C | 5V ~ 15V | ||
|
RSF66A25B100SENSOR LEVEL SWITCH SINGLE FLOAT |
10 |
|
|
RSF66 | Bulk | Active | Liquid | Switch (2) (Single Float) | SPST-NC/NO | 600 mA | 0.85 | 1.181", 3.937" (30mm, 100mm) | Panel Mount, M16x2 Thread | Polypropylene Sulphide (PPS) | -10°C ~ 85°C | 120VDC, 240VAC | ||
|
LLC710D3L24-3SENSOR LEVEL SWITCH |
18 |
|
|
- | Bulk | Active | Liquid | Switch | NPN | 7.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 8V ~ 30V | ||
|
LLC210D3L24-5SENSOR LEVEL DIGITAL |
9 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 7.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 8V ~ 30V | ||
|
LLC610D3L24-5SENSOR LEVEL DIGITAL |
9 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 7.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 8V ~ 30V | ||
|
RSF166A25B175SENSOR LEVEL SWITCH SINGLE FLOAT |
7 |
|
|
RSF166 | Box | Active | Liquid | Switch (2) (Single Float) | SPST-NC/NO | 600 mA | 0.85 | 1.181", 6.890" (30mm, 175mm) | Panel Mount, M16x2 Thread | Polyphenylene Sulphide (PPS) | -10°C ~ 85°C | 120VDC, 240VAC |
Kategorieübersicht
Schwimmer-, Füllstandssensoren Produkte und Auswahlhilfe
Schwimmer-, Füllstandssensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Schwimmer-, Füllstandssensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Schwimmer-, Füllstandssensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.