Schwimmer-, Füllstandssensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung | Produktstatus | Verpackung | ProdictStatis | Typ | Ausgabetyp | Ausgangskonfiguration | Strom | Mindestdichte Flüssigkeit | Schalterbetätigungspegel | Montageart | Material - Gehäuse & Prisma | Betriebstemperatur | Spannungsstärke |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RSF46H050TGSENSOR LEVEL SWITCH SINGLE FLOAT |
5 |
|
|
RSF40 | Bulk | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 1 A | 0.85 | 0.945" (24mm) | Panel Mount, M16x2 Thread | Polyphenylene Sulphide (PPS) | -10°C ~ 120°C | 300VAC, 300VDC | ||
|
LLF48HFPSENSOR LEVEL SWITCH SINGLE FLOAT |
0 |
|
|
LLF40 | Bag | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 1 A | 0.7 | 0.394" (10mm) | Panel Mount, M12 Thread | Polypropylene (PP) | -20°C ~ 100°C | 300V | ||
|
LLF43H100RFSENSOR LEVEL SWITCH SINGLE FLOAT |
0 |
|
|
LLF40 | Bag | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 1 A | 0.7 | 0.394" (10mm) | Male 1" (25.4mm) NPT | Nylon | -20°C ~ 75°C | 300V | ||
|
LLC310D3SENSOR LEVEL DIGITAL |
3 |
|
|
Optomax Digital | Bulk | Active | Liquid | Digital | - | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 4.5V ~ 15.4V | ||
|
LLC310D3LSENSOR LEVEL DIGITAL |
3 |
|
|
Optomax Digital | Bulk | Active | Liquid | Digital | - | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 4.5V ~ 15.4V | ||
|
LLC300D3LSENSOR LEVEL DIGITAL |
2 |
|
|
Optomax Digital | Bulk | Active | Liquid | Digital | - | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -25°C ~ 80°C | 4.5V ~ 15.4V | ||
|
RSF87Y100GSENSOR LEVEL SWITCH SINGLE FLOAT |
2 |
|
|
RSF80 | Bulk | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 600 mA | 0.85 | 0.354" (9mm) | Male 1/2" (12.7mm) NPT | Polyvinylidene Fluoride (PVDF) | -10°C ~ 105°C | 300VAC, 300VDC | ||
|
LLC710D3LSHSENSOR LEVEL DIGITAL |
0 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 2.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 4.5V ~ 15.4V | ||
|
OLS710D3LSHSENSOR LEVEL OPEN COLLECTOR |
0 |
|
|
OLS7 | Bulk | Active | Liquid | Open Collector | Low-Dry | 2.5 mA | - | - | 1/4" NPT and 3/8" Conduit | Polysulfone | -40°C ~ 125°C | 5V ~ 15V | ||
|
OLS710D3SHSENSOR LEVEL OPEN COLLECTOR |
0 |
|
|
OLS7 | Bulk | Active | Liquid | Open Collector | High-Dry | 2.5 mA | - | - | 1/4" NPT and 3/8" Conduit | Polysulfone | -40°C ~ 125°C | 5V ~ 15V | ||
|
LLF47YGPSENSOR LEVEL SWITCH SINGLE FLOAT |
0 |
|
|
LLF40 | Bag | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 600 mA | 0.7 | 0.394" (10mm) | Panel Mount, M12 Thread | Polyvinylidene Fluoride (PVDF) | -10°C ~ 105°C | 120V | ||
|
LLC610D324-005SENSOR LEVEL DIGITAL |
0 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 7.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 8V ~ 30V | ||
|
LLC710D324-5SENSOR LEVEL DIGITAL |
0 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 7.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 8V ~ 30V | ||
|
RSF166A25B75SENSOR LEVEL SWITCH SINGLE FLOAT |
1 |
|
|
RSF166 | Box | Active | Liquid | Switch (2) (Single Float) | SPST-NC/NO | 600 mA | 0.85 | 1.181", 2.953" (30mm, 75mm) | Panel Mount, M16x2 Thread | Polyphenylene Sulphide (PPS) | -10°C ~ 85°C | 120VDC, 240VAC | ||
|
RSF66B50B100PSENSOR LEVEL SWITCH DUAL FLOAT |
0 |
|
|
RSF66 | Bulk | Active | Liquid | Switch (2) (Dual Float) | SPST-NC/NO, SPST-NC/NO | 600 mA | 0.85 | 1.969", 3.937" (50mm, 100mm) | Panel Mount, M16x2 Thread | Polyphenylene Sulphide (PPS) | -10°C ~ 85°C | 120VDC, 240VAC | ||
|
LLF47H100GGSENSOR LEVEL SWITCH SINGLE FLOAT |
0 |
|
|
LLF40 | Bag | Active | Liquid | Switch (Single Float) | SPST-NC/NO | 1 A | 0.7 | 0.394" (10mm) | Male 1" (25.4mm) NPT | Polyvinylidene Fluoride (PVDF) | -10°C ~ 105°C | 300V | ||
|
LLC710D324-4C3SENSOR LEVEL DIGITAL |
1 |
|
|
Optomax Industrial | Bulk | Active | Liquid | Digital | PNP | 7.5 mA | - | - | Threaded | Polysulfone (PES) | -40°C ~ 125°C | 8V ~ 30V | ||
|
LLG610D324-5SENSOR LEVEL DIGITAL |
0 |
|
|
Optomax | Bulk | Active | Liquid | Digital | Push-Pull | 7.5 mA | - | - | Threaded | Stainless Steel | -40°C ~ 125°C | 8V ~ 30V | ||
|
LLG210D3L24-5SENSOR LEVEL SWITCH |
1 |
|
|
- | Bulk | Active | Liquid | Switch | Push-Pull | 7.5 mA | - | - | Threaded | Stainless Steel | -40°C ~ 125°C | 8V ~ 30V | ||
|
LLG610D3L24-5SENSOR LEVEL SWITCH |
1 |
|
|
- | Bulk | Active | Liquid | Switch | Push-Pull | 7.5 mA | - | - | Threaded | Stainless Steel | -40°C ~ 125°C | 8V ~ 30V |
Kategorieübersicht
Schwimmer-, Füllstandssensoren Produkte und Auswahlhilfe
Schwimmer-, Füllstandssensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Schwimmer-, Füllstandssensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Schwimmer-, Füllstandssensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.