Schwimmer-, Füllstandssensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung | Produktstatus | Verpackung | ProdictStatis | Typ | Ausgabetyp | Ausgangskonfiguration | Strom | Mindestdichte Flüssigkeit | Schalterbetätigungspegel | Montageart | Material - Gehäuse & Prisma | Betriebstemperatur | Spannungsstärke |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
59630-4-T-02-DSENSOR LEVEL SWITCH SINGLE FLOAT |
0 |
|
|
59630 | Box | Active | Liquid | Switch (Single Float) | SPST-NC | 500 mA | - | 0.2" (5.08 mm) | Panel Mount, M8 Thread | - | -40°C ~ 105°C | 200VDC | ||
|
59630-4-T-03-FSENSOR LEVEL SWITCH SINGLE FLOAT |
0 |
|
|
59630 | Box | Active | Liquid | Switch (Single Float) | SPST-NC | 500 mA | - | 0.2" (5.08 mm) | Panel Mount, M8 Thread | - | -40°C ~ 105°C | 200VDC | ||
|
59630-4-T-05-DSENSOR LEVEL SWITCH SINGLE FLOAT |
0 |
|
|
59630 | Box | Active | Liquid | Switch (Single Float) | SPST-NC | 500 mA | - | 0.2" (5.08 mm) | Panel Mount, M8 Thread | - | -40°C ~ 105°C | 200VDC | ||
|
|
ILLS-G0100-5-003SENSOR LEVEL ANALOG |
0 |
|
|
ILLS | Bag | Obsolete | Liquid | Analog (Diaphragm) | 4mA ~ 20mA | - | - | - | Cable Mount | 303 Stainless Steel, 316 Stainless Steel | -20°C ~ 60°C | 9V ~ 32V | ||
|
|
ILLS-G0250-5-005SENSOR LEVEL ANALOG |
0 |
|
|
ILLS | Bag | Obsolete | Liquid | Analog (Diaphragm) | 4mA ~ 20mA | - | - | - | Cable Mount | 303 Stainless Steel, 316 Stainless Steel | -20°C ~ 60°C | 9V ~ 32V | ||
|
LS03/DL-1A85-PP-500WSENSOR LEVEL SWITCH SINGLE FLOAT |
0 |
|
|
LS03 | Bulk | Active | Liquid | Switch (Single Float) | SPST-NO | 1 A | - | - | Panel Mount, M16x2 Thread | Polypropylene (PP) | -20°C ~ 80°C | 400V | ||
|
CTANK-A510SENSOR LEVEL CELLULAR |
0 |
|
|
Digi Connect® | Box | Obsolete | Liquid | Cellular | 3G/2G | - | - | - | Male 1" (25.4mm) NPT | Polybutylene Terephthalate (PBT) | -30°C ~ 65°C | 7.2V | ||
|
CTANK-A511SENSOR LEVEL CELLULAR |
0 |
|
|
Digi Connect® | Box | Obsolete | Liquid | Cellular | 3G/2G | - | - | - | Male 1" (25.4mm) NPT | Polybutylene Terephthalate (PBT) | -30°C ~ 65°C | 7.2V | ||
|
CTANK-A621SENSOR LEVEL CELLULAR |
0 |
|
|
Digi Connect® | Box | Obsolete | Liquid | Cellular | 3G/2G | - | - | - | Male 1" (25.4mm) NPT | Polybutylene Terephthalate (PBT) | -30°C ~ 65°C | 7.2V | ||
|
943-F4V-2D-1C0-180SENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943F4V2D1C0180ESENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943F4V2D1C0330ESENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943F4V2D1D0180ESENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943F4Y2D1C0180ESENSOR LEVEL |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943F4Y2D1C0300ESENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943F4Y2D1C0330ESENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943F4Y2D1D0330ESENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943-T4Y-2D001-130ESENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943T4Y2D1D0130ESENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | ||
|
943-T4Y-2D-1D0-200SENSOR LEVEL ULTRASONIC |
0 |
|
|
* | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Schwimmer-, Füllstandssensoren Produkte und Auswahlhilfe
Schwimmer-, Füllstandssensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Schwimmer-, Füllstandssensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Schwimmer-, Füllstandssensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.