Feste Induktoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Typ | Material - Kern | Induktivität | Toleranz | Stromstärke (Ampere) | Strom – Sättigung (Isat) | Abschirmung | Gleichstromwiderstand (DCR) | Q @ Freq | Frequenz - Eigenresonanz | Bewertungen | Betriebstemperatur | Induktivitätsfrequenz – Test | Funktionen | Montageart | Lieferant Gerätepaket | Größe/Abmessung | Höhe - Sitz (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AISM-1812H-180M-TFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Obsolete | Wirewound | - | 18 µH | ±20% | 400 mA | - | Shielded | 800mOhm Max | 10 @ 2.52MHz | 19MHz | - | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-151MFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Obsolete | Wirewound | - | 150 µH | ±20% | 140 mA | - | Shielded | 6.5Ohm Max | 20 @ 796kHz | 7MHz | - | -40°C ~ 125°C | 796 kHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-100KINDUCTOR MOLDED WOUND SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Active | Wirewound | - | 10 µH | ±10% | 550 mA | - | Shielded | 500mOhm Max | 10 @ 2.52MHz | 22MHz | - | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-1R8M-TFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Obsolete | Wirewound | - | 1.8 µH | ±20% | 900 mA | - | Shielded | 160mOhm Max | 10 @ 7.96MHz | 70MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-220K-TINDUCTOR MOLDED WOUND SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Active | Wirewound | - | 22 µH | ±10% | 370 mA | - | Shielded | 900mOhm Max | 10 @ 2.52MHz | 18MHz | - | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-4R7M-TFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Obsolete | Wirewound | - | 4.7 µH | ±20% | 650 mA | - | Shielded | 270mOhm Max | 10 @ 7.96MHz | 35MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-1R0M-TFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Obsolete | Wirewound | - | 1 µH | ±20% | 1.05 A | - | Shielded | 110mOhm Max | 10 @ 7.96MHz | 100MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-2R2MFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Obsolete | Wirewound | - | 2.2 µH | ±20% | 850 mA | - | Shielded | 180mOhm Max | 10 @ 7.96MHz | 65MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-4R7K-TINDUCTOR MOLDED WOUND SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Active | Wirewound | - | 4.7 µH | ±10% | 650 mA | - | Shielded | 270mOhm Max | 10 @ 7.96MHz | 35MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-181M-TFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Obsolete | Wirewound | - | 180 µH | ±20% | 120 mA | - | Shielded | 7.5Ohm Max | 20 @ 796kHz | 6.5MHz | - | -40°C ~ 125°C | 796 kHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-560M-TFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Obsolete | Wirewound | - | 56 µH | ±20% | 240 mA | - | Shielded | 2.2Ohm Max | 10 @ 2.52MHz | 11MHz | - | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-5R6MFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Obsolete | Wirewound | - | 5.6 µH | ±20% | 650 mA | - | Shielded | 300mOhm Max | 10 @ 7.96MHz | 30MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-1R5MFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Obsolete | Wirewound | - | 1.5 µH | ±20% | 950 mA | - | Shielded | 150mOhm Max | 10 @ 7.96MHz | 80MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-100K-TINDUCTOR MOLDED WOUND SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Active | Wirewound | - | 10 µH | ±10% | 550 mA | - | Shielded | 500mOhm Max | 10 @ 2.52MHz | 22MHz | - | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-220KINDUCTOR MOLDED WOUND SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Active | Wirewound | - | 22 µH | ±10% | 370 mA | - | Shielded | 900mOhm Max | 10 @ 2.52MHz | 18MHz | - | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-680K-TINDUCTOR MOLDED WOUND SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Active | Wirewound | - | 68 µH | ±10% | 220 mA | - | Shielded | 2.6Ohm Max | 10 @ 2.52MHz | 10MHz | - | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-220MFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Obsolete | Wirewound | - | 22 µH | ±20% | 370 mA | - | Shielded | 900mOhm Max | 10 @ 2.52MHz | 18MHz | - | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-1R8KINDUCTOR MOLDED WOUND SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Active | Wirewound | - | 1.8 µH | ±10% | 900 mA | - | Shielded | 160mOhm Max | 10 @ 7.96MHz | 70MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-1R2M-TFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Tape & Reel (TR) | Obsolete | Wirewound | - | 1.2 µH | ±20% | 1 A | - | Shielded | 120mOhm Max | 10 @ 7.96MHz | 90MHz | - | -40°C ~ 125°C | 7.96 MHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
|
AISM-1812H-101MFIXED INDUCTOR SMD |
0 |
|
|
AISM-1812H | 1812 (4532 Metric) | Bulk | Obsolete | Wirewound | - | 100 µH | ±20% | 180 mA | - | Shielded | 4Ohm Max | 20 @ 796kHz | 8MHz | - | -40°C ~ 125°C | 796 kHz | - | Surface Mount | 1812 | 0.165" L x 0.126" W (4.20mm x 3.20mm) | 0.134" (3.40mm) |
Kategorieübersicht
Feste Induktoren Produkte und Auswahlhilfe
Feste Induktoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Feste Induktoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Feste Induktoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.