Durchführungskondensatoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Kapazität | Toleranz | Spannung - Nenn | Strom | Gleichstromwiderstand (DCR) (max.) | Betriebstemperatur | Einfügungsdämpfung | Temperaturkoeffizient | Bewertungen | Montageart | Größe/Abmessung | Höhe (max.) | Gewindegröße |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SFSWG5000680ZC0SOLDER MOUNT HERMETIC EMI FILTER |
100 |
|
|
SFSWG | Axial | Bulk | Active | 68 pF | -20%, +80% | 500V | 5 A | - | -55°C ~ 125°C | 2dB @ 100MHz | C0G, NP0 | - | Through Hole | 0.156" Dia x 0.110" L (3.96mm x 2.79mm) | - | - |
|
SFSWG5000470ZC0SOLDER MOUNT HERMETIC EMI FILTER |
100 |
|
|
SFSWG | Axial | Bulk | Active | 47 pF | -20%, +80% | 500V | 5 A | - | -55°C ~ 125°C | 1dB @ 100MHz | C0G, NP0 | - | Through Hole | 0.156" Dia x 0.110" L (3.96mm x 2.79mm) | - | - |
|
SFSWG5000151MC0SOLDER MOUNT HERMETIC EMI FILTER |
100 |
|
|
SFSWG | Axial | Bulk | Active | 150 pF | ±20% | 500V | 5 A | - | -55°C ~ 125°C | 7dB @ 100MHz | C0G, NP0 | - | Through Hole | 0.156" Dia x 0.110" L (3.96mm x 2.79mm) | - | - |
|
SFSWG5000331MC0SOLDER MOUNT HERMETIC EMI FILTER |
100 |
|
|
SFSWG | Axial | Bulk | Active | 330 pF | ±20% | 500V | 5 A | - | -55°C ~ 125°C | 13dB @ 100MHz | C0G, NP0 | - | Through Hole | 0.156" Dia x 0.110" L (3.96mm x 2.79mm) | - | - |
|
SFSWG5000221MC0SOLDER MOUNT HERMETIC EMI FILTER |
90 |
|
|
SFSWG | Axial | Bulk | Active | 220 pF | ±20% | 500V | 5 A | - | -55°C ~ 125°C | 10dB @ 100MHz | C0G, NP0 | - | Through Hole | 0.156" Dia x 0.110" L (3.96mm x 2.79mm) | - | - |
|
SFSWG5000471MC0SOLDER MOUNT HERMETIC EMI FILTER |
100 |
|
|
SFSWG | Axial | Bulk | Active | 470 pF | ±20% | 500V | 5 A | - | -55°C ~ 125°C | 16dB @ 100MHz | C0G, NP0 | - | Through Hole | 0.156" Dia x 0.110" L (3.96mm x 2.79mm) | - | - |
|
B85321A2502Y160CAP FEEDTHRU |
9 |
|
|
B85321 | Axial - Threaded Terminals | Bulk | Active | 2500 pF | ±20% | 600V | 16 A | - | -40°C ~ 85°C | 80dB @ 100MHz | - | - | Bolt Mount | 0.630" Dia x 1.772" L (16.00mm x 45.00mm) | - | - |
|
B85321A2204A250CAP FEEDTHRU |
10 |
|
|
B85321 | Axial - Threaded Terminals | Bulk | Active | 0.1 µF | ±20% | 600V | 25 A | - | -40°C ~ 85°C | 100dB @ 100MHz | - | - | Bolt Mount | 1.181" Dia x 3.189" L (30.00mm x 81.00mm) | - | - |
|
B85321A2405A101CAP FEEDTHRU |
3 |
|
|
B85321 | Axial - Threaded Terminals | Bulk | Active | 2 µF | ±20% | 600V | 100 A | - | -40°C ~ 85°C | 100dB @ 100MHz | - | - | Bolt Mount | 2.165" Dia x 3.937" L (55.00mm x 100.00mm) | - | - |
|
DGA6114DIGIWAVE DUAL RG6 FEED THRU BUSH |
998 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DGA6113DIGIWAVE SINGLE RG6 FEED THRU BU |
998 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DGA6115DIGIWAVE SINGLE RG6 FEED THRU BU |
998 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DGA6112DIGIWAVE DUAL RG6 FEED THRU BUSH |
998 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
YFF21AC1H101MT0Y0NAUTOMOTIVE GRADE FEED THROUGH FI |
0 |
|
|
YFF-AC | 0805 (2012 Metric), 4 PC Pad | Tape & Reel (TR) | Active | 100 pF | ±20% | 50V | 1 A | - | -55°C ~ 125°C | 30dB @ 1GHz ~ 5GHz | - | AEC-Q200 | Surface Mount | 0.079" L x 0.049" W (2.00mm x 1.25mm) | 0.039" (1.00mm) | - |
|
|
4300-013LFCAP FEEDTHRU 50V AXIAL |
8 |
|
|
4300 | Axial | Bulk | Active | - | - | 50V | 5 A | - | -55°C ~ 125°C | 42dB @ 100MHz | - | - | - | 0.156" Dia x 0.110" L (3.96mm x 2.79mm) | - | - |
|
4402-018LFCAP FEEDTHRU 50V AXIAL |
0 |
|
|
4402 | Axial, Bushing | Tray | Active | - | - | 50V | 10 A | - | -55°C ~ 125°C | 47dB @ 100MHz | - | - | - | 0.156" Dia x 0.333" L (3.96mm x 8.45mm) | - | 6-32 |
|
SBSMC5000683MXTCAP FEEDTHRU 0.068UF 500V 2220 |
0 |
|
|
SBSM | 2220 (5750 Metric), 3 PC Pad | Tape & Reel (TR) | Active | 0.068 µF | ±20% | 500V | 20 A | - | -55°C ~ 125°C | 43dB @ 100MHz | X7R | - | Surface Mount | 0.224" L x 0.197" W (5.70mm x 5.00mm) | 0.133" (3.38mm) | - |
|
2425-001-X5U0-102AALFCAP FEEDTHRU 200V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | - | - | 200V | 20 A | - | -55°C ~ 85°C | - | X5U | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
|
2499-003-X5W0-103ZLFCAP FEEDTHRU 0.01UF 500V AXIAL |
0 |
|
|
2499 | Axial, Bushing | Bulk | Active | 10000 pF | -20%, +80% | 500V | 20 A | - | -55°C ~ 85°C | 35dB @ 100MHz | X5W | - | - | 0.250" Dia x 0.468" L (6.35mm x 11.89mm) | - | 12-28 |
|
|
4400-097LFCAP FEEDTHRU 100V AXIAL |
0 |
|
|
4400 | Axial, Bushing | Bulk | Active | - | - | 100V | 10 A | - | -55°C ~ 125°C | 25dB @ 100MHz | - | - | - | 0.157" Dia x 0.276" L (4.00mm x 7.00mm) | - | M3x0.5 |
Kategorieübersicht
Durchführungskondensatoren Produkte und Auswahlhilfe
Durchführungskondensatoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Durchführungskondensatoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Durchführungskondensatoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.