Durchführungskondensatoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Kapazität | Toleranz | Spannung - Nenn | Strom | Gleichstromwiderstand (DCR) (max.) | Betriebstemperatur | Einfügungsdämpfung | Temperaturkoeffizient | Bewertungen | Montageart | Größe/Abmessung | Höhe (max.) | Gewindegröße |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
4702-009TLFCAP FEEDTHRU 300PF 500V PILL |
0 |
|
|
4702 | Pill, Square | Tape & Reel (TR) | Active | 300 pF | -20%, +80% | 500V | 20 A | - | -55°C ~ 125°C | - | - | - | - | 0.315" L x 0.090" W (8.00mm x 2.29mm) | 0.095" (2.42mm) | - |
|
DB045120WE12236BJ1CAP 1200PF KVP R85 3668 |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
B85121A2105A101CAP FEEDTHRU 1UF 20% 600V AXIAL |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Active | 1 µF | ±20% | 600V | 100 A | - | -40°C ~ 85°C | 85dB @ 100MHz | - | - | - | 2.165" Dia x 1.181" L (55.00mm x 30.00mm) | - | M8 |
|
B85121A2105A201CAP FEEDTHRU 1UF 20% 600V AXIAL |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Active | 1 µF | ±20% | 600V | 200 A | - | -40°C ~ 85°C | 85dB @ 100MHz | - | - | - | 2.165" Dia x 1.181" L (55.00mm x 30.00mm) | - | M10 |
|
B85121A105B250CAP FEEDTHRU 1UF 20% 160V |
0 |
|
|
B85121 | Axial, Bushing | Bulk | Obsolete | 1 µF | ±20% | 160V | 25 A | - | -40°C ~ 85°C | 85dB @ 100MHz | - | - | Bolt Mount | 0.787" Dia x 2.362" L (20.00mm x 60.00mm) | - | M12 |
|
B85111A2503B500CAP FEEDTHRU 0.05UF 20% 600V |
0 |
|
|
B85111 | Axial - Threaded Terminals | Bulk | Obsolete | 0.05 µF | ±20% | 600V | 50 A | - | -40°C ~ 85°C | 60dB @ 100MHz | - | - | Bolt Mount | 0.945" Dia x 1.772" L (24.00mm x 45.00mm) | - | M6 |
|
B85121A2103B250CAP FEEDTHRU 0.01UF 20% 600V |
0 |
|
|
B85121 | Axial, Bushing | Bulk | Obsolete | 10000 pF | ±20% | 600V | 25 A | - | -40°C ~ 85°C | - | - | - | Bolt | 0.787" Dia x 2.362" L (20.00mm x 60.00mm) | - | M12 |
|
B85121A2103C160CAP FEEDTHRU 10000PF 600V AXIAL |
0 |
|
|
B85121 | Axial, Bushing | Bulk | Obsolete | 10000 pF | ±20% | 600V | 16 A | - | -40°C ~ 85°C | 55dB @ 100MHz | - | - | - | 0.630" Dia x 1.181" L (16.00mm x 30.00mm) | - | M10x0.75 |
|
B85121A2104A250CAP FEEDTHRU 0.1UF 20% 600V |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Obsolete | 0.1 µF | ±20% | 600V | 25 A | - | -40°C ~ 85°C | 60dB @ 100MHz | - | - | Bolt Mount | 0.787" Dia x 2.362" L (20.00mm x 60.00mm) | - | M6 |
|
B85121A2104A750CAP FEEDTHRU 0.1UF 20% 600V |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Obsolete | 0.1 µF | ±20% | 600V | 75 A | - | -40°C ~ 85°C | 60dB @ 100MHz | - | - | Bolt Mount | 1.181" Dia x 2.165" L (30.00mm x 55.00mm) | - | M6 |
|
B85121A2105A250CAP FEEDTHRU 1UF 20% 600V AXIAL |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Active | 1 µF | ±20% | 600V | 25 A | - | -40°C ~ 85°C | 85dB @ 100MHz | - | - | - | 1.181" Dia x 2.165" L (30.00mm x 55.00mm) | - | M6 |
|
B85121A2503B250CAP FEEDTHRU 0.05UF 600V AXIAL |
0 |
|
|
B85121 | Axial, Bushing | Bulk | Active | 0.05 µF | ±20% | 600V | 25 A | - | -40°C ~ 85°C | 60dB @ 100MHz | - | - | - | 0.787" Dia x 2.362" L (20.00mm x 60.00mm) | - | M12x0.75 |
|
B85121A2503C160CAP FEEDTHRU 0.05UF 600V AXIAL |
0 |
|
|
B85121 | Axial, Bushing | Bulk | Active | 0.05 µF | ±20% | 600V | - | - | -40°C ~ 85°C | - | - | - | - | 0.630" Dia x 1.181" L (16.00mm x 30.00mm) | - | M10x0.75 |
|
B85121A4252C160CAP FEEDTHRU 2500PF 600V AXIAL |
0 |
|
|
B85121 | Axial, Bushing | Bulk | Active | 2500 pF | ±20% | 600V | - | - | -40°C ~ 85°C | 45dB @ 100MHz | - | - | - | 0.630" Dia x 1.181" L (16.00mm x 30.00mm) | - | M10x0.75 |
|
B85321A2502V160CAP FEEDTHRU |
0 |
|
|
B85321 | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
B85121A2205A101CAP FEEDTHRU 2UF 600V AXIAL |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Obsolete | 2 µF | - | 600V | 100 A | - | -40°C ~ 85°C | 90dB @ 100MHz | - | - | - | 2.165" Dia x 2.362" L (55.00mm x 60.00mm) | - | M8 |
|
B85121A2205A201CAP FEEDTHRU 2UF 600V AXIAL |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Obsolete | 2 µF | - | 600V | 200 A | - | -40°C ~ 85°C | 90dB @ 100MHz | - | - | - | 2.165" Dia x 2.362" L (55.00mm x 60.00mm) | - | M10 |
|
B85121A2205A630CAP FEEDTHRU 2UF 600V AXIAL |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Obsolete | 2 µF | - | 600V | 63 A | - | -40°C ~ 85°C | 90dB @ 100MHz | - | - | - | 2.165" Dia x 2.362" L (55.00mm x 60.00mm) | - | M6 |
|
B85121A2475A101CAP FEEDTHRU 4.7UF 600V AXIAL |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Obsolete | 4.7 µF | - | 600V | 100 A | - | -40°C ~ 85°C | 90dB @ 100MHz | - | - | - | 2.165" Dia x 2.362" L (55.00mm x 60.00mm) | - | M8 |
|
B85121A2475A201CAP FEEDTHRU 4.7UF 600V AXIAL |
0 |
|
|
B85121 | Axial - Threaded Terminals | Bulk | Obsolete | 4.7 µF | - | 600V | 200 A | - | -40°C ~ 85°C | 90dB @ 100MHz | - | - | - | 2.165" Dia x 2.362" L (55.00mm x 60.00mm) | - | M10 |
Kategorieübersicht
Durchführungskondensatoren Produkte und Auswahlhilfe
Durchführungskondensatoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Durchführungskondensatoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Durchführungskondensatoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.