Durchführungskondensatoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Kapazität | Toleranz | Spannung - Nenn | Strom | Gleichstromwiderstand (DCR) (max.) | Betriebstemperatur | Einfügungsdämpfung | Temperaturkoeffizient | Bewertungen | Montageart | Größe/Abmessung | Höhe (max.) | Gewindegröße |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
2425-003-X7R0-102MCAP FEEDTHRU 1000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | ±20% | 100V | 20 A | - | -55°C ~ 125°C | - | X7R | - | Chassis Mount | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-003-X7R0-102MLFCAP FEEDTHRU 1000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | ±20% | 100V | 20 A | - | -55°C ~ 125°C | - | X7R | - | Chassis Mount | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-003-X7U0-102AACAP FEEDTHRU 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | - | - | 100V | 20 A | - | -55°C ~ 125°C | - | X7U | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-003-X7U0-102AALFCAP FEEDTHRU 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | - | - | 100V | 20 A | - | -55°C ~ 125°C | - | X7U | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-003-X7U0-102PCAP FEEDTHRU 1000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | 0%, +100% | 100V | 20 A | - | -55°C ~ 125°C | - | X7U | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-003-X7U0-102PLFCAP FEEDTHRU 1000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | 0%, +100% | 100V | 20 A | - | -55°C ~ 125°C | - | X7U | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X5U0-102MCAP FEEDTHRU 1000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | ±20% | 100V | 20 A | - | -55°C ~ 85°C | 20dB @ 100MHz | X5U | - | Chassis Mount | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X5U0-102MLFCAP FEEDTHRU 1000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | ±20% | 100V | 20 A | - | -55°C ~ 85°C | 20dB @ 100MHz | X5U | - | Chassis Mount | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X5U0-102PCAP FEEDTHRU 1000PF 200V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | 0%, +100% | 200V | 20 A | - | -55°C ~ 85°C | - | X5U | - | Chassis Mount | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X5U0-102PLFCAP FEEDTHRU 1000PF 200V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | 0%, +100% | 200V | 20 A | - | -55°C ~ 85°C | - | X5U | - | Chassis Mount | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X5W0-502MCAP FEEDTHRU 5000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 5000 pF | ±20% | 100V | 20 A | - | -55°C ~ 85°C | 30dB @ 100MHz | X5W | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X5W0-502MLFCAP FEEDTHRU 5000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 5000 pF | ±20% | 100V | 20 A | - | -55°C ~ 85°C | 30dB @ 100MHz | X5W | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X7R0-101MCAP FEEDTHRU 100PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 100 pF | ±20% | 100V | 20 A | - | -55°C ~ 125°C | - | X7R | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X7R0-102PCAP FEEDTHRU 1000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 1000 pF | 0%, +100% | 100V | 20 A | - | -55°C ~ 125°C | - | X7R | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-018-X7R0-102ZCAP FEEDTHRU 1000PF 100V |
0 |
|
|
2425 | - | Bulk | Active | 1000 pF | -20%, +80% | 100V | 20 A | - | -55°C ~ 125°C | - | X7R | - | - | - | - | - |
|
2425-018-X7R0-102ZLFCAP FEEDTHRU 1000PF 100V |
0 |
|
|
2425 | - | Bulk | Active | 1000 pF | -20%, +80% | 100V | 20 A | - | -55°C ~ 125°C | - | X7R | - | - | - | - | - |
|
2425-018-X7W0-502PCAP FEEDTHRU 5000PF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing, 1 Turret Lead | Bulk | Active | 5000 pF | 0%, +100% | 100V | 20 A | - | -55°C ~ 125°C | - | X7W | - | - | 0.187" Dia x 0.359" L (4.75mm x 9.12mm) | - | 8-32 |
|
2425-601-X5W0-103ZCAP FEEDTHRU 0.01UF 100V AXIAL |
0 |
|
|
2425 | Axial, Bushing | Bulk | Active | 10000 pF | -20%, +80% | 100V | 20 A | - | -55°C ~ 85°C | 35dB @ 100MHz | X5W | - | - | 0.187" Dia x 0.470" L (4.75mm x 11.94mm) | - | 8-32 |
|
2430-008-X5F0-102MCAP FEEDTHRU 1000PF 200V AXIAL |
0 |
|
|
2430 | Axial, Bushing | Bulk | Active | 1000 pF | ±20% | 200V | - | - | -55°C ~ 85°C | - | X5F | - | - | 0.156" Dia x 0.350" L (3.96mm x 8.90mm) | - | 6-32 |
|
2430-008-X5F0-102MLFCAP FEEDTHRU 1000PF 200V AXIAL |
0 |
|
|
2430 | Axial, Bushing | Bulk | Active | 1000 pF | ±20% | 200V | - | - | -55°C ~ 85°C | - | X5F | - | - | 0.156" Dia x 0.350" L (3.96mm x 8.90mm) | - | 6-32 |
Kategorieübersicht
Durchführungskondensatoren Produkte und Auswahlhilfe
Durchführungskondensatoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Durchführungskondensatoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Durchführungskondensatoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.
