Elektrische, Spezialsicherungen
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Paket/Gehäuse | Verpackung | Produktstatus | Montageart | Sicherungstyp | Stromstärke (Ampere) | Spannungsstärke - Wechselstrom | Spannungsstärke - Gleichstrom | Reaktionszeit | Anwendungen | Funktionen | Klasse | Zulassungsstelle | Betriebstemperatur | Ausschaltvermögen bei Nennspannung | Größe/Abmessung | Klasse | Qualifizierung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SCF5432-30-03FUSE TRIGGERABLE 30A 62V 3 CELL |
9,036 |
|
|
SCF5432 | Nonstandard SMD | Tape & Reel (TR) | Active | Surface Mount | Board Mount | 30A | - | 62 VDC | Fast Blow | Battery Protection | 9.9 ~ 13.5V Triggerable | - | cURus | -20°C ~ 60°C | 80A | 0.213" L x 0.126" W x 0.053" H (5.40mm x 3.20mm x 1.35mm) | - | - |
|
SCF5432-30-13FUSE TRIGGERABLE 30A 62V 13 CELL |
9,995 |
|
|
SCF5432 | Nonstandard SMD | Tape & Reel (TR) | Active | Surface Mount | Board Mount | 30A | - | 62 VDC | Fast Blow | Battery Protection | 45.2 ~ 58.5V Triggerable | - | - | -20°C ~ 60°C | 80A | 0.213" L x 0.126" W x 0.053" H (5.40mm x 3.20mm x 1.35mm) | - | - |
|
C308F250MA-TR13X8.4FA, CERAMIC FUSE, 250MA, TR |
4,931 |
|
|
C308F | Cartridge, Non-Standard | Tape & Reel (TR) | Active | Surface Mount | Cartridge, Ceramic | 250mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.120" Dia x 0.343" L (3.05mm x 8.70mm) | - | - |
|
C308F63MA-TRFUSE CERM 63MA 250VAC/VDC |
337 |
|
|
C308F | Cartridge, Non-Standard | Tape & Reel (TR) | Active | Surface Mount | Cartridge, Ceramic | 63mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.120" Dia x 0.343" L (3.05mm x 8.70mm) | - | - |
|
048103.5HFUSE INDICATING 3.5A 125VAC/VDC |
767 |
|
|
481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 3.5A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
048107.5HXPFUSE INDICATING 7.5A 125VAC/VDC |
190 |
|
|
481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 7.5A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
0481005.HXPFUSE INDICATING 5A 125VAC/VDC |
115 |
|
|
481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 5A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
C308F160MA-TR13X8.4FA, CERAMIC FUSE, 160MA, TR |
1,205 |
|
|
C308F | Cartridge, Non-Standard | Tape & Reel (TR) | Active | Surface Mount | Cartridge, Ceramic | 160mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.120" Dia x 0.343" L (3.05mm x 8.70mm) | - | - |
|
EAC10-50FUSE 500V 50A CARTRIDGE |
274 |
|
|
EAC10 | Cartridge, Non-Standard | Tray | Active | Requires Holder | Cartridge | 50A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | - | - | 2kA | 0.402" Dia x 1.283" L (10.20mm x 32.60mm) | - | - |
|
C308F-V-80MA-TR1FUSE CERAMIC 80MA 250VAC/VDC |
1,424 |
|
|
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 80mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
C308F-V-125MA-TR1FUSE CERAMIC 125MA 250VAC/VDC |
1,280 |
|
|
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 125mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
C308F-V-160MA-TR1FUSE CERAMIC 160MA 250VAC/VDC |
303 |
|
|
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 160mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
EAC10-40FUSE 500V 40A CARTRIDGE |
448 |
|
|
EAC10 | Cartridge, Non-Standard | Tray | Active | Requires Holder | Cartridge | 40A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | - | - | 2kA | 0.402" Dia x 1.283" L (10.20mm x 32.60mm) | - | - |
|
EAC10-63FUSE 500V 63A CARTRIDGE |
309 |
|
|
EAC10 | Cartridge, Non-Standard | Tray | Active | Requires Holder | Cartridge | 63A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | - | - | 2kA | 0.402" Dia x 1.283" L (10.20mm x 32.60mm) | - | - |
|
C308F80MA-TRFUSE CERAMIC 80MA 250VAC/VDC |
1,131 |
|
|
C308F | Cartridge, Non-Standard | Tape & Reel (TR) | Active | Surface Mount | Cartridge, Ceramic | 80mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.120" Dia x 0.343" L (3.05mm x 8.70mm) | - | - |
|
C308F-V-100MA-TR1FUSE CERAMIC 100MA 250VAC/VDC |
1,425 |
|
|
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 100mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
0259001.TFUSE BRD MNT 1A 125VAC/VDC RAD |
577 |
|
|
259 | Radial, Can, Horizontal | Bulk | Active | Through Hole | Board Mount | 1A | 125 VAC | 125 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | Baseefa, UR | -55°C ~ 90°C | 50A AC, 300A DC | 0.315" Dia x 0.512" L (8.00mm x 13.00mm) | - | - |
|
C308F-V-250MA-TR1FUSE CERAMIC 250MA 250VAC/VDC |
1,418 |
|
|
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 250mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
0259.500TFUSE BRD MNT 500MA 125VAC/VDC |
472 |
|
|
259 | Radial, Can, Horizontal | Bulk | Active | Through Hole | Board Mount | 500mA | 125 VAC | 125 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | Baseefa, UR | -55°C ~ 90°C | 50A AC, 300A DC | 0.315" Dia x 0.512" L (8.00mm x 13.00mm) | - | - |
|
ITV9550L2030MRFUSE BATTERY PROTECTOR 20V 45A |
961 |
|
|
POLYSWITCH®, ITV9550 | Nonstandard SMD | Tape & Reel (TR) | Active | Surface Mount | Board Mount | 30A | - | 62 VDC | Fast Blow | Battery Protection | 14 ~ 23.4V Triggerable | - | cURus, TUV | -10°C ~ 65°C | 80A | 0.366" L x 0.197" W x 0.079" H (9.30mm x 5.00mm x 2.00mm) | - | - |
Kategorieübersicht
Elektrische, Spezialsicherungen Produkte und Auswahlhilfe
Elektrische, Spezialsicherungen werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Elektrische, Spezialsicherungen nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Elektrische, Spezialsicherungen aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.
