Brückengleichrichter
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Diodentyp | Technologie | Spannung - Spitzensperrspannung (Max) | Strom - Durchschnittlich gleichgerichtet (Io) | Spannung - Vorwärtsspannung (Vf) (Max) @ If | Strom - Sperrleck @ Vr | Betriebstemperatur | Klasse | Qualifizierung | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
M50100SB400BRIDGE RECT 1P 400V 100A MODULE |
5 |
|
|
- | Module | Bulk | Active | Single Phase | Standard | 400 V | 100 A | 1.2 V @ 100 A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | Module |
|
PT100SN16BRIDGE RECT 3P 1.6KV 100A MODULE |
23 |
|
|
- | Module | Bulk | Active | Three Phase | Standard | 1.6 kV | 100 A | 1.35 V @ 100 A | 10 mA @ 1600 V | -40°C ~ 150°C (TJ) | - | - | Chassis Mount | Module |
|
M50100SB1200BRIDGE RECT 1P 1.2KV 100A MODULE |
15 |
|
|
- | Module | Bulk | Active | Single Phase | Standard | 1.2 kV | 100 A | 1.2 V @ 100 A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | Module |
|
M50100TB600BRIDGE RECT 3P 600V 100A MODULE |
7 |
|
|
- | Module | Bulk | Active | Three Phase | Standard | 600 V | 100 A | 1.2 V @ 100 A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | Module |
|
PT200N16BRIDGE RECT 3P 1.6KV 200A MODULE |
24 |
|
|
- | Module | Bulk | Active | Three Phase | Standard | 1.6 kV | 200 A | 1.45 V @ 150 A | 10 mA @ 1600 V | -40°C ~ 150°C (TJ) | - | - | Chassis Mount | Module |
|
M50100TB1600BRIDGE RECT 3P 1.6KV 100A MODULE |
11 |
|
|
- | Module | Bulk | Active | Three Phase | Standard | 1.6 kV | 100 A | 1.2 V @ 100 A | - | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | Module |
|
UG3KB60GBRIDGE RECT 1PHASE 600V 3A D3K |
488 |
|
|
- | 4-ESIP | Tube | Active | Single Phase | Standard | 600 V | 3 A | 1.1 V @ 3 A | 5 µA @ 600 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | D3K |
|
UG4KB100BRIDGE RECT 1PHASE 1KV 4A D3K |
301 |
|
|
- | 4-ESIP | Tube | Active | Single Phase | Standard | 1 kV | 4 A | 1.1 V @ 4 A | 5 µA @ 1000 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | D3K |
|
SDA006-7BRIDGE RECT 3P 75V 215MA SOT-363 |
866 |
|
|
- | 6-TSSOP, SC-88, SOT-363 | Tape & Reel (TR) | Active | Three Phase | Standard | 75 V | 215 mA | 1.25 V @ 150 mA | 2.5 µA @ 75 V | -65°C ~ 150°C (TJ) | - | - | Surface Mount | SOT-363 |
|
B250C800DM-E3/45BRIDGE RECT 1P 400V 900MA DFM |
807 |
|
|
- | 4-EDIP (0.300", 7.62mm) | Tube | Active | Single Phase | Standard | 400 V | 900 mA | 1 V @ 900 mA | 10 µA @ 400 V | -40°C ~ 125°C (TJ) | - | - | Through Hole | DFM |
|
|
DF06-GBRIDGE RECT 1PHASE 600V 1A 4-DF |
443 |
|
|
- | 4-EDIP (0.321", 8.15mm) | Tube | Active | Single Phase | Standard | 600 V | 1 A | 1.1 V @ 1 A | 10 µA @ 600 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | 4-DF |
|
UG6KB100BRIDGE RECT 1PHASE 1KV 6A D3K |
605 |
|
|
- | 4-ESIP | Tube | Active | Single Phase | Standard | 1 kV | 6 A | 1.1 V @ 6 A | 5 µA @ 1000 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | D3K |
|
KBP2M_T0_00101BRIDGE RECT 1PHASE 1KV 2A KBP |
572 |
|
|
- | 4-ESIP, KBP | Tube | Not For New Designs | Single Phase | Standard | 1 kV | 2 A | 1.1 V @ 2 A | 5 µA @ 1000 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | KBP |
|
DF06MA-E3/45BRIDGE RECT 1PHASE 600V 1A DFM |
435 |
|
|
- | 4-EDIP (0.300", 7.62mm) | Tube | Active | Single Phase | Standard | 600 V | 1 A | 1.1 V @ 1 A | 5 µA @ 600 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | DFM |
|
|
DF204-GBRIDGE RECT 1PHASE 400V 2A 4-DF |
239 |
|
|
- | 4-EDIP (0.321", 8.15mm) | Tube | Active | Single Phase | Standard | 400 V | 2 A | 1.1 V @ 2 A | 10 µA @ 400 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | 4-DF |
|
|
KBP210G-BPBRIDGE RECT 1PHASE 1KV 2A GBP |
442 |
|
|
- | 4-SIP, GBP | Bulk | Active | Single Phase | Standard | 1 kV | 2 A | 1.1 V @ 2 A | 10 µA @ 1000 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | GBP |
|
GBU406BRIDGE RECT 1PHASE 600V 4A GBU |
164 |
|
|
- | 4-ESIP | Tube | Active | Single Phase | Standard | 600 V | 4 A | 1.1 V @ 4 A | 5 µA @ 600 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | GBU |
|
|
GBL205BRIDGE RECT 1PHASE 600V 2A GBL |
442 |
|
|
- | 4-SIP, GBL | Tube | Active | Single Phase | Standard | 600 V | 2 A | 1 V @ 2 A | 5 µA @ 600 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | GBL |
|
KBP204G-GBRIDGE RECT 1PHASE 400V 2A KBP |
891 |
|
|
- | 4-SIP, KBP | Bulk | Active | Single Phase | Standard | 400 V | 2 A | 1.1 V @ 2 A | 10 µA @ 400 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | KBP |
|
KBP201G-GBRIDGE RECT 1PHASE 100V 2A KBP |
805 |
|
|
- | 4-SIP, KBP | Bulk | Active | Single Phase | Standard | 100 V | 2 A | 1.1 V @ 2 A | 10 µA @ 100 V | -55°C ~ 150°C (TJ) | - | - | Through Hole | KBP |
Kategorieübersicht
Brückengleichrichter Produkte und Auswahlhilfe
Brückengleichrichter werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Brückengleichrichter nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Brückengleichrichter aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.