Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SSA2-100ASMART CURRENT SENSE SHUNT 100 AM |
0 |
|
|
SSA2 | Module | Bulk | Active | AC/DC | Shunt | 100A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.2% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 510-SC/L, ASIC 500A PANEL MOUNT |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Current | 0.2mA/A | 200kHz | ±0.1% | 0.5% | 14.25V ~ 25.2V | 0.5µs | 48mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
HAX 1000-SSENSOR CURRENT HALL 1000A AC/DC |
0 |
|
|
HAX | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
CR5211-2SENSOR CURRENT MAGNETIC 2A DC |
0 |
|
|
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 2A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
LF 1005-SSENSOR CURRENT HALL 1000A AC/DC |
0 |
|
|
LF | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | 228mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 1005-SSENSOR CURRENT HALL 1000A AC/DC |
0 |
|
|
LT | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | 30mA | -10°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
IN 100-S100A ULTRA ACCURACY |
0 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 100A | 1 | Current | - | DC ~ 2MHz | ±0.00015% | - | ±14.25V ~ 15.75V | 200ns | 420mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 200-S200A ULTRA ACCURACY |
0 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 200A | 1 | Current | - | DC ~ 1.1MHz | ±1.2% | - | ±14.25V ~ 15.75V | 200ns | 420mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 400-S400A ULTRA ACCURACY |
0 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 400A | 1 | Current | - | DC ~ 800kHz | ±0.8% | - | ±14.25V ~ 15.75V | 200ns | 520mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS50UB-10VCURRENT TRANSDUCER 50A |
0 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 500kHz | ±0.0024% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 500-S500A ULTRA ACCURACY |
0 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 500A | 1 | Current | - | DC ~ 520kHz | ±0.0002% | - | ±14.25V ~ 15.75V | 1µs | 1.19A (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 1200-S1200A ULTRA ACCURACY |
0 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 1200A | 1 | Current | - | DC ~ 440kHz | ±0.0002% | - | ±14.25V ~ 15.75V | 1µs | 1.12A (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
MCS1802GS-20-Z3.3V, LINEAR HALL-EFFECT CURRENT |
2 |
|
|
- | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 20A | 1 | Ratiometric, Voltage | 66mV/A | 100kHz | ±0.5% | ±2.5% | 3V ~ 3.6V | 5µs | 10.5mA | -40°C ~ 125°C (TJ) | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
L08P100D15IPVSENSOR |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HO 240-P-0100SENSOR CURRENT HALL 240A AC/DC |
2 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 240A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CR9321-ACASENSOR CURRENT SWITCH 100A SCR |
0 |
|
|
CR9300 | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 100A | 1 | SCR | - | 50Hz ~ 400Hz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
HOYS 100-S-0100100 A OPEN LOOP BUS BAR MOUNT |
0 |
|
|
HOYS-S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 8mV/A | DC ~ 180kHz | ±0.75% | ±1.25% | 4.5V ~ 5.5V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HOYS 200-S-0100200A OPEN LOOP BUS BAR MOUNT |
0 |
|
|
HOYS-S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 4mV/A | DC ~ 180kHz | ±0.75% | ±1.25% | 4.5V ~ 5.5V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
AT 5 B10SENSOR CURRENT XFMR 5A AC |
0 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 0V ~ 10V | - | 50/60Hz | ±0.5% | ±1.5% | Self Powered | 300ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
HOYL 400-S-0100400A 5V OL BUS BAR MOUNT |
0 |
|
|
HOYL-S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | 2mV/A | DC ~ 140kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.