Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ISOBLOCK I-ST-1C (80A 10V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 80A | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (80A 5V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 80A | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (90A 5V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 90A | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (90A 10V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 90A | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
LT 2005-T/SP18TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | 0°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 2005-T/SP22TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±24V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
ISOBLOCK I-ST-1C (100AAC 7AC 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 100A | 1 | Ratiometric, Voltage | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (100A 10V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 100A | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (100A 5V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 100A | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
CPCO-12000-77-SEDC-AC CURRENT PROBE, CLAMP-ON, 1 |
1 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 12000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CV 4-2500/SP1TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CV 4-6000/SP5TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LB 200-S/SP11TRANSDUCER |
0 |
|
|
LB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Current | - | DC ~ 150kHz | ±0.08% | ±0.5% | ±15V | 1µs | - | 20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
HAZ 20000-SBTRANSDUCER |
0 |
|
|
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20000A | 1 | Analog Voltage | - | DC ~ 3kHz | ±0.5% | ±1% | ±15V | 10µs | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAZ 20000-SBITRANSDUCER |
0 |
|
|
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20000A | 1 | Current | - | DC ~ 3kHz | ±0.5% | ±1% | ±15V | 10µs | 50mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAZ 20000-SRI/SP1TRANSDUCER |
0 |
|
|
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20000A | 1 | Current | - | DC, 15Hz ~ 3kHz | ±0.5% | ±1% | ±15V | 400ms | 50mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CV 4-8000/SP2TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 2000-S/SP20TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CV 4-5000/SP1TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CPCO-4000-160-MADC-AC CURRENT PROBE, CLAMP-ON, 4 |
1 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 26V | 10µs | 80mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.