Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ISOBLOCK I-ST-1C (150MA 5V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 150mA | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (10MA 5V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 10mA | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (3MA 10V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 3mA | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (4MA 10V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 4mA | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (300MA 10V 0.1%)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 300mA | 1 | Open Collector | - | - | - | ±0.1% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
CV 3-200/SP7TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4170-30SENSOR CURRENT XFMR 30A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 30A | 3 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 60mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4170-10SENSOR CURRENT XFMR 10A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 10A | 3 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 60mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4170-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 5A | 3 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 60mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4170-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 15A | 3 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 60mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4170-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 25A | 3 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 60mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CV 3-1000TRANSDUCR VOLTAGE CLOSE LOOP 700 |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4340-20SENSOR CURRENT 10A, 15A, 20A |
0 |
|
|
- | Module | Bulk | Obsolete | AC | Transformer w/Conditioning | 10A, 15A, 20A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz/60Hz | - | ±0.5% | 120V | 150ms | - | -30°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
ISOBLOCK I-ZF (10A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
|
IsoBlock I-ZF | Module | Box | Obsolete | DC | Current Transducer | 10A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (20A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 20A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (50A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 50A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (100A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 100A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (200A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 200A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (200AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (300A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 300A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.