| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DHR 600 C420TRANSDUCER |
0 |
|
|
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600mA | 1 | Current | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
DHR 400 C10TRANSDUCER |
0 |
|
|
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Current Transducer | 400A | 1 | Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
DHR 600 C5TRANSDUCER |
0 |
|
|
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600mA | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
DHR 300 C10TRANSDUCER |
0 |
|
|
DHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
LTC 1000-S/SP28TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-100-U0-I-CAN1-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
0 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 100A | - | CAN Bus | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
DHR 400 C420TRANSDUCER CURRENT 4-20MA OUT |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 1000-SFC/SP1TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-SF/SP26TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1300A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.8% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4120-40SENSOR CURRENT XFMR 40A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 40A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4120-50SENSOR CURRENT XFMR 50A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 50A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4120-10SENSOR CURRENT XFMR 10A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4120-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4120-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4120-20SENSOR CURRENT XFMR 20A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4120-150SENSOR CURRENT XFMR 150A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 150A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4120-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LF 2010-S/SP33TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 2000A | 1 | Current | 0.2mA/A | DC ~ 150kHz | ±0.1% | ±0.3% | ±14.25V ~ 25.2V | 500ns | 48mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP14TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-300-U0-I-CAN1-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
0 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 300A | - | CAN Bus | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.