Schütze (elektromechanisch)
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung | Produktstatus | Montageart | Spulenspannung | Kontaktform | Kontaktleistung (Strom) | Schaltspannung | Funktionen | Anschlussart | Betriebstemperatur | Muss Betriebsspannung | Muss Freigabespannung |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DPE38BLIEC CONTACTOR, 20HP 480V, 24VDC |
29 |
|
|
- | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 38 A | 690VAC, 300VDC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 60°C | 19.2 VDC | 2.4 VDC |
|
AEV250-GAEV250 SERIES 500A DC CONTACTOR |
83 |
|
|
AEV250 | Box | Active | Chassis Mount | 48 ~ 72VDC | SPST-NO (DM) (1 Form X) | 500 A | 1000VDC - Max | - | Stud, Wire Leads | -40°C ~ 85°C | 32 VDC | 18 VDC |
|
IHV50A5ANGRELAY CONTACTOR SPST 50A 24V |
169 |
|
|
IHV50 | Box | Active | Chassis Mount | 24VDC | SPST-NO (DM) (1 Form X) | 50 A | 900VDC - Max | Sealed - Hermetically | Stud, Wire Leads | -40°C ~ 85°C | 16 VDC | 2.4 VDC |
|
IHV50A5ANHRELAY CONTACTOR SPST 50A 24V |
97 |
|
|
IHV50 | Box | Active | Chassis Mount | 24VDC | SPST-NO (DM) (1 Form X) | 50 A | 900VDC - Max | Sealed - Hermetically | Stud, Wire Leads | -40°C ~ 85°C | 16 VDC | 2.4 VDC |
|
|
J7KNA-AR-31 24VSRELAY CONTACTOR 4PST 10A 24V |
120 |
|
|
J7KNA-AR | Bulk | Active | Chassis Mount, DIN Rail | 24VDC | 4PST-3NO/1NC (3 Form A, 1 Form B) | 10 A | 600VAC - Max | Diode | Screw Terminal | -40°C ~ 60°C | - | - |
|
AEV250-MANAEV250 SERIES 500A DC CONTACTOR |
33 |
|
|
AEV250 | Box | Active | Chassis Mount | 12 ~ 24VDC | SPST-NO (DM) (1 Form X) | 500 A | 1000VDC - Max | Auxiliary Contacts | Stud, Wire Leads | -40°C ~ 85°C | 9 VDC | 6 VDC |
|
G7Z-4A DC24RELAY GEN PURP SPST X 4 40A 24V |
398 |
|
|
G7Z | Bulk | Active | Chassis Mount | 24VDC | SPST-NO (1 Form A) x 4 | 40 A | 480VAC - Max | - | Screw Terminal | -25°C ~ 60°C | 18 VDC | 2.4 VDC |
|
DCNEV250-MDC CONTACTOR 24V RELAY 250A 900V |
50 |
|
|
DCNEV250 | Bulk | Active | Chassis Mount | 12 ~ 24VDC | SPST-NO (DM) (1 Form X) | 250 A | 900VDC - Nom | - | Stud, Wire Leads | -40°C ~ 85°C | 9 VDC | 6 VDC |
|
CDC40-24RELAY CONTACTOR 3PST 60A 24V |
81 |
|
|
CDC | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 60 A | - | - | Screw Terminal | - | - | - |
|
B88269X3210C011HVC43 / 250A / 750VDC / 12V COIL |
34 |
|
|
HVC43 | Bulk | Active | Chassis Mount | 12VDC | SPST-NO (1 Form A) | 250 A | 1000VDC - Max | Sealed - Hermetically | Stud, Wire Leads | -40°C ~ 85°C | 9 VDC | 1 VDC |
|
GDP603L120V3P DPC LUG TERM 60A 120VAC |
214 |
|
|
GDP | Bulk | Active | Chassis Mount | 120VAC | 3PST-NO (3 Form A) | 60 A | 277VAC - Nom | - | Box Lug, Quick Connect - 0.250" (6.3mm) | -5°C ~ 40°C | 102 VAC | 24 VAC |
|
DCNEV150-MADC CONTACTOR 150A 900V 36VIN |
53 |
|
|
DCNEV150 | Bulk | Active | Chassis Mount | 9 ~ 36VDC | SPST-NO (DM) (1 Form X) | 150 A | 900VDC - Nom | Auxiliary Contacts | Stud, Wire Leads | -40°C ~ 85°C | 9 VDC | 6 VDC |
|
DCNEV250-MADC CONTACTOR 250A 900V 24VIN |
112 |
|
|
DCNEV250 | Bulk | Active | Chassis Mount | 12 ~ 24VDC | SPST-NO (DM) (1 Form X) | 250 A | 900VDC - Nom | Auxiliary Contacts | Stud, Wire Leads | -40°C ~ 85°C | 9 VDC | 6 VDC |
|
P195BDAP SERIES CONTACTOR |
138 |
|
|
P195 | Bulk | Active | Chassis Mount | 12VDC | SPST-NO (DM) (1 Form X) | 80 A | 1500VDC - Max | Sealed - Hermetically | Stud | -40°C ~ 85°C | 8 VDC | 0.2 VDC |
|
G7Z-4A-02Z-R DC24VRELAY GEN PURP SPST X 4 40A 24V |
94 |
|
|
G7Z | Bulk | Active | Chassis Mount | 24VDC | SPST-NO (1 Form A) x 4 | 40 A | 480VAC - Max | - | Screw Terminal | -25°C ~ 60°C | 18 VDC | 2.4 VDC |
|
DCNEV250-MBDC CONTACTOR 250A 900V 24VIN |
30 |
|
|
DCNEV250 | Bulk | Active | Chassis Mount | 12 ~ 24VDC | SPST-NO (DM) (1 Form X) | 250 A | 900VDC - Nom | Auxiliary Contacts | Stud, Wire Leads | -40°C ~ 85°C | 9 VDC | 6 VDC |
|
3RH21311BB40CONTACTOR RELAY 3NO+1NC DC 24V S |
60 |
|
|
3RH2 | Bulk | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | - | - | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | 19.2 VDC | - |
|
P105CDAP SERIES CONTACTOR |
70 |
|
|
P105 | Bulk | Active | Chassis Mount | 24VDC | SPST-NO (DM) (1 Form X) | 50 A | 1200VDC - Nom | Sealed - Hermetically | Stud | -40°C ~ 65°C | 15 VDC | 0.4 VDC |
|
P105BDAP SERIES CONTACTOR |
30 |
|
|
P105 | Bulk | Active | Chassis Mount | 12VDC | SPST-NO (DM) (1 Form X) | 50 A | 1200VDC - Nom | Sealed - Hermetically | Stud | -40°C ~ 65°C | 7.5 VDC | 0.2 VDC |
|
B88269X2390C011GFC RELAY CONTACTOR 24V 200A |
59 |
|
|
HVC25 | Box | Active | Chassis Mount | 24VDC | SPST-NO (1 Form A) | 200 A | 1000VDC - Max | Sealed - Hermetically | Stud, Wire Leads | -40°C ~ 85°C | 18 VDC | 2 VDC |
Kategorieübersicht
Schütze (elektromechanisch) Produkte und Auswahlhilfe
Schütze (elektromechanisch) werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Schütze (elektromechanisch) nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Schütze (elektromechanisch) aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.