Winkel-, lineare Positionsmessung
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Verpackung/Gehäuse | Serie | Verpackung | Produktstatus | Programmierbar | Zur Messung | Technologie | Drehwinkel – Elektrisch, Mechanisch | Linearbereich | Ausgang | Ausgangssignal | Antriebstyp | Linearität | Widerstand | Widerstandstoleranz | Spannung - Versorgung | Montageart | Anschlussart | Betriebstemperatur | Klasse | Qualifizierung | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
F56105101SENSOR LINEAR 152.4MM CONNECTOR |
0 |
|
|
Rectangular | SLF | Bulk | Obsolete | - | Linear Position | Resistive | - | 0 ~ 152.40mm (0 ~ 6.00") | Resistive | - | Round Shaft | ±1% | 9 kOhms | ±20% | 40V | Chassis Mount | Connector | -65°C ~ 105°C | - | - | - |
|
MLO-POT-300-TLFDISPLACEMENT ENCODER |
0 |
|
|
- | MLO | Bulk | Active | - | Linear Position | Resistive | - | 0 ~ 300.00mm (0 ~ 11.81") | Analog | Clockwise Increase | Linear Potentiometer | ±0.06% | 5 kOhms | ±20% | 42V | - | Connector | -30°C ~ 100°C | - | - | - |
|
PMI210-F110-IU-V1-Y212299INDUCTIVE POSITION (PMI) |
0 |
|
|
- | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
PTX101-0075-111-1110STRING POT |
0 |
|
|
- | * | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
F56204101SENSOR LINEAR 101.6MM CONNECTOR |
0 |
|
|
Rectangular | SLF | Bulk | Obsolete | - | Linear Position | Resistive | - | 0 ~ 101.60mm (0 ~ 4.00") | Resistive | - | Round Shaft | ±1% | 6 kOhms | ±20% | 40V | Chassis Mount | Connector | -65°C ~ 105°C | - | - | - |
|
1059457SENSOR LINEAR 359MM CABLE |
0 |
|
|
Module | MPA | Bulk | Active | - | Linear Position | Magnetoresistive | - | 0 ~ 359.00mm (0 ~ 14.13") | Analog Voltage, 4 ~ 20mA | - | T-Slot | - | - | - | 15V ~ 30V | Chassis Mount | Cable | -20°C ~ 70°C (TA) | - | - | - |
|
RE50L1A103SFERNICE TRANSDUCERS |
0 |
|
|
Cylinder, Wire Leads | REC 50 L | Box | Active | - | Linear Position | Resistive | - | 0 ~ 25.00mm (0 ~ 0.98") | Resistive | - | Round Shaft | ±1% | 10 kOhms | ±20% | - | Custom | Wire Leads | -55°C ~ 125°C | - | - | - |
|
1059456SENSOR LIN 359MM CBL W/CONN |
0 |
|
|
Module | MPA | Bulk | Active | - | Linear Position | Magnetoresistive | - | 0 ~ 359.00mm (0 ~ 14.13") | Analog Voltage, 4 ~ 20mA | - | T-Slot | - | - | - | 15V ~ 30V | Chassis Mount | Cable with Connector | -20°C ~ 70°C (TA) | - | - | - |
|
GHSI-19-013-A-02-20-SSENSOR LINEAR 12.7MM CONNECTOR |
0 |
|
|
Cylinder | GHS-19 | Tube | Active | - | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 12.70mm (0 ~ 0.50") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | - | Chassis Mount | Connector | -20°C ~ 85°C | - | - | - |
|
1140184MAGNETOSTRICTIVE LINEAR ENCODERS |
0 |
|
|
Module | DAX | Bulk | Active | - | Linear Position | Resistive | - | 0 ~ 400.00mm (0 ~ 15.75") | Analog | Clockwise Increase | Flexible Membrane - Linear | - | 500 Ohms | - | 19.2V ~ 28.8V | Chassis Mount | Connector | -40°C ~ 85°C | - | - | - |
|
PMR411A392094WPMCB TRANSDUCERS |
0 |
|
|
- | * | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
RE115L4A103SFERNICE TRANSDUCERS |
0 |
|
|
Module | REC 115 L | Box | Active | - | Linear Position | Resistive | - | 0 ~ 100.00mm (0 ~ 3.94") | Resistive | - | Round Shaft | ±1% | 10 kOhms | ±20% | - | Chassis Mount | Connector | -55°C ~ 125°C | - | - | - |
|
1059459SENSOR LINEAR 395MM CABLE |
0 |
|
|
Module | MPA | Bulk | Active | - | Linear Position | Magnetoresistive | - | 0 ~ 395.00mm (0 ~ 15.55") | Analog Voltage, 4 ~ 20mA | - | T-Slot | - | - | - | 15V ~ 30V | Chassis Mount | Cable | -20°C ~ 70°C (TA) | - | - | - |
|
RE50L1D472SFERNICE TRANSDUCERS |
0 |
|
|
Cylinder, Wire Leads | REC 50 L | Box | Active | - | Linear Position | Resistive | - | 0 ~ 25.00mm (0 ~ 0.98") | Resistive | - | Round Shaft | ±0.1% | 4.7 kOhms | ±20% | - | Custom | Wire Leads | -55°C ~ 125°C | - | - | - |
|
RE50L1D502SFERNICE TRANSDUCERS |
0 |
|
|
Cylinder, Wire Leads | REC 50 L | Box | Active | - | Linear Position | Resistive | - | 0 ~ 25.00mm (0 ~ 0.98") | Resistive | - | Round Shaft | ±0.1% | 5 kOhms | ±20% | - | Custom | Wire Leads | -55°C ~ 125°C | - | - | - |
|
RE50L1D103SFERNICE TRANSDUCERS |
0 |
|
|
Cylinder, Wire Leads | REC 50 L | Box | Active | - | Linear Position | Resistive | - | 0 ~ 25.00mm (0 ~ 0.98") | Resistive | - | Round Shaft | ±0.1% | 10 kOhms | ±20% | - | Custom | Wire Leads | -55°C ~ 125°C | - | - | - |
|
1059458SENSOR LIN 359MM CBL W/CONN |
0 |
|
|
Module | MPA | Bulk | Active | - | Linear Position | Magnetoresistive | - | 0 ~ 359.00mm (0 ~ 14.13") | Analog Voltage, 4 ~ 20mA | - | T-Slot | - | - | - | 15V ~ 30V | Chassis Mount | Cable with Connector | -20°C ~ 70°C (TA) | - | - | - |
|
MLO-POT-360-TLFDISPLACEMENT ENCODER |
0 |
|
|
- | MLO | Bulk | Active | - | Linear Position | Resistive | - | 0 ~ 360.00mm (0 ~ 14.17") | Analog | Clockwise Increase | Linear Potentiometer | ±0.05% | 5 kOhms | ±20% | 42V | - | Connector | -30°C ~ 100°C | - | - | - |
|
RE50L2A502SFERNICE TRANSDUCERS |
0 |
|
|
Cylinder, Wire Leads | REC 50 L | Box | Active | - | Linear Position | Resistive | - | 0 ~ 50.00mm (0 ~ 1.97") | Resistive | - | Round Shaft | ±1% | 5 kOhms | ±20% | - | Custom | Wire Leads | -55°C ~ 125°C | - | - | - |
|
GHSI-19-050-A-02-20-SSENSOR LINEAR 50.8MM CONNECTOR |
0 |
|
|
Cylinder | GHS-19 | Tube | Active | - | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 50.80mm (0 ~ 2.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | - | Chassis Mount | Connector | -20°C ~ 85°C | - | - | - |
Kategorieübersicht
Winkel-, lineare Positionsmessung Produkte und Auswahlhilfe
Winkel-, lineare Positionsmessung werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Winkel-, lineare Positionsmessung nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Winkel-, lineare Positionsmessung aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.